Document N23vGm688eQ7xK0g463G6EGLg

f ,c I i -ittii-rrHir jftHnWKi'-- J ]1 ] ] 1 I PYDRAUL. I. FIRE-RESISTANT HYDRAULIC FLUID I SELECTOR OS'N STLCOPCB4073591 1 PYDRAUL " ! \i ,4 stiCgUd) 4 9 Vl ; DSVJ 321942 STLCOPCB4073592 ] ] 3 3 3 3 3 3 3 3 3 3 3 13 THE PYDRAUL SELECTOR ... is designed to put literally at your finger tips all the facts about Pydraul fire-resistant hydraulic fluids--to guide you quickly to the Pydraul fluid that will serve your operation best. Protection from fire for hydraulic operations began with Pydraul. That was in 1951. Pydraul fluids have since served industry with over one billion machine hours of firefree operation. Never during these billion hours of machine operations has a Pydraul fluid contributed to a fire--not even when sprayed from the broken ends of high pres sure hydraulic lines onto white-hot surfaces. New ways are continuously being explored to improve the excellent performance records of Pydraul fluids. The first Pydraul fluid, general-purpose Pydraul F-9, has grown to a family of six, specially tailored, fire-resistant hydraulic fluids and lubricants. Each answers a major but specific hydraulic fluid need for industrial use. In addition to guarding against fire, each Pydraul fluid lubricates as well as premium grade oil. Pydraul fluids have answered the need of virtually every indus trial hydraulic operation, indoors and out-- from the sub-zero, outdoor hydraulic lift operations for refineries and blast furnaces to the low-viscosity fluid demands of high speed, precision machine tools. jpiiau!' umjuHjapppm STLCOPCB4073593 >k~AjLJf'i*/&*is* ma^ -.... PYDRAUL PERFORMANCE The six fire-resistant, premium-lubricating Pydraul fluids offer a widerange of viscosities from which you can select the proper level specified by your hydraulic equipment manufacturer. Whichever Pydraul fluid you select, each provides the same protection against fire, premium lubricity, ease of maintenance, and freedom from corrosive action and foam. Pydraul hydraulic fluids also offer several additional benefits-- REDUCED FIRE INSURANCE RATES Because Pydraul eliminates fire hazards from hydraulic equipment operations, Pydraul reduces the threat of fire to surrounding struc ture and equipment. Insurance premiums for plants using Pydraul, therefore, are often lower than premiums for operations using petroleum oil. LONGER PUMP LIFE Machines that operate on water-based fluids frequently require pump repair or replace ment as often as every two or three months. Machines that use Pydraul hydraulic fluids can operate on the same pump for several years. Pydraul hydraulic fluids give the same long pump life as the finest grade petroleum oil. '" ... " _ . .. " . ? j n' i * j 1 1'ji AHSfljtWfjiJ!W>j,,n wj f jrmbj 4.ii,. DSVV 321944 STLCOPCB4073594 ~ ' - 'Y if riflntip-ri---i**^**^*- n ii n n NO CORROSION PROBLEMS Any metal hydraulic system component in contact with Pydraul will not rust. And Pydraul hydraulic fluids do not lose anti rust properties with use. MAXIMUM EQUIPMENT RESPONSE Pydraul never produces excessive froth or foam during normal operations to interfere with hydraulic equipment response. Because Pydraul hydraulic fluids lubricate as well as premium petroleum oils, Pydraul permits equipment to operate at optimum response capability. INSPECTION AND REPLACEMENT DOWN-TIME ARE VIRTUALLY ELIMINATED Pydraul hydraulic fluids are designed to be permanent. Pydraul fluids do not wear out. Except for normal "make-up" requirements, you never have to add new Pydraul to hydraulic systems. Pydraul eliminates "drain and change" periods; it does not have to be inspected in your system from month to month--or even replaced from year to year. ..... t wia i". DSW 321945 STLCOPCB4073595 i i I't i .i DSW 321946 STLCOPCB4073596 PYOHAUL Low viscosity Pydraul 60 flows freely at --20 F. It retains its properties and thermal stability at tem peratures up to 200 F. In hydraulic operations that require precision flow instantly, Pydraul 60 sup plies smooth operation from machine start to stop; it offers flow-on-demand operation without