Pydraul(R) 135 . Fire-Resistant Hydraulic Fluid Pydraul 135 Fire-Resistant Hydraulic Fluid ... a low viscosity synthetic that gives you the performance of premium grade petroleum oils plus safety - at the price of water/ glycols.
o/ff -4
)ia\wicv-
0619701
TOWOLDMONOQ39490
Table of Contents
Introduction.............................
Properties of Pydraul 13S
Chei:, ic.nl............................. Inspection............................. Corrosion and Stability five Resistance . . . . Performance ........................
Mixing Compatibility. . .
Change-over Procedures.. .
Handling and Storage. . .
Obi**702
I
TOWOLDMONOQ39491
Introducing Pydraul 135 hydraulic fluid ... Pydr:.ul(l R'1) 155 is one of Monsanto's growing line of internationally
accented, fire-resistant hydraulic fluids and lubricants.
Pydraul 135 is a sister product of recently introduced Pydraul 312. doth are forerunner of a new chemical concept in hydraulic fluids ... a unique marriages of synthetic fluids with specially chosen petroleum fractions. The result is a fire-resistant hydraulic fluid that matches or excells the properties of existing hydraulic fluids -- including synthetics, premium grade petroleum oils and water-containing fluids -- but sells in the same price range as water/glycol fluids and offers up to 402 savings over other water-free, fire-resistant hydraulic fluids!
Pydraul hydraulic fluids first began working to protect hydraulic operations from fire in 1951. Today, the seven Pydraul fluids have performed millions of machine hours of service without con tributing, to a single fire ... not even when sprayed from rup tured high-pressure hydraulic lines onto white-hot metal. In addition to fire-resistance, the Pydraul fluids have always offered
f
/
... lubrication as good as premium grade oils
... freedom from corrosive action and.foam
... ease of maintenance
' ... and permanence -- they don't "wear out"
*
TOWOLDMON0039492
y Chemically Speaking ... Pydraul 115 fluid is a permanent solution of carefully selected petroleum fractions in a synthetic base of halogenated hydro carbons and phosphate esters. Chemically similar to Pydraul 312, this new fluid offers fire-resistance, lasting chemical stability, no oxidation or corrosion in normal service, and minimum maintenance for your low viscosity machines.
0619704
TOWOLDMONOQ39493
Inspection Properties ...
Viscosity, SSU 9 40F
Viscosity, SSU 100F
Viscosity, SSU 9 210F
Viscosity Index
Pour Point, F
Density 2S/25
Grams/cc pounds/gal
-
ASTM D-892 Foam Test
Sequence I
Sequence II
Sequence III
1600 140.9
40.9 f-49 -10
\.n
9.92
pass pass pass
The viscosity and viscosity index of Pydraul 13S are very similar to those of a high quality R50 (rust and oxidation inhibited) type petroleum hydraulic oil as the comparative viscosity curves indicate,
0619705
TOWOLDMONOQ39494
TEMPERATURE. DEGREESFAHRENHEJT'
mm nummmmmm
' ttOVOM'S
VISCOSITY/SAYBOLT UNIVERSAL' SECONDS. VISCOSITY. SAYBOLT. UNIVERSAL SECONDS
a a n is n id in ii9 i m is n in in in to to zn to w w.mjJiiiiH'M 2# w m w w s
" TEMPERATURE. DEGREES FAHRENHEIT `
CCTY^'CHT. '* aufricau society for testing a*<o materials
t1 MACE ST.. PWlUMJei^HTA J. *A_
7
Corrosion Stability ... The corrosion and oxidation stability properties o Pydraul 13S are equal to those of the best petroleum hydraulic fluids. Pydraul ^ 13S will not rust or corrode any metal in a hydraulic system even 1 when over-heated to 250F.
In the ASTM D-66S Rust Test Pydraul 135 showed no rust at iall, and in use Pydraul 135 does not lose its anti-rust properties.
Good hydrolytic stability is a basic characteristic of Pydraul 13S. If water somehow enters your hydraulic system, Pydraul 135 won't. hydrolyze to foam acidic or corrosive products.
Beverage Bottle Test (Pydraui 135 plus water aged 8 200F for
48 hours with a copper strip through both phases).
Neutral No. Change, mg KOH/mg
+0.^2
Viscosity change, i 6 100F
+1.0
Insolubles
\ t 6 210E
+0.4 none
Copper strip
no corrosion
\
0619707
I
TOWOLDMON0039496
Fire Resistance ...
