Document MMz5RJaEMQLmOVv0OVkkRzBKL
ET AD Analytical Sub-committee
Minutes of tha 10th Meeting held at Ludwigsha en/Rh. on 23rd and 2&th November, 1977
HONS 200070
ACTION
3. JT Supplements to ETAD Analysis Method 2Id (Amines in pigments and solvent-soluble dyestuffs) Remarks on various items of Method 212 in regard to the weighed portion, amount and concentration
( of extraction agent, the solvents used, detection limits, blank values, etc. have been prepared by Dr. Trautner and Dr. Rosenthal (both from Bayer) and copies of these papers will be sent to ASC members by Dr. Steuerle.
The suggestions for improvement are to be taken into account should any urgent reason for revising Method 212 arise.
4. PCB's in pigments
'
MW
77
4.1. Results of rcund-robin test to determine pCB's in ^Heliogen Blue
it.2. Discussion and decision on further action Items 4.1. and 4.2. were discussed together.
The results of the agreed ring test were summarized in a list (Appendix ASC 10.2.). This contained the results, listed according to specimen preparation and final determination. The Hoechst findings were presented at the meeting and are to be found in Appendix ASC 10.2. The results differ very greatly (extreme values 16 and 139 ppm), and no dependency was observed either Oh specimen preparation or the type of final detemana tion. At all events a large group of results, 80-140 ppm with the accent on 110, was considered to be apparently correct as it appeared possible that losses could occur in preparation of the specimens whereas, in contrast, simultaneous detection of constituents other than PCB did not appear very probable, for a variety of reasons. One of these resulted from conformity of the
HONS 200071
values found at BASF using another chlorine-specific detector, a further reason was conformity of the Hoechst values as ascertained by measuring with UV, a third reason being that the clean-up does not really influence the results. ICI and BASF found that the PCB's present in the specimens consist mainly of an isomer blend of biphenyls chlorinated six times and small quantities of biphenyls chlorinated five times. Bayer had claimed that there was a larger proportion of the latter.
The existence of oxygen-containing compounds mentioned by Bayer was confirmed in principle by BASF. The concentration of these compounds was comparatively low an3 had practically no influence on the determina tion of PCB's. According to BASF, chlorinated diber.zofuranes as mentioned by Bayer are not present, but chlorinated biphenylethers (Cl^-Cl^) are present.
In view of the multiplicity of PCB isomers and homologues, which'would be practically impossible to deal with individually, it was suggested that (at least temporarily) a screening method be developed such as would involve no undue precleaning and little effort.
In this connection, the question is put to the Technical Committee as to whether a method covering a range of
a few ppm and yet having an error limit of + 30 %, satisfies the requirements. More exact methods involve very much more effort.
The following methods were suggested: Determination following reduction with LiAlH^ using FID as biphenyl;
MOHS 200072
I. I S J J J I J J J
j ACTION
.1
J J J J J J lj
r
!J J
i
'.0
direct gas chromatographic determination using ECO.' -- 'Both to follow separation of the PCB's with n-hexane
from sulphuric acid solution in accordance with the BASF method*. Direct perchlorination by the ICI metr.cd. It was pointed out that the methods which involve reduction or perchlorination of the PCB's do not in principle indicate which compounds were originally present. This means that wrong conclusions could possibly be drawn if the results are usd without caution. On the other hand, there is the advantage that constituents which would otherwise be detected together with the PCB's are almost certainly excluded.
By offering several methods, it is possible for laboratories having varying apparatus to carry out PCB determination.
All ASC member companies at the meeting declared their
willingness to carry out five tests with each of the
three methods and using the sample of copper phthalo-
cyanine sent previously to them by BASF. Farbwerke
Hoechst will concentrate on the problem of the low
chlorinated biphenyls possibly formed from dichloro-
benzidine.
.
The question as to which stages of chlorination of biphenyl need to be determined (on which no guidance haB been received from the toxicologists) was provisionally dealt with by stating that, initially, the high-chlorinated stages from C12H gCl^ should be determined in view of greater tendency to accumulate in fatty tissue.