hydrau lic lag. Pydraul 60 offers excellent, fire-resistant, hydraulic operation with vane, gear and piston pumps in high-speed ma chine tools. FIRE-RESISTANCE TESTS Pydraul fluids protect hydraulic equipment and personnel with permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their more than one billion machine hours of use, Pydraul fluids have been accidentally sprayed over molten metal, through electrical arcs, into flames and sparks--without causingfire. Pydraul fluids have never caused or contrib a uted to an hydraulic fire in any type of equipment. They pass all of the im portant ignition tests for n fire-resistance, as shown by these test results: - 11 T* ill. PHI'S - -............. Physical Properties Appearance j ____________________ j Spec. Gravity 25/25C j Neutralization No. (acidity)(mg KOH/gm) max. [ Moisture (max.) * Viscosity As measured: 100 F. 210 F. "Absolute Saybolts" 100 (SSU X Density) 210 F. F. < \ f 'j \ Pour Point 1 Compressibility X10* sq. in./lb. i ; Bulk Temperature Max. Boiling Point F at 760mm Hg. Coefficient of Thermal Expansion per F. - | j * \ Specific Heat (BTU/lb./6 F.)(@ 77 F.) Thermal Conductivity BTU/hr./ft./ F. Vapor Pressure Hg@200F. \ ? 1 [ Bulk Modulus /Room TempA [ 1000-6000 I \ psi / : j i Solubility in Water Teat High Pressure Spray Test AMS4150B and M1L-F7100. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyacetylene torch, 6000 F. Leer Pressure Spray Test (AMS4150B). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Hat Manifold Test (MILT-7100). Test fluid dripped on tube at 1300 F. : > * j i \ l i j j j ; Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200 F., to test for spontaneous ignition. ? ? \ f DSW 321347 I STLCOPCB4073597 itfuMMt'uM HID' it. i ) t 1 PYDRAUL 159 Pydraul 150 is currently used in more than seven hundred G. P. E. (formerly Askania) regulators to con trol fuel-to-air ratios for blast furnaces, soaking pits, and other similar re lated equipment. Although developed especially for severe cold-weather, out door operations, Pydraul 150 is also used for cer tain missile-launch pro jects and in gears of LOX pumps located in oxygenrich atmospheres at mis sile-fueling sites. Pydraul 150 also performs as an excellent low-viscosity fluid for high-speed ma chine tools. ! --T .. i ... $ i V i DSW 321948 STLCOPCB4073598 STLCOPCB4073599 150 ;A-200 Pydraul A-200 is one of the most widely used, generalpurpose, fire-resistant hy Udraulic fluids in industry. Introduced in 1959, it was the first fire-resistant, r`istraight synthetic hydrau lic fluid to break the"price/ performance barrier." Where protection from fire is the maximum consider ation, Pydraul A-200 offers the lowest cost per gallon of straight synthetic, fireresistant hydraulic fluids. ; ji r i *t if ij SVV 321950 STLCOPCB4073600 i _l i Pbyiicat Prepertitt Appearance Spec. Gravity 25/250C Neutralization No. (acidity) (mg KOH/gm) max. Moisture (max.) Viscnity As measured: 100 F. 210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F. ) | j S { | I | [ Compressibility X10** sq. in./lb. Bulk Temperature Max. Boiling Point F at 760mm Hg. Coefficient of Thermal Expansion per F. Specific Heat (BTU/lb./ F.)(@ 77 F.) Thermal Conductivity BTU/hr./ft/ F. Vapor Pressure Hg @ 200 F. Bulk Modulus/Room Temp.V [ 1000-6000 j \ PS / Solubility in Water Test 1 f \ j 1 [ High Pressure Spray Test AMS-S150B and MIL-F7100. Test fluid sprayed at 100 psi through orifice, passing through flame of . exyacelylene torch, 6000 F. Lew Pressure-Spray Test (AMS-S1S0B). