Mr. N. ?, Bushell Grant Industries Ltd. 1075 Melville Street Vancouver 5, 3. C., Canada Dear Mr. Bushell: Mr. Kelley has forwarded copie3 of your letters dated Decenter F, 1964 and February 4, 1965 along with the copies of correspcnder.ce with the Alberta Department of Health. He asked that I write you and discuss the dust situation in general. I will discuss the dust situation as I knew it in the U.S. and hope you will be able to aDoiv sc~e of this to your own situation. In general, the dust control cam be broken down to two separate situs tions. 1. Inside the plant - that effects the -orv.crs and other picuL-. personnel and housekeeping. 2. Dust eject-sd outside the plant into the atmosphere and neignborhood. This effects your neighbors. In both cases the Health Department is or can Lq involved ur.d there nay or r.av not be lavs involved. But I will revi ?v thu nature or the vouuculrte dust itucir. VerrrrcuLite itself hss been reported to contain vo free si Lien or a very small percent. It is considered by most authorities chat Jusc^ which contai>: lcc-s than 5% silica do non c<iuae siljnukik. _I_ 000992four.-* the following reports in our files: A sample checked in 194c by the Bureau of Industrial Bygene, Department of Health, Commonwealth of Pennsylvania, showed no free silica content. This sample va3 taken from a rafter Mr. N. F. Bushcll -2- February 9, 1565 2. A samp1 of vemicullte uubtr.itted in 1947 to the Industrial Hygiene Foundation of Aiuerica, Inc., Pittsburgh, Pennsylvania was checked and reported as 2% free silica. It does not state where the sample was obtained. A copy of "Dusts, fumes and mists in Industry" published by the National Safety Council is enclosed which contains seme very good information. The threshold limit or concentration of dust for verraicuiite is 50 mppcf and for asbestos 5 mppcf (million particles per cubic foot). Vermiculita is classified as a nuisance dust whereas asbestos is usually considered as a health hazard unless the dust is controlled. This is all explained well in the above report. The point I am making is that Libby venr.iculite does contain a small amount of asbestos dust. There is none in the Louth Carolina vermiculite. The Montana State Board of Health in checking the dry mill dust at Libby has set a safe limit at 20 mppcf if I remember correctly. Earl T<ovick can confirm this. In my opinion the plants using Libby ore "hould also adopt this limit for areas where men have to work. About three years ago in Louth Carolina ve started having all employees x-rayed once a year and when a new employee is hired. As far as I ;mow we have never had any negative reports on any of our people nor do I know of any reports from plants using the Louth Carolina ore. Some of our men have worxeU in the mill for 15 years. There have been raports at Libby of con having i ulmonary trouble. I also believe western Mineral Products have had a report or two. I'm sure Earl Lovic.t will cover this in his letter. We have adopted the position that ANY DUET is a health hazard and should be kept within a cafe limit. are attacking this problem by several methods. 1. Design and installation of bigger and bettor dust collection equipment at our mills and expanding plants. 2. Trying to eliminate ns much dust as possible at the mills but this is one which -v*".! help but not solve the dust pr:>tl,,n at the plant. Mo matter how clean the ore appears to be at the mill, the hnndlinr,- loading, rehandling and :>:pansion piv> ?uces irero durt. 3. Where we do have a dust problem not yet solved by mechanical improvement be sure the dust mask is worn. This is especially G000993 Mr- H. P. Busholl -3- Pobruary 9, 1965 true In our dry alii areas at the two Bills when working with mixed products such as Acoustical Plaster and when unloading ore by payloadsr- 4. We already have a dust sampling unit at Libby for checking the dust concentration and Z aa buying one for use at South Carolina and to check our plants with. 5. We are having all plant employees x-rayed once a year - trying to have them checked by the sane doctor so he can pick up any change. Hot only do we want to know about our employees but we do not want to hire someone who already has a respiratory disease. 6. And last but not least have a good repair and maintenance program to keep the equipment we have in good working order. Zn designing new expanding plants, we are designing for duat control. Pirst of all we are abandoning same cf our old obsolete plants and building new ones. There are two main ideas followed hers. 1. Divide the plant into 3 separate areas and confine any dust generated in these areas to the local area. These 3 areas arei . ore storage, furnace room, bagging and warehouse area. Each should be sealed from the other. Silos are the best ore storage for.dust control. 2. Kncloae duat producing points and install sufficient dust collection equipment. With some existing plants it may be as costly to try and obtain good dust control as it would be to rebuild. However, in most plants a great improvement can be made by re-designing the dust collection equipoont and extending it to include all points of dust generation. This is especially true on the Model "A" furnace. This would include replacing the present fan with one twice as large, enlarge the dust vent pipes, and extend them to include all points. Tor instance, the furnace discharge chute should be completely or almost completely enclosed. Do you have good collection at the ore hopper? You can find most of your points of insufficient collection when running Masonry Pill as -I'm sure you are aware of. Once the dust is collected there must be a way of disposing of it. The cyclones should be foBowed by at least a dry Vortex collector where there is no neighborhood or laws limiting it. This does fairly G000s94 Mr. N. F. Busholl -4- February 9, 1965 good collecting the dust but doesn't keep the Masonry Fill ssoke from going into the atmosphere.. Where the neighborhood relations or laws limit the dust ejected into the outside a wet collector should be installed. This brings me to the second situation as mentioned in the second paragraph of the first page. Z am attaching a few articles that presents the picture in the U.S. very clearly. There are very tight laws in some states like New York and California whereas some states have none. Each area should be investigated for city, county and state laws. The U. S. Federal Government is now getting into the act. I'm sure that it will not be long until there will be very strict laws in almost all areas. It is much better to stay ahead of them and act before they do. Frankly, we will have no other choice before long. It is my opinion that trying to save a few dollars on installation of the initial dust collection equipment will be a poor investment. I may have been too general and not answered your questions. When you receive Sari Lovick's letter and you still have questions, please do not hesitate to write or contact us again. I'm sure we do not have all the answers. w do realize we have a twofold problem and we are working to solve these as fast as our capital and time permits. The next time you are in the area I suggest you visit our Weedsport, New York plant. This is our latest Model "A" plant and where we are trying to get control of the dust both inside and outside. At the moment we have not installed a wet collector but plan to do so this year. The D-16 installation at Newark, California represents the latest in this furnace design. Here we have tried to design a good dust collection aystem. Again this was a dry Vortex collector by local choice of California Zonolite. Sincerely yours, ZONOLITE DIVISION W. R. GRACE A CO. OFSintr Attachments 0. r. Stewart