Document MdLbez3GoKxq11JmBDRqz1aL

A C4efntca$- INC. ESCAMBIA PLANT INTEROFFICE MEMORANDUM To: Distribution From: W. J. Stueben DaTe: Copies: 16 July 1979 Re: Blood Test For Vinyl Chloride Exposure Dr. Beidleman has informed us that the SMA 12 blood test called for in the emergency procedures manual is no longer adequate. The blood test to be given is a Liver Profile with additional tests for SPGT, GGPT and LAP. Please review this with your personnel immediately. The Emergency Procedures Manual will be changed accordingly. WJSrjsf Distribution: R. E. Gilbert L. W. Allen J. M. Diamond R. L. Duggan X* E. Greene T. J. Regan Good/Lay/Middlebrooks C. W. Brooks B. M. Mize V, o W. J. Stueben wv.ii tfi* . GR-- K AP00042158 To: From: Re: J. G, Tolar OSiik VCM Personnel Monitoring Requirement Date: Copies: 19 September 1979 L- \V. Allen J. M. Diamond K. J. Femrite L>. S. Forester Please clarify if there is an OSHA requirement for 15 minute ceiling exposures for VCM personnel monitoring. If there is, does it apply to mechanics as well as operators? ! JGT:ms V!C . j y i 2,rv .4-, r'" J. G. Tolar > .v t 4#> % v. & AP00042159 A a*uC $iefMcaj& ISCAMtt A PLANT INTEROFFICE MEMORANDUM To; R. L. Duggan ^ 1 ) |0 From: Re: L. W. Allen /\ J w\ Vinyl Chloride Area M Monitoring System Copies: 1-1 July 1979 R. E. Gilbert T. J. Regan W. J. Stueben A. E. Greene J. Benson T. Nichols J. M- Diamond Program modifications are being made to the area monitoring system to allow the horns to be activated at 5 ppm and above. Audio alarms, in addition to colored lights, will provide the necessary warning to personnel as to what action must be taken to eliminate the chance of vinyl chloride exposure. LWA:bg c* *0 7 L* w. Allen AP00042160 A To: From: Re: a*td {%&mtca$- ESCAMBIA PLANT INTEROFFICE MEMORANDUM Date: 13 June 1979 Copies: T. Regan W. Stueben E. Ray K. Femrite L. Allen R. Gilbert A. Greene ^ We have received two fifteen minute personnel monitoring sample analyses with readings of 21.07 PPM and 1.01 PPM. Both of the above samples were taken'while Donald Gunter and Roy Curry were in the PVC CRT room. We feel these analyses were not valid and more attention should be put on the method of analyzing our monitoring samples. JMD:si pLh 0 John Diasmond AP00042161 ESCAMBIA PLANT INTEROFFICE MEMORANDUM To: From: Re: J. M. Diamond G* Tolar VCM Monitoring Unusual Results 5 June 1979 Dote; 20 June 1979 Copies: L. Allen R. Duggan L. Forester A. Greene K. Femrite R. Gilbert E. Ray T. Regan Your memo (attached) blames unusually high results of VCM monitoring of two fifteen minute personnel monitoring samples in the CRT room on analytical problems. It is understandable that analysis would be suspected under the cir cumstances. Fortunately, the two samples had been saved, therefore, the analysis was repeated and the same results were obtained. In addition, the samples were also analyzed on different GC's and GC columns, and similar results were obtained. All data indicates there is not an analytical problem related to these high values. I believe that either: (a) The sample tubes, not necessarily the personnel, were exposed to the VCM level as indicated. This was during a period that a lot of VCM samples were being taken and analyzed. Exposure may have come from an area other than the CRT room, in the QA lab, for example. The possiblity of a high level in the CRT room during this period, due to all of the work with VCM is not as remote as one might think, (b) Sample tubes could have been switched or samples mixed up. (c) It is conceivable, but unlikely, the personnel were exposed to another chemical which would have the same GC retention time as VCM. We are working on this possibility now. In the future, if a bad analysis is suspected, K. J. Femrite or I should be notified immediately so that it can be resolved as soon as possible without involving others until facts are known. JGT:m8 J. G. Tolar AP00042162 CP'fot 'T^Ot/acU- atu/ &cs/itca& CSCAMSIA PLANT INTEROFFICE MEMORANDUM To-. R. Duggan From: J Diamond Re: VCM Monitoring Date: 13 June 1979 Copies: T. Regan W. Stueben E. Hay