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Hat Manifold Test (MIL-F-7100). Test fluid dripped on tube at 1300 F. Matte* Maul Ignition Teat Test fluid exposed to the surface of aluminum alloy at 1200 F., to test for spontaneous ignition. WT" t . I > 1 DSW 321951 STLCOPCB4073601 $ A 150 A-200 F-9 -\ PYDRAUL F-9 Monsanto introduced Pydraul F-9 as industry's first straight synthetical reresistant hydraulic fluid. Pydraul F-9 rapidly be came the standard against which all other synthetic hydraulic fluids were judged. Today, it is still considered the basis for comparison. Pydraul F-9 is now used in every major type of die-casting ma chine and a wide variety of Other equipment found in the metal-working, glass, and process industries. No other fire-resistant hy draulic fluid has more onthe-line proven perform ance to offer. ::iI f i i i ::f i vi ii t ( t i \ DSW 321952 STLCOPCB4073602 iaHit Physical Prepertiss Appearance Spec. Gravity 25/2SC Neutralization No. (acidity) (mf KOH/gm) mu. Moisture (max.) Viscosity As measured: 100 F. 210 F. "Absolute Saybolts" 100 F. (SSU X Density) 210 F. Pour Point Compressibility X1(H sq. in./lb. Bulk Temperature Mas. Boiling Point F at 760mm Hg. Coefficient of Thermal Expansion per F. Specific Heat (BTU/lb./ F.)(@ 77 F.) Thermal Conductivity BTU/hr./ll./ F. Vapor Pressure Hg@ 200 F. Sulk Modulus /Room TempA ( 1000-6000 I \ psi / Solubility in Water Test High Pressure Spray Test AMS-S1S0B and MIL-FTt00. Test fluid sprayed at 100 psi through orifice. passing through flame of oxyacetylene torch, 6000 F. Low Pressure Spray Tati (AMS-II50B). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of Increase in flame intensity. Hot Menlleld Test (MIL-F-7100). Test fluid dripped on tube at 1300 F. r f i i K l i i i 1 j l V ; I i i \ \ i i c f[ i i i t r f \ i i * Mattan Matal Ignition Tast Test fluid exposed to the surface of aluminum alley at 1200 F.. to test for spontaneous ignition. , J f '&***"* STLCOPCB4073603 150 A-200 F-9 625 PY'DHAUL High viscosity Pydrau! 625 is tailored for ultra-heavyduty hydraulic operations, such as for large industrial presses and pumps. Pydraul 625 is also used as a fire-and - explosion - resist ant air compressor lubri cant. Pydraul 625 can be used in any equipment re quiring an 800 to 1000 SUS oil. I \ * w^wwitn.i lt Y\ DSW 321954 STLCOPCB4073604 h. i -1 Physical Properties Appearance i 1 ] *'j --- IT L'J- n- ij Spec. Gravity 25e/25C Neutralization No. (acidity)<mg KOH/gm) max. Moisture (max.) Viscosity As measured: 100 F. 210 F. "Absolute Saybolts" 100" F. <SSU X Density) 210 F. Pour Point Compressibility X10-* sq. in./lb. Bulk Tempereture Mas. Boiling Point F at 760mm Ng. Coefficient of Thermal Expansion per F. Specific Heat <BTU/lb./ F.)(@ 77 F.) Thermal Conductivity BTU/hr./tL/ F. Vapor Pressure tig 200 F. Bulk Modulus / Room TempA y 1000-6000 j f { `1 5 t t rtj f t i i j ! Solubility in Water Test High Pressure Spray Test AMS4150B and MIL-F7100. Test fluid sprayed at 100 psi through orifice, passing through flame of oxyacetylene torch, 6000 F. Lew Pressure Spray Test <AM$4150B). Test fluid sprayed at low pressure over ignited, oil-soaked rag to determine degree of increase in flame intensity. Het Manifold Test (MIL-F-7100). Test fluid dripped on tube at 1300 F. IT it Motion Metal Cgnitien Test Test fluid exposed to the surface of aluminum alloy at 1200* F., to test for spontaneous ignition. ~~ i jmrnM mmm DSW M1955 STLCOPCB4073605 II 1 150 A-200 F-9 625 PYDRAUL AC A special safety lubricant for air compressors, Pydraul AC offers three important advantages over petroleum oils: safety from flash fires; virtually no valve deposits, and lower maintenance costs. By eliminating combustible mists and minimizing car bonaceous residues, Pydraul AC reduces the threat of compressor fires and explosions. Pydraul AC also reduces compres sor maintenance costs. By eliminating deposits on ex haust valves, in coolers, and in piping, Pydraul AC greatly reduces the costs of compressor down-time and cleaning. These lower maintenance costs alone usually justify Pydraul AC for air compressors. --r 1 DSW 321956 i STLCOPCB4073606 PYDRAUL 625 PYDRAUL A-200 i: PYDR 61 * af Physical Properties 1 Appearance " * ?| * >1 Spec. Gravity 25/75C 8 Clear I Blue | liquid i 1.340 1.360 1 Neutralization No. 1 *| * {acidity)(mg KOH/gm) max. ij 0.15 1 Moisture (max.) 8 0.15^5 f VUcoiity S As measured: 100 F. 1 408.8 SSU M 2100 F. 8 42.1 SSU* | "Absolute Saybolts" 100 F. | 550 SSU | (SSU X Density) 210 F. ?! 