Document MMzMQEDQkDgoQLgYO0D82XQ39

INSPECTION REPORT NESHAP 6C: Gasoline Dispensing Facility Inspection Attached please find the United States Environmental Protection Agency's (EPA's) inspection report of your inspected facility and/or any related fuel delivery inspections identified therein. EPA is providing this report as a matter of agency policy and will contact you again only if needed. Without making a determination that your business or organization is a small business, EPA is also providing you with a link to this Small Business Resources Information Sheet (https://www.epa.gov/compliance/small-business-resources-information-sheet) which provides an array of resources to help small businesses understand and comply with federal and state environmental laws. Inspection Information Inspection Number: Inspection Date(s): Regulatory Program(s): EPA Region/Program Conducting Inspection: Company Name: Facility Name: Facility Physical Location: R8_CAA_2025_0625_002 6/25/2025 40 C.F.R. Part 63, Subpart CCCCCC - National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline Dispensing Facilities (NESHAP 6C) EPA Region 8, Enforcement and Compliance Assurance Division, Air and Toxics Enforcement Branch Maverik, Inc. Maverik #5258 620 E Fillmore Street, Colorado Springs, CO, 80907 Alyson Skeens Field Inspector Name Scott Patefield Name of Approving Official Inspector and Approval Inspector Title Branch Manager Title Digitally signed by ALYSON ALYSON SKEENS Date: 2025.09.10 13:53:45 SKEENS -06'00' Signature Digitally signed by SCOTT SCOTT PATEFIELD PATEFIELD Date: 2025.09.05 11:00:22 -06'00' Signature FACILITY INSPECTION DETAILS AND OBSERVATIONS General Facility Information Gasoline Dispensing Facility Facility Name: Maverik #5258 Parent Company Name: AIRS-ID: 041-2175 CAA Permit (if any): Primary Facility Representative & Title: Facility Contact Phone/Email: Mark Stewart Sr. Environmental Engineer 801-438-4884 Mark.Stewart@maverik.com On-site Facility Representative & Title: Facility Address: 620 E Fillmore St, Colorado Springs, CO 80907 Compliance History: Enforcement and None Fuel Delivery Company Name: Trucking Company Solar Transport Company Truck Identifier: 241211 Trailer Identifier: Fuel Supply Company Representative & Title: Fuel Supply Company Contact Phone/Email: Tyler DePhillips Senior Director of Operations 515-706-3408 tyler.dephillips@solartransport.com Driver Name: Fuel Supply Company Address: Enforcement and Compliance History: 1150 Locust Street, Sute 301, Des Moines, IA 50309 None Maverik, Inc. APEN Exempt memo 20EP0454S.XP Erich Salario, Lead 257249 Caleb Kirstatter Inspection Number/ID: Inspector(s): Time Inspector Presented Credentials: Permission to Enter Facility Granted? If Yes, by whom? If No, explain. Photographer Range: Inspection Narrative: Areas of Concern: General Inspection Information R8_CAA_2025_0625_002 Inspection Date Katelyn Bergl (EPA) Arrival/ Alyson Skeens (EPA) Chris Andrade (EPA) Departure Time 6/25/2025 10:34 AM 11:55 AM 10:40 AM Announced Unannounced Yes No Administrative Inspection CBI Procedures Discussed Erich Salario, Lead Items: SBREFA Form Provided See APPENDIX A: Photograph and Video Log The facility was inspected under the Clean Air Act (CAA) for compliance with 40 C.F.R. Part 63, Subpart CCCCCC - National Emission Standards for Hazardous Air Pollutants for Source Category: Gasoline Dispensing Facilities (NESHAP 6C). Inspection activities included observation of a fuel delivery event by the EPA inspectors and a request for records required to be maintained under NESHAP 6C. None Page 2 of 4 Gasoline Throughput and Testing Records Applicable Throughput Category: Calculated based on volume of gasoline Calculated based on volume of gasoline loaded into all storage tanks dispensed from all storage tanks <10,000 gallons per month 10,000 gallons per month and < 100,000 gallons per month 100,000 gallons per month Date Applicable Throughput Category Was Exceeded: Based on records provided since July 2020, the facility exceeded the 100,000 gallons per month throughput threshold