Document Mw4va1LZK3NZ41RxGkOeBNRM

AMERiCAN-STANDARD FR-A-7 flame retention oiJ heatLng_units___ or steam D uly, 1966 l T 12975 The new American-Standard FR-A-7 oil heating unit operates at greater efficiency and with higher out puts than comparably sized conventional boilers yet it costs no more to buy and install! The superior flame retention burner and improved interior design make it possible. The new FR-A-7 unit is available in 9 sizes for steam, forced circulation and gravity hot water. With an l = B = R approved output range of 1,160,000 to 3,000,000 Btuh, it's ideal for instal lation in most commercial and industrial buildings. For higher outputs - without paying higher costs make it the FR-A-7 on big oil jobs! Flame Retention Burner-uses a high speed fan in the housing and a special 12-blade spinner at the nozzle to produce an air-oil mixture so finely vaporized that every drop of fuel is burned. The flame is steady, quiet and concentrated into a well-defined pattern. More heat is gen erated: efficiency is improved: ratings are higher. On FR-A-7 units, the concentrated flame pattern of the burner and the fact that the combustion chamber is primarily for base insulation permits the combustion chamber to be smaller than in conventional boilers. This exposes more section area directly to the burner flame, resulting in greater efficiency and higher outputs. Lifetime cast iron sections tested at 2Vz times normal operating pressure Sturdy steel jackets, attractive gray finish, fully insulated Light-sensing primary controls External arrangement for domestic hot water 12976 FR-A-7 ratings unit numbers steam water gross l=B=R output (Btu/hr) net I=B-R ratings water t steam (Btu/hr) steam (sq. ft) water (sq. ft.) l=B=R burner e capacity (fph) l=B=R allowance for piping chimney size height (in.) (ft.) watei content ful) (gallons) FR-A-706-S0-B FR-A-707-SO-B FR-A-706-WO-B FR-A-707-W0-B 1,160.000 1,376.000 870,200 1,041,600 3626 4340 5801 10.55 1.333 16x16 30 167.3 6944 12.30 1.321 16x20 35 189.5 FR-A-708-SO-B FR-A-708-WO-B 1,580,000 1,211,700 5049 8078 14.15 1.304 16x20 35 211.6 FR-A-709-S0-B FR-A-709-W0-B 1,812.000 1,403,600 5848 9357 16.35 1.291 20x20 40 233.7 FR-A-710-SO-B FR-A-710-W0-B 2,020,000 1,568,300 6535 10455 18.15 1.288 20x20 45 255.9 FR-A-711-SO-B FR-A-711-WO-B 2,228,000 1,729,800 7208 11532 20.20 1.288 20x20 55 277.9 FR-A-712-SO-B FR-A-712-WO-B 2,440,000 1,894,400 7893 12629 21.95 1.288 20x24 60 302.5 FR-A-713-SO-B FR-A-713-WO-B 2,720,000 2,111,800 8799 14079 24.10 1.288 20x24 70 327.1 FR-A-714-SO-B FR-A-714-WO-B 3,000,000 2,329,200 9705 15528 26.30 1.288 24x24 80 351.7 FR-A-7 is tapped for external heater arrangement. For complete information on flame retention burners (nozzle sizes, etc.), refer to chart on back page. A. American-Standard should be consulted before selecting an FR oil heating unit for installations having unusual piping and pick up requirements. Note: FR-A-7 oil heating unit furnished with Pressuretrol for steam, Aquastat limit control for water. t American-Standard FR oil heating units are designed and built to comply with the American Society of Mechanical Engineers' Code and bear their approval symbol. Ratings have been approved by the Institute of Boiler and Radiator Manufacturers. control tappings location on unit A size ; (inches) i 4' -- steam water water heater--external type A -4" flow tapping 8 6 water heater--external type water heater--external type C 1 !- -- D 2Vi A.S.M.E. safety valve A.S.M.E. relief valve E 3 blow-off or pop safety valve water heater--external type F 3 water heater--external type water heater--external type G 3 water heater--external type water heater--external type H % steam pressure limit control water temperature limit control K 2>/2 internal low water cut-off -- L Vi water temperature control, water temperature control, domestic hot water domestic hot water rear view (showing control Tappings) M lVx nipple port inspection tapping nipple port inspection tapping * Not*: Special tapping. 6 tncnes Oelow water line, provided on front section for connecting tow water cut-off when required. 12977 3 . 1\ flame retention oil heating units sn oil heating units Tgs are intended solely to ping locations and general .Wai piping details snouid ce with standard engmeer- limensions (inches) 2L i'/* 49 9V, 56Vi 7 V. 64 t*. 71 Vi >'/ 79 )5'. 86Vi 94 IV. 101V2 >->/. 