Pydraul 135 is an industrial fire-resistant hydraulic fluid listed by Underwriters' Laboratory.
Miscellaneous Fire-Resistance Tests
ASTM D-2155, Auto. Ing. Temp F
760
High Pressure Spray Test (AMS-31S0C) Test fluid sprayed at 1000 psi through orifice, passing through flame of oxyacetylene torch, 6000F
Intermittent flashing but self-extinguishing,
Low Pressure Spray Test (AMS-3150C).
Slight increase in flame
Test fluid sprayed at low pressure over ' Intensity,
ignited, oil-soaked rags to determine
degree of increase in flame intensity,
Hot manifold test (AMS 3150-C) Test fluid dripped on tube at 1300F.
of trz/'F
Intermittent flashing but self-extinguishing.
Does not flash
.
Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200F to test for spontaneous ignition.
Does not ignite spontaneously, Flashes intermittently with ignition source.
i
|j
U.S. Bureau of Mines Schedule 30 Fire Tests*:
Pipe Cleaner Test, Number of Cycles: Fresh Fluid
28
Aged 4 hours 6 150F
'24
Temperature/Pressure Spray Ignition Test:
Propane Torch
Electric Arc Burning Kerosene-Soaked Cotton
pass pass pass
Ask to see the color motion picture, "Before Hydraulic Fires Start.
0619708
^Although Pydraul 135 fluid meets U.S. Bureau of Mines fire-test
requirements, it is not approved since required field tests in
mining machinery have not been completed.
"
TOWOLDMONOQ39497
?
Performance Properties ... Pydraul 13S has good viscosity and viscosity-temperature (V.I.) properties. These properties are permanent. Pydraul 135 will V not shear mechanically to degrade viscosity. The following chart shows viscosity of Pydraul 135 before a JiS
Vickers Hydraulic Pump Test ... and practically the same viscosity
after the test.
Vickers Hydraulic Vane Pump Test ^ .vMiA )
(V-105E pump, 1000 hours, 140F, 1000 psi)
I Viscosity change 6 100F 210eF
+11 +5
/H4 Weight oss of pump parts, ^m.
bushings, 2015 bushings, 2016 Ring Vane
21 11 22
2
.
619709 I
TOWOLDMONOQ39498
''*V ' .TEMPERATURE, OEGREESFAHREKHETT' _ / :
9 hu urn in it* ex v$ m m m
AltnCAM'STJUtOUtf'
VISCOSITY, SAY0OLT, UNIVERSAL SECONDS
pfliHreo imj. i a.
SI U 79 II U II III AS 19 Ut D
TEMPERATURE, DEGREES FAHRENHEfT.
^6LDMON0039499
In the severe Vickers Hydraulic Pump Test (V105C pump), Pydraul 13S lubricates as well or better than high-quality R$0 petroleum oils.
//
TOWOLDMON0039500
iJL'
'A 1
Four Ball Wear Test (620 rpm, 1 hour,
Steel on steel, mm scar diameter
4 kg load
0.1S
10 kg load
0.24
40 kg load
0.43
Steel on bronze
10 kg load
0.4 S
Timken Test
Timken OK load, lbs.
45
Pydraul 135 lubricates under extreme pressure as well as highquality industrial gear lubricants, Field Tests In addition to the laboratory tests, Pydraul 135 has been thoroughly evaluated for use in ASKANIA type regulators. Gene', .. approvals for its use have been given by major equipment manufacturers. Pydraul 135 will give years of trouble-free pump service ... the same long pump life afforddd by high-quality RfiO type petroluem hydraulic oils.
And Pydraul 135 doesn't wear out. Except for normal "make-up",
... you don't add water
... you don't have "drain and change" periods
... you don't have to check it daily
... or perform most of the other-time-consuming maintenance
necessary with water-containing fluids.
0619712
TOWOLDMONOQ39501
Mix /Compatibility ...
Pyd-. 'il 13S solubility with other hydraulic fluids
Other Pydraul Fluids
.
CA-2J0, F-9, ISO, 62S, 5312)
Pydraul 13S Soluble in all proportions
Other commerical Phosphate Esters (Houfjhto-Safe 1130, Ccllulube 220, etc.)
Watcr/Glycol Phosphate Esters
Potroloum oils
55 phosphate ester is soluble in Pydraul 135 at room tcrapcrature ; 105 is insoluble at room temperature
Insoluble in wator/filycol fluids and vice versa
Soluble'in all proportions, but oil contamination can reduce Pydraul 135 fire-resistant qualities.
