Document N23wgnZaJD025nbrmYpb8aqnb

Skidmore Corporation General Offices and Factory: St. Joseph, Mich Sales and Service Offices Atlanta, Ga. Baltimore, Md. Boston, Mass. Bridgeport, Conn. Buffalo, N. Y. Butte, Mont. Charlotte, N. C. Chattanooga, Tbnn. Chicago, III. Houston, Texas Cincinnati, Ohio Indianapolis, Ind. Cleveland, Ohio Kansas City, Mo. Dallas, Texas Little Rock, Ark. Denver, Colo. Los Angeles, Calip. Des Moines, Iowa Memphis, Tenn. Detroit, Mich. Minneapolis, Minn. Grand Rapids, Mich. New Orleans, La. New York, N. Y. Oklahoma City, Okla. Omaha; Nebr. Philadelphia, Pa. Pittsburgh, Pa. Portland, Orb. Rochester. N. Y. Rockford, III. San Francisco, Calif. Canadian Representatives and Manufacturers--DARLING BROS.. LTD. Seattle. Waeb hrOKANE, Wass St. Louis. Mo. ' "coma. Wash. Tampa, Fu. Toledo, Ohio Tulsa. Okla. 'Varrensbueq, n. y Montreal, Que Skidmore Vacuum Pump Interceptor base gives low water-line operation without pitting. Unit sets directly on floor--no necessity of a concrete base. Occupies small floor spare, simple in design and sturdy, high efficiency Having no close clear ances, valves or gears, the Efficiency Remains Constant. ' Send for Bulletin 6 ' Illustration of Skidmore Condensation Pump The Skidmore Condensation Pump The same high-grade construction as in our Vacuum Pumps: bronze fitted throughout, cast iron" tank, ball bearings. Due to novelty in design, pump has lower water line control than many others which in many instances makes pitting unnecessary. Motor and float mounted high above danger of being submerged. Centrifugal pump is accessible without disturbing piping. Sendfor Bulletin No. 7 Size Capac*y Sq. Ft. H. 10 P. Motor Lb. 20 Lb. Gallons Between Float Stops Calions Per Minute Pumped Wright Inlet Disc. 10# 20/ C 21 2,000 C 22 2.000 C 41 4.000 C 42 4,000 C 61 6,000 C 62 6.000 C 81 8,000 C 82 8,000 CI01 10,000 CI02 10.000 CI21 12,000 C122 12.000 C16I 16.000 CI62 16.000 C261 26.000 C262 26.000 C401 40,000 C402 40.000 a H H H A A Vt P/z A A A A A Va V. i 2 9 9 9 9 9 9 9 9 18 18 18 18 18 18 25 25 25 25 4 2" r 325 4 2" r 350 6 2" r 325 6 2* r 350 8 2* r 325 8 2" \m 350 11 1" I'/,' 325 11 r \A" 350 13 V/f P/.' 44C 13 2A' p/a' 460 16 l'/l" p/a' 46C 16 2A' p/a' 470 22 l'/l" P/a' 460 22 2'A' p/a' 470 35 3' P/2' 495 35 3' P/2' 515 60 y 2 525 60 3* 2' 550 Illustration of a Skidmore Automatic Vacuum Pump 10-in. Vacuum, 10 and 20 lb. Pressure Size of Pump Capacity Sq. Ft. of Radiation Gals, of Water per Min. Motor H. P. 10 Lb. Motor H. P. 20 Lb. Size of Companion Flanges for Returns Size of Discharge to Boiler 0 5,000 8 1 8,000 II 2 16.000 22 3 26.000 35 4 40.000 60 5 65.000 90 6 100.000 150 7 150,000 200 Vs 1 P/2 2 3 5 7V? 10 1 P/t 2 3 5 2A 10 15 p/2' 2* 2" y y y y y 1' i1/.' I1// w 2' r w. . pressure furnished on request. 774 Pumps The Trane Company Let Crosse* Wis. See Unit Heaters, page 696; Heat Cabinets, pages 784-785; Heating Specialties, page 861. BRANCHES IN ALL PRINCIPAL CITIES TRANE PUMPS Circulating Pump Heavy Duty Circulating Pump Condensation Pump, iOO Scries The complete Trane Line of Pumps in cludes condensation pumps, sump pumps, circulating and booster pumps--both low and high pressure for water, brine, or liquids ordinarily encountered in the process industry. All Trane pumps are of the centrifugal pumps. Due to advanced engineering design they develop.higher efficiencies and require smaller motors than the average centrifugal pump. On the smaller pumps three-quarter horsepower motors do work that has always required one. or one-andone-half horsepower. On the larger pumps ll/2 hp. motors do work that ordinarily requires a 10 hp. motor. The condensation pump units are fur nished completely hooked up and ready to install. All electrical equipment is wired according to National Code requirements. Complete data, roughing-in dimensions and capacities for all sizes of pumps will be sent on request. CAPACITIES Radiation in Sq. Ft. Min. Gal. per Min. Max. Unit Complete Pres. at Pump Motor RP. See Notes Approximate Ship. WwLb- in Sq. Ft. Min. Cal. per Min. Max.' Unit Complete at Pump Motor RP. See Notes Approximate Ship. WL. Tib. 410 4000 415 4000 420 4000 430 4000 440 4000 610 6000 615 6000 620 6000 630 6000 640 6000 8)0 8000 815 6tu 8000 8000 830 6000 840 8000 850 8000 1010 10000 1015 10000 1020 10000 1030 10000 1040 10000 1050 10000 6-9 . 6-9 6-9 6-9 6-9 9-12 9-12 9-12 9-12 9-12 12-16 12-16 12-16 12-16 12-16 12-16 15-20 15-20L 15-20 15-20 15-20 15-20 10 15 20 30 40 10 15 20 30 40 10 15 20 30 40 50 10 15 20 30 40 50 / 250 A ' 275 A '275 275 V, 300 8 400 425 425 y. 450 y. 450 A 400 a 425 A 425 V. 450 Vs 450 2 550 425 i 450 . 450 475 V2 s 475 650 1510 1515 1520 1530 1540 1550 2010 2015 2020 2030 2040 2050 2510 2520 2530 2540 2550 Data on larger sizes will be furnished upon request. 775 15000 15000 15000 15000 15000 15000 20000 20000 20000 20000 ' 20000 20000 25000 25000 25000 . 25000 25000 25-30 25-30 25-30 25-30 25-30 25-30 30-40 30-40 30-40 30-40 30-40 30-40 40-50 40-50 40-50 40-50 40-50 10 15 20 30 40 50 10 15 20 30 40 50 10 20 30 40 50 Vt Vs' % 1 2 3` Vs 1 2 2 3 1 Wi 2 3 3 525 550 550 575 625 650 550 575. 575 625 625 650 575 575 600 625 1 650 650 '