109 number and size of tappings (inches) FR-A-708 through FR-A-714 only. legend flow (3)-4 (3)-4 (3)-4 (4)-4 (4)-4 (4J-4 (5)-4 (5)-4 (S)-4 return <21-6 (2)-6 (2)-6 (2)-6 (2)-6 (2)-6 (2)-6 (2)-6 (2)-6 assemblage of sections FX, C, CX, C, RC, BX FX, C, C, CX, C, RC, BX FX, FC, C. CX, C, RC, RC, BX FX, FC, CX. C, C, CX, RC, RC, BX FX, FC, CX. C, C, CX, C, RC, RC, BX FX--front connecting section C--center section CX--center connecting section FC--front center section RC--rear center section RCX--rear center connecting section BX--back connecting section FX, FC, FC, CX, C, C, CX, RC. RC, RC, BX _FX, FC, FC, CX, C, C, CX, C. RC, RCX, RC, B FX, FC, FC, CX, C, C. CX, C. C, RCX, RC, RC FX, FC, FC, CX, C. C. CX, C, C, CX, RC, RC, iber dimensions (inches) A r diameter (inches) 6 6 Vi 7 6 Vi 3 6 Vi 9 7 V. 0 7V. 1 7V. 2 7V. 3 7V. i 8V. inside chamber length (inches) 35 42V. 38 41 44 47 50 53 56 hrough FR-A-710 FR-A-706 and FR-A-707 FR-A-711 through FR-A-714 Jer / to supply er / 'o supply AMERICAN STANDARD PlUMBINC & HHATJNC DIVISION \ AMERICAN STANDARD NO Hf MINO 12978 flame retention oil heating units flame retention burner specifications (2*stage fuel unit) unit number burner number l=B=R capacity (fpti) number required FR-A-706 FR-A-707 FR-A-708 96A-M-7543-B 96A-M-7543-B 96A-T-7935-K* 10.55 12.30 14.15 two two three FR-A-709 FR-A-710 FR-A-711 FR-A-712 96A-T-7937-K* 970-8111-B 970-8111-B 97A Hi-Lo-7673-EA 16.35 18.15 20.20 21.95 three two two three FR-A-713 97A Hi-Lo-7673-EA 24.10 three FR-A-714 98A Hi-Lo-7773-Ea 26.30 four nozzle data gph each way angle ' --* t o N fO ' 88 (11-5.00 (D-5.50 (2)-6.00 (21-6.50 (D-3.00 (2)-9.00 (2)-10.00 (2>-6.00 (D-10.00 (21-6.00 (D-12.00 (21-9.00 (21-4.00 cOOocO0o 80 80 80 90 90 90 90 70 70 80 80 80 80 type solid solid solid solid solid solid solid solid solid solid solid solid solid solid solid mount pedestal pedestal pedestal pedestal pedestal pedestal pedestal pedestal pedestal Electronic flame safeguard control: RA890E Protectorelay and Q270Abase, C7013A photocell. Provides 15-second trial-for-ignition and 15-second flame-failure-shutdown. Available with optional controls to meet Factory Mutual Approval: RA890E Protectorelay, W415A panel (includes Q270A base and RA88F switching relay), C7013A photocell. Provides 15-second trial-for-ignition and 2- to 4-second flame-failure-shutdown. *R4150A Electronic flame safeguard programming panel, C7013A photocell. Provides 10-second trial-for-ignition and 2- to 4-second flame-failure-shutdown. Other listed burners are furnished with factory-installed cad cell, bracket and leads. R8184B light-sensing constant ignition primary control in accord with UL requirements as follows: primary control no. burner nozzle capacity flame-failure shutdown R8184B1204 3 to 7 gph 30 seconds R8184B1196 7 to 20 gph 15 seconds Oil burners regularly furnished with light-sensing primary are avail able with electronic flame safeguard controls to meet UL and Factory Mutual Approval. See current price book for description. APPROVAL: American-Standard flame retention oil burners (115 and 230 volt/60 cycle) are listed with Underwriters' Laboratories, Inc. for No. 1 and No. 2 grades of fuel oil, whether obtained by distillation or catalytic cracking process. They are approved by the New York City Board of Standards and Appeals, the State Fire Marshal of the Commonwealth of Massachusetts, and the Department of State Police, State of Connecticut. sample specification for FR-A-7 oil heating unit Contractor shall furnish and install, as indicated on plans, FR-A-7........ oil heating unit(s) having a firing rate of.......... gph and an l = B = R gross output of..........Btuh. Boiler(s) shall be constructed of cast iron in accordance with A.S.M.E. requirements for low pressure heating boilers and bear the A.S.M.E. symbol. Each section shall be factory tested at 2Vi times maximum working pressure of 50 lbs. for water. Boiler(s) shall have l=B=R ratings. Contractor shall furnish where required (on 8 through 14 section sizes) 8-inch channel steel pedestal base under regular 12-inch cast iron base as manufactured and recommended by boiler manufacturer. Boiler sections shall be so constructed that the water line for steam boilers shall be above the bottom of top nipple ports to insure proper water circulation be tween sections. Rear section shall have external water heater tappings as provided by the manufacturer. Boiler flue passages shall be horizontal, finned type, baffled as recommended by manufacturer, with flue travel along both side passages from rear to front and back through center passages to rear and smoke collar connection. Water or steam trim as required. Oil burners shall include controls as herein described. (Note-. Include description of controls as required and other burner features as desired.) Nc rit AMERICAN STANDARD PLUMBING & HEATING DIVISION 411 WIST JOTH STREET \E'.V IORK \Y 1001R 12979 Lit ho in U S A