Document MMVjbkQ4yR8QqOZvoeK4a14Oa

if- Air Conditioning Industrial Heating: ` Direct-Fired Heaters^ Campbell Heating Co. 3121 Dean, Des Moines 17, Iowa 3' '- WINTER-CHASER AIR CONDITIONING SYSTEMS EASTERN REPRESENTATIVE: Neil Adams, 22 Jefferson SU Lambertrille, N. J. TeL Nil 2-0655 Horxzontal Unit Heater OH cfc Gas Gas HEAVY DUTY HEATERS For Large Churches, Schools, (Up to 3,000,000 Btu) Commercial & Industrial Buildings Lo-Boy Oil Gas Fn t-d 75 F Heating Guarantee If the heating plant, design is approved by our Engineering Department or de signed by a Registered Engineer and the heater and blower are furnished by us and are in accordance with our ratings, we will guarantee the heating of all rooms to which warm air is delivered to 75 F in the coldest and windiest weather. 10 Year Durability Guarantee All Campbell Heaters installed as de scribed above are guaranteed for 10 years against repairs from any cause, parts to be furnished free f.o.b. the factory. Motor, humidifier, automatic burner and controls and other parts not manu factured by us carry their manufactur ers' guarantee of one year against de fects. Engineering Service Our Engineering Department will be glad to help the consulting engineer or architect solve any heating, ventilating or air conditioning problems or help with layouts and specifications for any large building. Our Engineering Department consists of trained graduate engineers backed by 73 years of practical experi ence. 92 8000 Series For AU Fuels 8000 Unit Heater For All Fuels Campbell Heating Co. Air Conditioning Industrial Heating: Direct-Fired Heaters SPECIFICATIONS and DIMENSIONS Unit No. * HEATER ; BLOWER* MAX. FUEL RATE5 DIMENSIONS Btu Output Capacity BTU/ Hr. f per Heating Sq Ft Surface Heat Sq Ft ing Sur fl t "S oo face Assumed External Static In. Water Motor Oil bp gpb 1000 Btu Gas cfb LP Gas gph Coal Lbs Per H in. L in. W in. Hr. U225 U275 U325 U400 U500 U600 U700 usoo U950 U1100 Hi Boy & Horizontal Unit Heater--Oil & Gas for Churches, Schools, Commercial & Industrial Buildings 225,000 275.000 83 2700 2750 83 3300 3300 Yt H Yt 2.0 280 2.8 a 2.5 350 3.5 . 6666 325,000 119 2700 4000 400,000 119 3300 4900 Y a K 2.9 400 4.0 1 3.6 500 5.0 72 72 500.000 180 2800 6100 600,000 180 3300 7300 a a 1 4.5 625 6.3 m 5.4 750 7.5 84 84 700,000 244 2850 8500 $00,000 244 3300 9800 Yt a 2 6.2 875 8.8 2 7.2 1000 10.0 99 99 950,000 333 2850 11,600 1,100,000 333 3300 13,500 H 3 8.5 1200 12.0 3 9.8 1375 13.8 108 108 48 48 54 54 60 60 78 78 106 106 23 23 29 29 34 34 40 40 48 48 Lo Boy Oil & Gas Fired for Large Residences, Small Churches, Schools, etc. H200 H250 H300 235,000 100 2350 2600 275,000 125 2200 3300 340,000 136 2500 4000 h Yt H Y 2.2 293 2.9 H 2.5 344 3.4 a 3.2 425 4.2 52 75 41 57 85 41 61 87 50 H350 H400 H500 400.000 152 2600 4600 450,000 167 2700 5300 500,000 200 2750 6600 Yt Y a 1 4.0 500 5.0 1W 4.5 560 5.6 m 5.5 625 6.2 61 87 50 61 87 50 74 91 60 H600 650,000 240 2700 8000 H700 750,000 280 2700 9200 Yk Y 2 6.5 810 8.1 2 7.5 940 9.4 76 97 72 104 60 80 8000 Series Oil, Gas, Stoker or Hand Fired^or Large Schools, Churches, etc. 8075 840,000 280 3000 11,000 8100 960,000 320 3000 12,500 8125 1,080.000 360 3000 14,100 H H H 3 7.5 1050 10.5 100 93 134 76 3 8.6 1200 12.0 114 95 153 76 3 9.7 1350 13.5 129 97 171 76 8150* 1,320,000 440 8175 ' 1,440,000' 480 8200* t, 800,000 600 3000 17,300 3000 18;000 3000 23,600 H H , 5< 5 11.8 1650 16.5 157 98 195 5 12.9 1800 18.0 171 99 202 5 16.1 2250 22.5 214 120 216 76 78 94 8250 2,250.000 750 3000 29,&H> : H 8300 8350 2.700,000 900 3000 35,400 ' H 3,150.000 1050 3000 41,300 7W 20.1 2810' 28.0 268' 120 243 . 94 m 24.1 3380 33.8 320 132 251 104 10 26.1 3940 39.4 375 150 251 114 8000 Series Unit Heater--Oil, Gas, Stoker or Hand Fired--For Large Industrial Buildings U8125 1,080,000 360 3000 14,100 Consult 2-1 9.7 1350 13.5 129 97 105 76 our U8150 1,320,000 440 3000 17,300 Engineers 2-1H 11.8 1650 16.5 157 98 118 08175 1,440.000 480 3000 18,900 if 2-1 tf 12.9 1800 18.0 171 99 130 U8200 1,800,000 600 3000 23,600 duct 2-2 16.1 2250 22.5 214 120 137 76 76 94 U8250 08300 08350 2,250.000 750 2,700.000 900 3,150,000 1050 3000 29,500 3000 35,400 3000 41,300 used. 2-3 20.1 2800 28.0 268 120 157 94 2-3 24.1 3380 33.8 320 132 157 104 2-5 26.1 3940 39.4 375 150 157 144 * A unita include Special Oil or Gas Heater, Casing, Blower, Motor, Drive, Filters, Humidifier, and Slower Control but less Burner, Controls and Built-in Combustion Chamber. 1 ype B units include as Type A plus Oil or Gas Burner and built-in Combustion Chamber and Stand ard Controls. t Based on 80% thermal efficiency for oil and gas and 70% for coal. Add 10% to 35% over calculated heat loss for pick-up load and 10% to 15% for duct radiation losses. The higher figure is preferable for best operat- t pg economy and life of the equipment. ._ : * or other air volumes and static pressures consult our Engineering Department. * An induced draft blower can be furnished if a stack or chimney is not available. The gas passages of the heaters are adequate so an induced draft blower is not ordinarily needed. For Complete Specifications, See Sweet's Catalog Service 93