Document Moa1329dyMJjwXzQXX3ZeGMz
Introducing Therminol 66
Therminol 66 is a heat transfer fluid for use in liquid phase between 0-650F without system pressurization. The low pour point of this product permits start up at fluid temperatures as low as 0F.
Td minimize fluid oxidation, systems with Thermi nol 66 should be blanketed with an inert atmos phere. A system relief valve should also be provided. Therminol 66 is ideally suited to replace organic fluids that have lower boiling points and must operate under system pressure at 650F.
Therminol 66 can support combustion and should
not be confused with Monsanto's Therminol FR
fire-resistant fluids.
.
TYPICAL PROPERTIES OF THERMINOL 66
Composition Appearance Color Odor Pour Point
Flash Point
Flame Point
Autoignition Temp. Coefficient of Expansion Boiling Range
Modified terphenyls
Oily liquid
Practically colorless
Faint, characteristic
-26------ 28C. -15------18F.
168 - 180C. 334 -- 356F. .
190 -- 202C. 374 -- 392F.
364C. 705F.
0.000741 cc/cc/C.
340 - 396C 644 - 745F
STLCOPCB4066600