Document MMJ1zBz62pmGn7xXxJ8NY5x
T
HEATINC VENTILATINC AIR CONDITIONING CUIDE 1944
hour per square foot for each degree Fahrenheit temperature difference between the gases and surrounding air.
DOMESTIC CHIMNEYS
Experience has shown that the chimney sizes given in Table 1 are in
general adequate for heating boilers and furnaces with the capacities
indicated, when such devices are hand fired and that chimneys of these
sizes are likely to be architecturally congruous with houses or buildings
which require heating devices of such capacities.
<
Sometimes it is desirable to use a smaller or shorter chimney than that indicated in Table 1. In such cases it is necessary to estimate whether
- - *v
2D 30 35 40 45
POUNDS OF COAL BURNED PER SQ FT OF GRATE SURFACE PER HOUR
Fig. 4. Draft Required at Different Rates of Combustion for Various Kinds of Coal
a chimney of limited height can be made to produce sufficient draft in the particular case or whether mechanical draft must be employed.
It should be remembered that mechanically fired devices, oil burners and stokers, are equipped with blowers so that, with these devices, the chimney is not required to overcome the resistance of a fuel bed. Never theless, a draft in the fire box, of about 0.03 in. of water is considered desirable so that any small openings in the fire box or flue passages will result in leakage of air in, and not leakage of combustion products out, of such parts. This is not to be taken to condone leaks in fire boxes. Such leaks adversely affect plant efficiency.
OBSERVED TEST PERFORMANCE The observed performances of some brick chimneys are given in Tables 2 and 3*. The tests on which these data are based were made at various outside
Observed Performance of Some Experimental Chimneys, by R. S. Dill, P. R. Achenbach and J. T. Duck (A.S.H.V.E. Transactions, Vol. 48, 1942, p. 351).
192
CHAPTER 9. CHIMNEYS AND DRAFT CALCULATIONS
temperatures as shown and, to make them comparable among themselves, the observed drafts were corrected to 32 F, 1 atmosphere pressure, by
the formula:
where Si = computed static (theoretical) draft, experimental conditions. St *** computed static (theoretical) draft, standard conditions.
0i = observed draft, experimental conditions. Os -- observed draft corrected to standard conditions.
Table 1. Recommended Minimum Chimney Sizes for Heating Boilers and Furnaces3
Warm Air Furnace
Capacity in Sq In. of Leader
Pipe
Steam Boiler Capacity
Sq Ft of Radi
ation
Hot Water Heater Capacity
Sq Ft of Radi
ation
Nominal Dimen
sions of
Fire Clay Lining
in Inches
Rectangular Flue
Actual Inside Dimensions
of Fire Clay Lining
in Inches
Actual Area Sq In.
790 1000
590 690 900 900 1,100 1,700 1,940 2,130 ' 2,480 3,150 4,300 4,600 5,000 5,570 5,580 6,980 7,270 8,700 9,380 10,150 10,470
973 1,140 1,490 1,490 1,820 2,800 3.200 3,520 4,090 5,200 7,100 7,590 8,250 9,190 9,200 11,500 12,000 14,400 15,500 16,750 17,250
8^x13
7x11>4
13x13 HMxiiK 8^x18 6&xl6K
13x18 11Kx16M
18x18 15Jxl5J 20x20 17^xl7M
20x24 24x24
17x21 21x21 24x24>
24x28b 28x28b
30x30b 28x32b
81
127 110
183
248 298
357 441 576
672 784
900 896
Round Flue
Inside Diam eter of Lining
in
Inches
Actual Area Sq In.
10 79
Height in Ft Above Grate
35
12 113 40
15 177
45
18 254 50 20 314
22 380 24 452
55 60
65
27 573
This table is taken from the A.S.H.V.E. Code of Minimum Requirements for the Heating and Venti
lation of Buildings (Edition of 1929). bDimensions are for unlined rectangular flues.
It will be noted that the observed draft exceeded the computed static draft during some observations on the shorter chimneys. This is mainly attributed to the draft producing effect of 'the hot gases immediately above the chimney. By means of a manometer it was found that a measurable draft existed in this gas column for some distance above the chimney top. However, the temperatures in the chimney were measured with unshielded thermocouples and the actual gas temperatures may have been higher for this reason than the observed temperatures on which the computations of draft were based. The tests were made in calm weather.
193