K. Femrite ^ L. Allen R. Gilbert , A. Greene We have received two fifteen minute personnel monitoring sample analyses with readings of 21 .07 PPM and 1.01 PPM. Both of the above samples- were taken while Donald Gunter and Roy Curry were In the PVC CRT room. We feel these analyses were not valid and more attention should be put on the method of analyzing our monitoring samples. JMD:sl Id- jf John Diamond AP00042163 C7^/^itt and CA&mica& A ESCAMBIA PLANT IMC. INTEROFFICE MEMORANDUM To: From: Re: J. Diamond Dote: 28 June 1979 K. Femrite VCM Monitoring - Unusual Results of 5 June 1979 Reference: A - J. Diamond to R. Duggan Copies: L. Allen R. Duggan L. Forester A. Greene R. Gilbert E. Ray T. Regan Due to your concern in reference A about two ceiling exposure determinations taken in the PVC CRT room the sample which showed 21.1 ppm VCM was reanalyzed to confirm the original level of VCM and to determine if the GC peak believed to be VCM was indeed VCM. Reanalysis at standard conditions showed 16. 6 ppm VCM which is still well above the ceiling exposure limit of 5 ppm Lower levels of VCM were not unexpected as the sample vial, septum had been punctured several times which leads to a loss of VCM in the desorbing solution. The sample was then evaluated on two different columns to determine if two or more chemicals may comprise the GC peak, believed to be VCM. Both columns failed to separate the GC peak into any com ponent peaks with the retention time of the peak matching that of VCM in standards. From this data I can only conclude that the original analysis of 21.1 ppm was valid and the GC peak was indeed VCM. KF:ms K. Femrite AP00042164 A and C6&trucai- CSCAMfllA PLANT INTEROFFICE MEMORANDUM To*. Jim Tolar From: Larry Allen Re: Personnel Monitoring Program for Vinyl Chloride Dote: 28 November 1979 Copies: A. E. Greene T. J. Regan R. E. Gilbert W. J. Stueben R. L. Duggan E. A. Ray R. A. Scott J. M. Diamond In light of the recent testing problems found with the personnel monitoring program, the writer surveyed several companies to find out what methods they are using. Borden Chemical They are using the Bendix Flasher tube with the Bendix pump. These tubes are carbon and can be regenerated. Their life is approximately one year. Conoco Chemicals Conoco uses badges manufactured by Risner Environmental Laboratory. They are also evaluating 3M and DuPont badges. Their major concern with 3M and DuPont badges is their capacity. This problem can, however, be solved by adding additional wafers to the badge. In the beginning they used the carbon cube and pump. They were not able to get satis factory analytical results. A switch was then made to bags and pumps (Method 106}. They feel their present badge system is the best and most reliable to date. Diamond Shamrock Diamond presently uses Bendix Flasher tubes and pumps. They are currently evaluating 3M badges. Georgia Pacific They have been using 3M badges for about ten months. The present badge program is much more reliable and cheaper than their previous carbon tube and pump program. B . F . Goodrich B.F.G. uses the Flasher tube and pump made by Bendix. They evaluated the 3M Badges and were not able to get satisfactory correlittfiSNAtti the ftGV 3 0 1979 A. H. OREM AP00042165 Jim Tolar Personnel Monitoring Program for Vinyl Chloride B. F. Goodrich (continued) 28 November 1979 Page Z carbon tube. Their main efforts are directed towards eliminating the program. They plan to correlate the area monitoring data and specific operating jobs to show personnel exposure. Their people feel OSHA wiLL allow this substitution. Stauffer Chemical Company Stauffer uses the 3M Badge for their personnel monitoring program. They feel the program is more reliable than the pump and bag method. In conclusion, half the companies contacted use badges and the other half use Bendix Flasher Tubes and pumps. A major point of interest is that the biggest PVC producer is channeling their efforts in the direction of eliminating the present type of personnel monitoring equipment used by all companies. LWA: bg Larry W. Allen AP00042166