50 SSU g Pour Point jj +20 F. Cloudy Blue Liquid Cloudy Blue Liquid 1.340-1.370 1.270-1.300 0.30 0.15% 0.30 070% 625.7 SSU 45.9 SSU 845 SSU 59 SSU +20 F. 225 SSU 43.3 SSU 327 SSU 52 SSU --5 F. Cloudy Blue Liquid 1.415-1.430 0.80-1.10 0.05$ 144 SSU 35.7 SSU 204 SSU 48 SSU +15 F. Cloudy Blue Liquid 1.119-1.135 0.17 0.15% 145.9 SSU 52.5 SSU 163 SSU 56 SSU -55 F. Clou. Blu Liqu 1.008-1 07: 0.1C 60 5 35 5 60.5 5 35 5 --70` __ JH Compressibility X10* If sq. in./lb. J ^ Bulk Temperature Max. y g 2.66 >; 300 F. 2.66 300 F. 2.58 300 F. 278 300 F. 3.13 200 F. 3.0: 200 B Boiling Point J F at 760mm Hg. 1 fj 688 F. 1 Coefficient of Thermal |] __ Expansion per F. H | 0.00040 I Specific Heat | | (BTU/lb./ F.)(@ 77 F.) % 0.32 11 Thermal Conductivity 4 il BTU/hr./ft/ F. g 0.066 | Vapor Pressure | Hg@200F. | g 0.02mm Il i| 11 *1 I BulkModulus/RoomTemp.x [ 1000-6000 IJ \ psi 375.000 Solubility in Water 3 Negligible 724 F. 644 F. 0.00040 0.00041 620 F. 0.00040 617 F. 0.00042 707 o.ooc 0.28 0.32 0.28 0.40 0.4: 0.065 0.067 0.068 0.072 0.04 0.09mm 0.1mm 375,000 387,000 0.2mm 438,000 0.1mm 319,000 0.01 328,[ Negligible Negligible Negligible Negligible Neglig j 1 I _J 1 J 4 am 1 3 1 1 tm | J 1 I Test | PYDRAUL High Pressure Spray Test J Does not AMS-31S0B and MIL-F- ^ flash or 7100. Test fluid sprayed at i ignite up 100 psi through orifice. to 34 passing through flame of 3 feet from oxyacetylene torch.6000 F. 3 orifice. Lew Pressure Sprey Test " Very (AMS-8150B). Test fluid fj slight spreyed et low pressure '1 increase over ignited.oil-soaked rag [j inflame to determine detree ot intensity. increase in flame intensity, a Hat Manifold Teat j Does not (MIL-F-7100). Test fluid j | flash or dripped on tube at 1300 F. 1 burn. PYDRAUL 125 Does not flash or ignite up to 34 feet from orifice. Very slight increase in flame intensity. Does not flash or burn. 3 1 Melten Metal IgniUen Test 3 Does not 1 Test fluid exposed to the j ignite. . J surface of aluminum alloy $ 1 at 1200 F.. to test for g aI spontaneous ignition. f| r Does not ignite. PYDRAUL F-9 Does not flash or ignite up to 34 feet from orifice. No increase in flame intensity. Does not flash or burn. Does not ignite: flashes by spark. PYDRAUL PYDRAUL PYDRA A-200 150 60 Does not flash or ignite up to 34 feet from orifice. Self-ex tinguish ing. Self-e tingui: ing Slight increase in flame intensity. Slight increase in flame intensity. Slight increa in flai inlens Does not flash or burn. Does not ignite. Inter mittent flashing and burning. Little burning in pan below. Does not ignite. Intermitter ffashir and burnir Does r burn after U ing tut Does r ignite. mrnm DSW 321957 STLCOPCB4073607 10,000 $.000 3.000 2.000 Hii 11..500000 J50 d c PYDRAUL VlSCOSmSS Laboratory viscosity measurements of SSU (Saybolt Seconds Universal) are affected by fluid density. Because all petroleum oils used for hydraulic operations have similar densi ties, their measured viscosities can be com pared; however, the densities of synthetic fluids differ from one another and from petroleum oils. To compare viscosities, meas ured viscosities of synthetic fluids must be corrected for density. On the chart below, each curve for a Pydraul fluid shows the viscosity-temperature rela tionship modified for the difference in density of the indicated Pydraul fluid. By comparing these curves with viscosity curves of light, medium, and heavy grades of petroleum oils, it can be seen that Pydraul fluids virtually duplicate viscosities of petroleum oils at normal operating temperatures. c r r r r L_ L 40 CO SO 100 120 140 160 Temperature. Degrees Fahrenheit Absolute Saybolt Viscosity = Measured SSUxDensKy of Pydraul r DSW 321958 STLCOPCB4073608 rrtYifr^iYiriiyiit*mfiiiiM^ 3 .1 :i 3 3 a 3 u h 13 n h CDRIVERTinJG JTO PYDRAUL IS EASY How to convert existing equipment. No matter what type of hydraulic fluid you now use in your equipment, you can easily convert to Pydraul. Virtually every type of hydraulic machinery requiring a fire-resistant hydraulic fluid has been converted to Pydraul. Equipment manufacturers are experienced in converting machinery to Pydraul and should be consulted for their specific recommendations. Some manufacturers will tell you exactly, what seals to