Document MMQVXk62gwv71k76EMQwODJxy
462
CHAPTER 19
1955 Guide
Table 7. Warm Aik Capacitt, Btuh Delivered Second Story Registers
Actual Length (Bonnet to Boot) Feet
No. op TTON No. Elbows
C6 6H > 7.
4
6 -8
10 : 12
14 . 16
18
4 6 8 10 12 14 16 ; 16 20 4 6 a 10 12 14 16 18 20 22
-- 7M 4 6 8 10 12 14 16 18 20 22 24
11 or 22 12 or 24
14 15
8,370 10,040
8,140 9,760
7,900 9,470
7,670 9,190
7,430 8,900
7,190 8,620
6,950 8,330
6,710 8,050
6.470 7,770
6,240 7,480
6,000 7,200
a 11,710 11,380 11,050 10,720 10,390 10,060 9,720 9,390 9,060 8,730 8,400
o 16,200 15,750 15,300 14,840 14,380 13,920 13,460 13,000 12,550 12,100 11,640
11 or 22 12 or 24
14 15
-Oo 7,940 7,720 7,500 7,280 7,050 6,830 6,600 6,370 6,150 5,930 5,700 O 9,540 9,270 9,000 8,730 6,460 8,190 7,920 7,650 7,380 7,110 6,840
11,120 10,810 10,500 10,180 9,870 9,550 9,230 8,920 8,610 8,290 7,980
1 15,400 14,970 14,530 14,100 13,670 13,230 12,800 12,360 11,930 11,500 11,070
11 or 22
7,530 7,320 7,110 6,900 6,680 6,470 6,250 6,040 5,830 5,620 5,400
12 or 24
9,030 8,780 8,520 8,270 8,010 7.750 7,500 7,240 6,990 6.73C 6,47(1
14 3
10,530 10,240 9,940 9,650 9,350 9,050 8,750 8,450 8,160 7.86C 7,560
15 j-i 14,580 14,180 13,780 13,370 12,950 12,530 12,120 11,710 11,300 10,890 10,480
11 or 22 12 or 24
s :
7,120 6,920 6,720 6,520 6,310 6,110 5,900 5,700 5,500 5,300 5,100 8,530 8,290 8,050 7,810 7J70 7,330 7,080 6,840 6,600 6.36C 6,120
14 4
9,950 9,670 9,390 9.110 -8,830 8,550 8,260 7,980 7,700 7,42C 7,140
15 ii ' 13,780 13,390 13,000 12,610 12,220 11,830 11,440 11,050 10,670 10,280 9,890
11 or 22 12 or 24
14
15
5
6,700 6,510 6,320 6,130 5,940 5,750 5,560 5,370 5,180 4,990 4,800 8,040 7,810 7,580 7,350 7,130 6,900 6,670 6,440 6,220 5 991 5,760 9,370 9,110 8,850 8,580 8,310 8,050 7,780 7,510 7,250 6,98C 6,720 12,970 12,600 12,240 11,870 11,500 11,140 10,770 10,400 10,040 9,680 9,310
Notes: When floor registers are used on second story rooms, include the equivalent elbow resistance for the cross-over connection as shown in Fig. 2.
Combination Numbers 21 and 23 as shown in Tables 2 and 3 are composed of narrow stacks for narrow
stud spaces. For Combination No. 21, the capacities are the Btuh deliveries shown for Combination Nos. 11 or 22
multiplied by 0.83. For Combination No. 23, the capacities are the Btuh deliveries shown for Combination Nos. 12 or 24
multiplied by 0.83.
.Table 8.. Return Air--Carrying Capacity--Btuh Sehviced
Return Aib Combination No.
31 32 :
33 34
35 36
37 38
Duct
In.
10 12
14 16
18 20
22 24
Type A
BTUH
11,300 16,300
22,200 29.000
36,700 45,300
54,800 65,200
Types B and C
BTUH
9,500 13,700
18,700 24,400
30.800 38,000
46,000 54,800
Type D
BTUH
7,800 11,300
15,300 20,000
25,300 31,300
37,800 45,000
Type E
Type F
BTUH
7,800 11,300
15,300 20,000
25,300 31.300
37,800 45,000
BTUH
5,000 7,200
9,800 12,800
. 16,200 20,000
24,100 28,700
Return Aib Com* bination
No.
31 32
33 34
35 36
37 38
4. Show the number and proposed locations of return air grilles and the type of return-air system (see Fig. 5).
5. From Table 6, for first story, or from Table 7 for second story, select the com bination number for the warm air system which will supply the heat required to each room,.with/the number of elbows and length of leader pipe previously deter mined. Then,':using" the combination number as found, read directly in Tables L 2, of 3 the leader, statk, and register sizes required.
6. From Table 8 select the combination number for the return air system tocor-
Gravity Warm Air Systems
rftETURN AIR GRILLE
463
type; e
j "* A y pvv , Lr , A-J i UliU A ICb U1 II Oil OJf CICIUC, I CU UCO pertJetlt' for each 4 ft additional length in the horizontal run.
Fig. 5. Typical Arrangements of Return-Air Duct Systems respond with the Btu per hour serviced and the type of return air system. Then rom Table 4 select the duct and grille sizes,, etc., corresponding .to this number.
Select a furnace having a bonnet output, in Btu per.hour, one-third greater than the heat loss from the structure, to compensate for duct heat loss.