Document MobJqXeaLbXO5d772B1nm4oNa
operator of such plant that the alternative program will, provide plant personnel and Agency -personnel.with an ability ego1valent to the monitoring, recordkeeping or reporting requirements of this fart to Identify and repair leaking components. ' The owner 'or operator utilizing an alternative monitoring program shall submit to the Agency an alternative monitoring program plan consistent with the provisions of Section 21S.4H.
(Source: Added at 11 til. keg. 20829. effective Oeceofccr. M. 1987>
Section 215.417 Open-Ended Valves
a) Each open-ended valve shall be equipped with a cap. blind flange', plug, or a second valve.
. except during operations- requiring fluid flow, through the'open-ended valve. '
b) Each open-ended valve equipped with a second " .valve shall?be.operated'ln a maimer such that the valve on the process fluid end is closed
before, the second valve Is closed.
c) Opep-ended)valves which serve as a sampling. ,
,connection shall be equipped with'a closed
-purge system or closed vent system such that:'
'. > '.
. 1) Purged process fluid shall be returned to . the process line-with-zero VOM emissions to atmosphere, or '*-*"**.* ' * ^
2} Purged process fluid shall be collected -and-recycled to the process Vine with zero volatlie organic material emissions .to atmosphere.
(Source: Added at 11 111. Reg. 20829. effective Oecember 14. 1987)
Section 21S.-418 Compliance Date
The owner or operator of a synthetic organic Chemical or polymer manufacturing plant subject to Sections 21S.410 through 2IS.418 shall comply with the standards and limitations of those Sections.,no later than December 11. 1987.
(Source: . Added at ll 111. Reg. 20829. effective December 14. 1987)
; .
SU8PART R: PETROtEUH REFtNING AND REtATEO INDUSTRIES: ASPHALT MATERIALS
Section. 2-15.441. Petroleum Refinery Waste Gas Disposal
a) Except as provided In subsection (b) or (c).
no person shall cause or`allow the discharge
of organic materials In excess of 100 ppm
equivalent methane (molecular weight 16.0)
Into the atmosphere from:
-
)) Any catalyst regenerator of a petroleum cracking system: or
2)- Any petroTeum fluid cok'er; or
1) Any other, waste 'gas stream from any petroleum or petrochemical manufacturing process.
b) Exception. Existing sources subject to subsection (a)(1) may. alternatively, at their, election, comply with the organic material emission 11ml tat Tons Imposed by Section 21S.101 or 21S.102: provided, however, that there shall be no Increase In emissions man such sources above the level of-emissions In existence on May 1. 1979.
c) New'Sources.. . Sources subject to subsection (a)(1). construction of Mitch -commenced on or lifter January :1. 1977. may;, at their election.-.comply with the following emission limitations:
1) A-mo*1m*-of->-etght''pounds per hour of - organic material; or
2) Emission of organic material in excess of the Tflaframm orsubsectTwrfcKlT ir allowable If such emissions are controlled by air pollution control
. . methods, or equipment approved by the Agency capable of reducing by 8S percent or more.the uncontrolled organic material that would otherwise be emitted to the atmosphere,
(Source:' Amended at rmv Reg.' 1T*V effective
July 28. 1979)
Section 2)5.442 Vacuum Producing Systems
No owner or operator of ~a petroleum ref inery shall 'cause dr allow the operation of any vacuus producing system unless the condensers, hot wells and accumulators of. any such system are equipped with vapor loss control'dqulpmenr Including, but not limited to. piping; valves, flame arrestors and.hot well,-covers to vent any -volat I le oryanfirmstertaT"wtttrr vapor pressureof 10.14 kPa (l.S psta) or greater at 294.1* (70*F) to a.heater, fire box. flare, refinery fuel gas system or other equipment or system of" equal emission control as approved by the Agency. This Section shall not apply to vacuum producing-systems on-lube-unlts-.
(Source: Amended at 12 111. Reg^ 81S. effective December 24. 1987)
Section 21S.44] Wastewater (011/witer) Separator
No owner or. operator .of:.*, petroleum cetlnecy..... shall operate any wastewater (oil/water) separator at a petroleum refinery unless the separator Is equipped.with air pollution control equipment, capable of reducing,by.8S percent or more the uncontrolled organic material emitted to the atmosphere. If no odor nuisance exists, the limitation of this Section shall not apply If the vapor pressure of .the-organic material *s below ia-14.kR*.t(LJ..psA*J.*L.T05-r.f L?0F at all times.
ill -