+The methods of determining PCB's via biphenyl or
decachlorobipheny1 had already been passed on by ACNA
and ICI to ASC members at previous meetings.
At the 10th Meeting, BASF passed on their method of
direct determination of PCB's in copper phthalocyanine
to ASC members.
HONS 200073
I I 1 J J J J J
II
11
ACM A suggests in an additional letter (22.12.77); "If possible, it would be better to aim at an extraction method useful both for the high chlorinated biphenyls in Cu phthalocyanine and for low chlorinated biphenyls (3-3-dichlcrobipheny1) in dichlorobenzidine pigments. According to our experience, this is possible following ACvIA method where PCS's are in contact with the cone, sulphuric acid only for five minutes in an ice-bath, whereas applying BASF extraction method the contact time is about 2 hours at room temperature; during this long period, about 30 X 3.3'*dichlorobiphenyl could be sulphonated (see ACNA letter to Members of ASC-ETAD 5.9.77)."
5- Accumulation of dyes in fish
*.
'
,
Dr. Steuerle reported on the efforts of BASF to obtain authorisation from MITI for two disperse dyes. The results obtained in the first test series were reported on at the 9th Meeting of the ASC. Following submission of the results of a second test series to MITI, more details were objected to than was the case with the first series, i.e.:
1. The use of commercial dye instead of pure substance which would then have had to be dispersed in accordance with the MITI rules.
2. Maintenance of the fish, in which the water-containing test substance was renewed daily and not continuously.
3. The analysis, as mackerel and not carp were used to determine the recovery factor.
Comments: Dr. Rtlttner referred to the remarks made during the visit to Japan in 1977 regarding the results of tests with water-insoluble substances.
. All member companies who had previously submitted . results of tests with disperse dyes considered
HONS 200074
LUiJ ^ i 11 Ai tj n
"'Untersuchungalaboratcrium
Fur die Sitzung ASC der ETAD am 23./24.11.77
Destimmung von PCU's in Kupfsrphthalocvanin Probe: Heliogenblau Cu-Phthalocyanin ex BASF 15.OB.1977
1^4 11. ij r
Hm 1CM
bast
tthM*
11 m?scJrti..i(uP// kitt*lf*U>vl*/<tU4llW/ UiiH^/zac-rn
11 H.s: /Ah i *// SC-liD
MB ^7/<v4>/'w;,
41
wv
PC* <e,w'
106/11) iie/ut 11V10J r*n 107/110 100/110
111 5 (tow
Cita-UiQ 1C1 Sarritl
11 kl* *Cm 1)
Hi 1C1 11
Jl Bay*- 5077/003177VOI n/>whOI((//
0C-l<l?kf//( m.) 0// iw**ft//-*> J 1 Mi
Itoltcrunf ft* %yar ))//
4ti"i3w9 1 VOW i
karitlriirv^ iwa* *01C// IUB
It iMhlll 3 *
ft Nl SiaM*t ( k
3) *jo/j'm* ir a ) 0?*-**t 5CJCC fcl a*peklftriV/0C-O
11 Suhiai T.:^t ) SwUll lllril 11 /
$*141 "!
/
JaHlit tilUn /
r^tMrir j'V'/CC*/15
It
007
*1 . 10 JO
"SEE/
Par^Mar 1 r
^ 10
1) H?;0(Ai.l>i*//*nw!*|/ fpe:
on C8 ,el>4> 7
1 .
Ill
1 2
C/)7
a) *' 41 4
>17 m
157
Ki
* sei
I k) 15 55
10 ?5
J5 o
IV 11) K) 1C)
t: t
Dl/TT'
p<
MOMS 200075
Fortsetzungi
Hoechst
1) H,SO , n-Pentan/1 GC (8v)
2) Clean up wie If
Bayer 3)
'
75 64 75
99 63 1 o2 73 1o2
75 64 75
99 63 1o2 73 lo2
HONS 200076