Document MVBN49xae30G3pybq5pqQZ3a
458
CHAPTER 19
1955 Guide
Table 1. First Story Warm Air Ducts*
Warm Air Combination
No.,
Throat Sue
Leader Pipe
Diameter, Inches
Pipe Area Sq In
Register Size, Inches
__ Baseboard
Size
Extension
Floor
i
6% x 10
8
2
6%xl2
9
3
7% x 12
10
4
9M x 13
12
3db 8% x 12 10
4db 10% x 12 . 12
50 64 78 113
78 113
10 x 8 12 x 8 12 x 9 13 x 11 . 2(12 x 8) 2(12 x 9)
2M . 2)4 3)4 5)4 2)4
3%
8 x 10 9 x 12 10 x 12 12x14
* When the calculations indicate a requirement for a given room greater than Combination No. 4, two or more smaller units totalling the required capadty are reoommended.
- b Double headers are permissible only where.full throat'areas are obtainable and room privacy is not
essential. .Use combination number representing total load. Combinations 3d and 4d have same capacities in Table 6 as combination 3 and 4 respectively.
Table 2. Second Story Warm Air Ducts--Single Wall Stacks and Fittings
Combi-,
nation. No.
. Stack, Sue, Inches
Leader Pipe Di AMETER,
Inches
Pipe
Area Sq In
Register Size, Inches
Baseboard
Size
Extension
' Floor
Sidewall
u 10 x 3)4 12 12 x 3)4
14 14x3)4 15 12 x 5)4 16 14 x 5)4 12db 12 x 3)4 14db 14x3)4
8 9 10 12 12
9 10
50 10 x 8 2)4 8 x 10 10 x 8
64 12 x 8 .2)4 9 x 12 12x8
78
13 x 11
2)4
12x8
113 12 x 9 3)4
113
13 x 11
5)4
64 2(12 x 8)
2)4
2(12 x 8)
78 2(12 x 8)
2)4
2(12 x 8)
* Recommended 6tack sixes. Tables may also be applied to 3 in. and 3 1/2 in; stack depths, b Combinations 12-d and 14-d have same capacities in Table 7 as combinations 12 and 14 respectively.
Table 3. Second Story Warm Air Ducts--Double Wall Stacks and Fittings
Combi
nation
No.
Leader Pipe Di ameter, .
. In. .
Pipe Area Sq In.
Stack Size, In.
Internal
External
21 8 50 2)4* x 10 3)4* X 10% 22 8 50 3 x 10 3% x 10% 23 9 64 2)4* x 12 3)4* x 12% 24 9 64 3 x 12 3% x 12%
? Commercial sizes vary 1/8 in. from values shown.
Register Sue, In.
Floor
8 x 10 8 x 10 9 x 12 9 x 12
Baseboard
Size
10 x 8 10 x 8 12 x 8 12 x 8
Ex tension
2)4 2)4 2)4 2)4
Sidewall
10x8 10 x 8 12x8 12 x 8_
all correlated. Similarly in the case of return ducts, the selection specifies a complete unit consisting of return grille, return duct, and shoe connection.
Recommended Standard Sizes
For the purpose of simplification and standardization, selected combina tions of commercial sizes of warm air pipes, return air pipes, ducts, grm' fittings, and registers are .designated as Combination Numbers. numbers assigned: and'the! combinations selected as standard are listed w :the following Tables 1 to 4 inclusive.3
The selected types of fittings are shown in Fig. 2, and their resistances ex-
Gravity Warm Air Systems
459
Table 4. Return Air Ducts
Combi nation
No.
Doer Dia. In.
Duct
Area So. In.
When Joist Space
Is Used*
No. of Min,b Joists . Depth Lined In.
Metal-Grille Sizes Choose.One
ABC
When
Base board Intake
Area at . Shoe Con
Duct Is Used
fob First
nection,
Story
Sq. In. Choose One
31 10 78
17
Sx 14 10 x 12
-
32 12 113
.1 9
6x30 8x24 12 x 14 14 x 10
' or 2
5
4-In. Ext.
33 14 154
1 12
8x30 10 x 24 14 x 16
or 2
6-
. 170
34 16 201
1 .18 :. 10x30 12 x 24
or 2
8
220
35 18 254
2 10
12 x 30 14 x 24
30 x 10 4-In. Ext.
280
36 20 314
2 12.5 14 x 30 18 x 24
340
37 22 380
2 15.0 18x30
420
38 24 452
2 18.0 20x30
500
14 x 6 12 x 8
22 x 6 16 x 8
28 x 6 22 x 8
28 x 8 22 x 10
36 x 8 28 x 10
36 x 10 30 x 12
42 x 10 36 x 12
42 x 12 36 x 14
`Based on 14 in. space between joists.
" Use full depth of joist except when joist depth is less than minimum depth required, when pan mutt be uted.
Fig. 2. Typical Warm Air Boots