Document MMQ5NZenD79VrB3QO1NjnqKEy
TABLE 43-C
EXTINGUISHERS SUITABLE FOR CLASS B FIRES, FOR FIRES IN FLAMMABLE
LIQUIDS V INCH AND UNDER IN DEPTH
Type of Hazard
Baste Minimum Maximum
Extinguisher Travel Distance
Rating
to Extinguishers
For Extinguishers Labeled Pnor to June t, 1969 Light 4B 50 ft
Ordinary
8B
50 ft
Extra
12B
50 ft
For Extinguishers Labeled After June 1, 1969
Light
SB 10B
30 ft 50
Ordinary
10B 20B
30 ft 50
Extra
20B 40B
30 ft 50
Note For flammable liquid hazards of depth greater than Vi in, Class B fire extinguishers shall be pro vided on the bass of one numerical unit of Class B extinguishing potential per square foot of flammable liquid surface of the largest tank hazard within the area
From National Fire Protection Association Standard No 10, Table 4210
the availability of the extinguisher for such protection Scattered or widely separated hazards shall be individually protected if the specified travel distances m Table 43-C are exceeded Likewise, extinguishers in the proximity of a hazard shall be care fully located so as to be accessible in the presence of a fire without undue danger to the operator
Extinguishers with Class C ratings are re quired where energized electrical equipment may be encountered which would require a nonconducting extinguishing media This will include fire either directly involving or sur rounding electrical equipment Since the fire itself is a Class A or Class B hazard the ex tinguishers are sized and located on the basis of the anticipated Class A or B hazard
Whenever possible, electrical equipment
should be deenergized before attacking a Class C fire.
Extinguishers used for Class D protec tion and other special fires are installed ac cording to the size and type of the special hazard The type of combustible material, the quantity, and its physical form are all determining factors that must be considered when selecting the proper type of agent and the method of application
Selection of extinguishers. Operating char acteristics that make one type of portable fire extinguisher suitable for certain fire hazards may make the same type dangerous for others
The purchaser and user of extinguishers should secure on-the-job advice from fire in spection bureaus, fire insurance earners, and fire protection engineers
Choosing the right extinguisher is extremely important All too frequently cost is given more consideration than adequate protection Remember, good extinguishers are worth their cost because of the protection they give Ob viously, only extinguishers listed by nationally recognized agencies such as Underwriters' Laboratones, Inc, or Factory Mutual En gineering Corp should be purchased
Although suitable types and sizes are in stalled in conformance with NFPA Standard No 10, there is a certain flexibility that can be used to the purchaser's advantage For example, if a certain condition calls for B ex tinguishers, the required units could be ob tained by using various size dry chemical, foam or carbon dioxide (CO.) extinguishers The relative advantages and disadvantages of each of these units should be considered with respect to all the conditions in the area It is also wise to investigate the relative merits of any particular extinguisher available on the market, as the UL classification can vary widely for extinguishers of the same size but of different manufacture
The design and operating features, ease of maintenance, and the availability of repair service should be considered too If possible, actually operating and testing the extinguisher may make a great deal of difference m the final selection
The following discussion of portable ex-
(Text continues on page 1350 )
1347