06X9713
\
TOWOLDMONOQ39502
//
Change-Over Procedures Converting to Pydraul 135 hydraulic fluid is easy. Virtually ever type of equipment that uses fire-resistant hydraulic fluid has been converted to Pydraul fluids. Equipment manu facturers are, therefore, experienced in Pydraul fluid conversions and should be consulted.
If changing seals is necessary, equipment manufacturers can tell
you '..hat seals to change, and most even carry-a supply of correct seals. Laboratory tests show that Viton^ A.is the preferred
elastomer for compatible seals. For moderate temperatures,
(bel ow,140) Butyl seals, hose, etc. appoar acceptable.
To 1 'lace other Pydraul fluids with Pydraul 135, where com
patible seals are in the system, it is only necessary to add
.
Pydraul 135 as make-up fluid. It is not necessary to drain
or clean. When you convert from petroleum oils,other synthetic
fluids, watcr/glycol fluids, or water-in-oil emulsions, we
recommend tiie following steps. These steps conform to National
Fluid Power Association Standards.
Your Monsanto representative will assist you any way he can,
or you can telephone our technical specialists in St. Louis
,directly.
.....
(1),Trademark of E.I. duPont de Nemours 5 Co., Inc.
i
I
'
'
0619714
TOWOLDMONOQ39503
Char, j.ng from Petroleum Oil
1. Completely drain and clean the system. Small amounts
of oil will not interfere with the performance of Pydroul
I3S, but resistance to firo is reduced by tho amount of oil left in the system.
2. : rain and blow out pipelines. Manually clean valves
;d reservoirs.
3. pen or remove and drain valves. Replace gaskets, packings,
and seals with those compatible with Pydraul 13S. It is
particularly impor*tant to change-dynamic seals. Static seals do not necessarily have to be .Changed if there is
no objection to replacing them each time hydraulic components
uro serviced.
4. Remove pumps, accumulators, and cylinders, if necessary,
..
for draining. Replace.packings, seals, gaskets, and bladders
with those compatible with Pydraul 135.
5. Cneck component functions before the system is closed and
fluid is added.
6. If your system cannot be completely drained, you may have
to flush it with a small amount of Pydraul 135
'
Changing from Water/Glycol or Water-in-Oil Emulsion 1. Drain and clean system thoroughly. Remove all traces of water.
Empty all lines and low points or dead pockets in components. 2. Clean with steam or warm water. Follow by blowing with
dry air.
06197X5
TOWOLDMONOQ39504
3 :.':icck sealing materials, hoses, and accumulator bags. W: eplace if necessary with compatible materials.
4. ' . astall a minimum charge of Pydraul 13S and operate the . -ystem from 16 to 24 hours. During this period, inspect !no reservoir. If water or other contaminants float to tiic top, skim them off.
5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points Or parts which do not^drain back to'the reservoir. If water is apparent in fluid clinging to walls, wipe, down all accessible parts.
Changing from Phosphate Esters (Other than Pydraul) ), Drain the system completely. 2\ Cleaning is unnecessary. 3. Generally, seal changes are unnecessary.
,
'
Handling arid Storage As with all specialized industrial fluids, certain precautions are advisable when handling Pydraul 13S. No problems will arise when Pydraul 13S^used as recommended.
Avoid repeated or continuous skin contact. Repeated or prolonged contact can lead to drying and skin "chapping". Where prolonged skin contact cannot be avoided, gloves should be worn.
0619716
I
TOWOLDMONOQ39505
//
, '.i
At room temperature there is no significant vapor inhalation hazard from Pydraul 135; however, inhalation of vapors pro duced when the fluid is at high temperatures should be prevented, dinglo 6-hour exposures to an atmosphere saturated with vapors at ambient temperatures produced only mild discomfort in ex perimental animals and they survived the 10-day subsoquont ob servation period without ill effect. Although eye irritation studies using Pydraul 135 at full
strength indicate Pydra< ul 135 is a mild irritant, there is no
evidence to show Pydraul 135 causes permanent damage to eye tissue. If Pydraul 135 is splashed or sprayed into the eyes, eyes should be thoroughly flushed with water and the workman referred to a physician. To relieve irritation, physicians have used 14 tetracaine solutions, as well as ophthalmic cortisone acetate solution. Pydraul 135 hydraulic fluid can be stored at subzero temperatures without fluid damage. Before using, simply allow the fluid to warm to 20 -- 30F. Drums stored outside should be sealed tight 1y and placed in a horizontal position to keep out moisture.
ob\W
TOWOLDMONOQ39506