BCC: P. 0. BENIONUS D. A. OLSON July 1 1970 Mr. Gene Lewis P, R. Mallory Company Waynesboro, Tennessee Dear Genet X apologise for the delay, but after further travel and a long holiday weekend X am finally sending you my comments regarding the oontrol and disposal of Aroolor*. X appreciated the time you and your colleagues were able to spend with Randy Graham and me and X was pleased I had the opportunity to tour your plant, since this gave me a better understanding of your overall problem. Gene, of all the plants I personally toured, yours had the biggest challenge to reaoh the objectives we are striving for. X tell you this not to embarass you but, hopefully, to give you some feel for the magnitude of the problem. First, let us consider the welfare of your employees. Aroclors, being chlorinated hydrocarbons, should not be permitted to exceed 0.5 to 1.0 milligram per cubic foot of air In the work area. In your operation, in spite Of an operating ventilation system, the presence of Aroolor was noticeable by the blue base present and insensitive as X have become, the amount was high enough to cause eye irritation which persisted for several hours, after the exposure. Another area of employee exposure is direct skin contact with the liquid Aroolor. Contact should be eliminated by operating changes or by providing protective gloves and clothing. OSW 020419 L, STLCOPCB4008348 2 ` To prevent the escape of PCB'o to the environment calls for a level of control and housekeeping many of us have never been asked to achieve In the past* Every effort must be aside to prevent leakage and spillage* Mainte nance oust be kept at a venr high atandard. tor those areas idiere leakage and spills will occasionally occur* catch pans cunt be provided* These pans oust drain to a collecting basin or be emptied by responsible employees on a scheduled basis* Mixing of Aroclore with waste water streaas should bs avoided since separation of PCS*a froa water can be costly. If nixing cannot be avoided* a oatcb basin and settling pond should be provided to separate the heavy Arcelor froa the water* Unusable contaminated Aroelor should be disposed by Incineration vhloh assures complete destruction to COo* H7O* and RC1. Any Incineration below 800C will result in vaporisation tdilch will oontaalnato tbs atmosphere or In partial oxidation lch say yield oaterlals which are highly toxic* To help our customers with their liquid disposal pro blems* we have offered to aocept for future incineration scrap liquid Aroolors shipped to Monsanto Coopery, W* 0* Kruaarlch Plant, Saugst, Illinois, Attention! Supervisor* Department 246* The charge for this dis posal is 3i per pound of material. This charge la tentative pending a complete evaluation of incineration costs and does not Include freight or container costs* Contaainatlon of the atmosphere oust also be ellninated. All handling systems oust be closed shorever possible* Fumes exhausted froa a tank* vessel, or working area roust bo trapped and collectsd using condensers and entrainment separators* Solids contaminated with PCS'* pose a greater challenge* Until a proper incinerator la designed* we are suggesting that disposal be made in an authorised, properly operated land fill away froa any water aysteaa. These solids Include treatment elays* absorbing waterials used to contain spills, rags, windings end containers. In summary, control of PCBfs can be achieved with equipment engineered to prevent losses and maintained proparly coupled with good manufacturing practices which result in a high standard of housekeeping. DSW 020420 STLCOPCB4008349 3 From the interest and concern which you have expressed, I aa certain that you will do all you can to reduce the escape of PCS'* from your operation, Mien all of ua succeed in this objective, I an confident that no regulatory agency trill be compelled to take precipitous action regarding the use of PCBfe in vital applications. Sincerely, nst cot Hr* H* B* Vaught P. R. Kallory Coapanar Mr. Cadi Karrod P. R. Hallory Company Q R. flrahaa W. B. Papageorgs Manager Environmental Control OSW 020421 STLCOPCB4008350