Document MVBN49xae30G3pybq5pqQZ3a

458 CHAPTER 19 1955 Guide Table 1. First Story Warm Air Ducts* Warm Air Combination No., Throat Sue Leader Pipe Diameter, Inches Pipe Area Sq In Register Size, Inches __ Baseboard Size Extension Floor i 6% x 10 8 2 6%xl2 9 3 7% x 12 10 4 9M x 13 12 3db 8% x 12 10 4db 10% x 12 . 12 50 64 78 113 78 113 10 x 8 12 x 8 12 x 9 13 x 11 . 2(12 x 8) 2(12 x 9) 2M . 2)4 3)4 5)4 2)4 3% 8 x 10 9 x 12 10 x 12 12x14 * When the calculations indicate a requirement for a given room greater than Combination No. 4, two or more smaller units totalling the required capadty are reoommended. - b Double headers are permissible only where.full throat'areas are obtainable and room privacy is not essential. .Use combination number representing total load. Combinations 3d and 4d have same capacities in Table 6 as combination 3 and 4 respectively. Table 2. Second Story Warm Air Ducts--Single Wall Stacks and Fittings Combi-, nation. No. . Stack, Sue, Inches Leader Pipe Di AMETER, Inches Pipe Area Sq In Register Size, Inches Baseboard Size Extension ' Floor Sidewall u 10 x 3)4 12 12 x 3)4 14 14x3)4 15 12 x 5)4 16 14 x 5)4 12db 12 x 3)4 14db 14x3)4 8 9 10 12 12 9 10 50 10 x 8 2)4 8 x 10 10 x 8 64 12 x 8 .2)4 9 x 12 12x8 78 13 x 11 2)4 12x8 113 12 x 9 3)4 113 13 x 11 5)4 64 2(12 x 8) 2)4 2(12 x 8) 78 2(12 x 8) 2)4 2(12 x 8) * Recommended 6tack sixes. Tables may also be applied to 3 in. and 3 1/2 in; stack depths, b Combinations 12-d and 14-d have same capacities in Table 7 as combinations 12 and 14 respectively. Table 3. Second Story Warm Air Ducts--Double Wall Stacks and Fittings Combi nation No. Leader Pipe Di ameter, . . In. . Pipe Area Sq In. Stack Size, In. Internal External 21 8 50 2)4* x 10 3)4* X 10% 22 8 50 3 x 10 3% x 10% 23 9 64 2)4* x 12 3)4* x 12% 24 9 64 3 x 12 3% x 12% ? Commercial sizes vary 1/8 in. from values shown. Register Sue, In. Floor 8 x 10 8 x 10 9 x 12 9 x 12 Baseboard Size 10 x 8 10 x 8 12 x 8 12 x 8 Ex tension 2)4 2)4 2)4 2)4 Sidewall 10x8 10 x 8 12x8 12 x 8_ all correlated. Similarly in the case of return ducts, the selection specifies a complete unit consisting of return grille, return duct, and shoe connection. Recommended Standard Sizes For the purpose of simplification and standardization, selected combina tions of commercial sizes of warm air pipes, return air pipes, ducts, grm' fittings, and registers are .designated as Combination Numbers. numbers assigned: and'the! combinations selected as standard are listed w :the following Tables 1 to 4 inclusive.3 The selected types of fittings are shown in Fig. 2, and their resistances ex- Gravity Warm Air Systems 459 Table 4. Return Air Ducts Combi nation No. Doer Dia. In. Duct Area So. In. When Joist Space Is Used* No. of Min,b Joists . Depth Lined In. Metal-Grille Sizes Choose.One ABC When Base board Intake Area at . Shoe Con Duct Is Used fob First nection, Story Sq. In. Choose One 31 10 78 17 Sx 14 10 x 12 - 32 12 113 .1 9 6x30 8x24 12 x 14 14 x 10 ' or 2 5 4-In. Ext. 33 14 154 1 12 8x30 10 x 24 14 x 16 or 2 6- . 170 34 16 201 1 .18 :. 10x30 12 x 24 or 2 8 220 35 18 254 2 10 12 x 30 14 x 24 30 x 10 4-In. Ext. 280 36 20 314 2 12.5 14 x 30 18 x 24 340 37 22 380 2 15.0 18x30 420 38 24 452 2 18.0 20x30 500 14 x 6 12 x 8 22 x 6 16 x 8 28 x 6 22 x 8 28 x 8 22 x 10 36 x 8 28 x 10 36 x 10 30 x 12 42 x 10 36 x 12 42 x 12 36 x 14 `Based on 14 in. space between joists. " Use full depth of joist except when joist depth is less than minimum depth required, when pan mutt be uted. Fig. 2. Typical Warm Air Boots