change. Most can supply the correct seals. Machines operating on a straight synthetic, fireresistant fluid can be converted to Pydraul without interrupting your production. When converting to Pydraul A-200, Pydraul 625, or Pydraul AC, simply add Pydraul as make-up. To convert to other Pydraul fluids, drain the old fluid and refill with the Pydraul fluid. No flush is necessary. Machines operating on oil or water-based hy draulic fluids require the few simple steps out lined below. These steps are necessary to clean the system of the old fluid and to change to dynamic seals compatible with Pydraul. Check for leaks. Check the entire system before the equipment is shut down for conversion. Mark these leaks for later correction. Drain fluid from the system. Drain the reservoir, lines, and cylinders as completely as possible to remove all of the old fluid. This can sometimes be done by opening unions at low spots in the system and blowing with clean air. i] V|>i. jwii rVISCOSITIES CONVERTING / oBiali-- DSW 321959 STLCOPCB4073609 YiT'rft Tr T `ViTiii'n'i'iiMiiUtiir .Yniiifii . ; 'i *i '' : ; i j .v ,f ! ; i Clean reservoir and filters. Remove interior paint from the reservoir (if painted) by scraping or with a commercial paint remover. Wipe clean with lint-free rags. Clean or change the cartridge in the filter. Check pumps for wear. Replace any part of the pump assembly that shows serious wear. Install seals and packings compatible with Pydraul. Dynamic seals should be changed. Reinforced type hoses are normally satisfactory with Pydraul and need not be replaced if they are in good condition. In operations where severe hose flexing and bending take place, butyl-lined hoses are recommended. Accumulator dia phragms should be made of butyl, Viton, or other materials resistant to Pydraul. ' Reconnect lines. When reconnecting lines, tighten carefully-- particularly those joints that leaked previously. Then fill with Pydraul to the proper level. Start and stop pump. With the hydraulic controls in neutral, start and stop the pump several times, but do not allow the system to reach working pressure, This will help assure that fluid reaches the pump and lubricates it. The pump can then be left on, and the system can be brought to working pressure. Run through the cycle. Run through the cycle several times to use all parts ofthe hydraulic system. Bleed any trapped air through the petcocks or valves. Check the fluid level and add Pydraul if necessary. How to equip new machinery with Pydraul. When ordering new hydraulic equipment, sim ply specify, "For use with Pydraul hydraulic fluid." PWWjl-------- 1\ ' ........ . 1" 1 t ' -i1 DSW 321960 STLCOPCB4073610 I 1lj- HAIMDUrJG AP'D STORAGE As with all specialized industrial fluids, certain precautions are advisable when handling Pydraul fluids. No problems will arise when Pydraul fluids are used as recommended. Avoid repeated or continuous skin contact. Repeated or prolonged contact can lead to drying and skin "chapping." Where prolonged skin contact cannot be avoided, gloves should be worn. At room temperatures, there is no vapor inhala tion hazard from Pydraul; however, inhalation of vapors at high temperatures should be pre vented. In extensive animal experimentation, exposures to vapors for one hour showed local respiratory irritation, although no systemic effects were produced. Although eye irritation studies using Pydraul at full strength indicate Pydraul is a mild irri tant, there is no evidence to show Pydraul causes permanent damage to eye tissues. If Pydraul fluid is splashed or sprayed into the eyes, eyes J should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physicians have used 1% pontocaine solution, as well as the ophthalmic cortisone acetate solution. Pydraul hydraulic fluids can be stored at sub zero temperatures without fluid damage. Be fore using, simply allow the fluid to warm to room temperature. Drums stored outside should be sealed tightly and placed in a horizontal position to keep out moisture. / 41P< HANDLING DSW 321961 STLCOPCB4073611 iitfiwai STLCOPCB4073612