on or before June 2021. Records: All Facilities regardless of throughput 5-Year Throughput Records Available (5-year records must be maintained and made available within 24 hours of request) Notes Throughput records for this facility from July 2020 - June 2025 were provided via email by Mark Stewart on June 26, 2025. Last 12-month rolling throughput calculation Provided along with 5-year throughput records Records: Facilities 100,000 gallons per month Notes 3 -year Leak Rate and Cracking Pressure Test (CARB Date of Last Test: 6/24/2024 Results of Last Test: Pass Report Provided: Yes Test Procedure TP-201.1E, - Leak Rate and Cracking Pressure of Pressure/Vacuum Vent Valves, or Test was conducted within the last three years. equivalent) Static Pressure Test (CARB Test Procedure TP-201.3, - Determination Date of Last Test: 6/24/2024 Results of Last Test: Pass Report Provided: Yes of 2-Inch WC Static Pressure Performance of Vapor Recovery Systems of Dispensing Facilities, or equivalent) Test was conducted within the last three years. Fuel Delivery Truck Compliance (Gasoline Cargo Tanks under NESHAP 6C) Fuel Type: 1) Regular Unleaded (RUL) 2) Premium Unleaded (PUL) 3) Diesel Amount of Fuel Delivered: 1) 4,404 gallons 2) 1,137 gallons 3) 2,366 gallons Annual Certification Test - Vapor Tightness Testing - EPA Method 27 of appendix A-8 to part 60 of CAA Available with truck Date of Last Test: July 15, 2024 5-Year Test Record Availability: Available at office or central loc. Not Available Other: Results of Test: Pass Pressure Change, p: Vacuum Change, v: Pass, 0.0 Pass, 0.0 Page 3 of 4 Fuel Delivery Event Observation: A fuel delivery event was observed by the EPA inspectors. The inspectors used a forward-looking infrared (FLIR) camera to record optical gas imaging (OGI) videos of gasoline vapors, and a toxic vapor analyzer (TVA) to measure gasoline vapor concentrations1. Any auditory, visual, and olfactory (AVO) observations were also recorded. See Appendix A for a list of photographs and videos recorded during the fuel delivery inspection. Components of the refueling Description/Observations (including any OGI or AVO activity which were observed: observations) Conditions of Equipment Equipment was observed to be capped and covered prior prior to refueling event to fueling. The vapor recovery hose was first connected to the vapor Connection of fuel and vapor recovery tank and truck header. Next, the fuel hose was lines prior to fuel transfer connected to the fuel pipe of the tank, and finally the fuel hose was connected to the truck header. Maintenance of fuel and vapor line connections during fueling event Disconnection of fuel and vapor lines after fuel Hoses were disconnected in the opposite order for which transfer they were connected. Conditions of Equipment after refueling event Caps and covers were returned after fueling. Documents Requested Document(s) 5-year fuel throughput records including previous 12-month fuel throughput calculation EPA Method 27 for the fuel delivery truck Most recent NESHAP 6C Performance Tests Status Document(s) Provided Will Provide After Inspection Document(s) Provided Will Provide After Inspection Document(s) Provided Will Provide After Inspection Document(s) Denied Other Document(s) Denied Other Document(s) Denied Other Notes/ Comments APPENDIX A: Photograph and Video Log File Name Description 20250625_16460 3185_iOS.heic 20250625_17162 4357_iOS.heic Tanks capped and covered prior to delivery Annual Trailer Vapor-Tightness Test Report (EPA Method 27) Trailer 4J8T04222ST103402/257249 for Solar Transport Inc. Photographer K. Bergl K. Bergl 1 The TVA was calibrated using 500 parts per million (ppm) and 10,000 ppm methane gas standards. The methane concentrations recorded on the TVA were then converted to a ppm concentration as propane using a conversion factor of 3. This provides a conservative conversion to propane, using the guidance put forth in EPA's "Frequently Asked Questions (FAQ) for Method 25A". See https://www.epa.gov/sites/default/files/2016-08/documents/method25a_faq.pdf. Page 4 of 4