Alliance for
war
A specially developed process for treating waters from a vinyl chloride polymerization plant will be demon strated before year's end by B. F. Goodrich Chemical (Cleveland), when it starts up its new PVC plant near Pedricktown, N.J. The process, is one of the first fruits i of a joint pollution abatement effort by industry and government.
And though the new process equip ment is still being installed* the main features of the new plant were de scribed last week at the 42nd annual conference of the Water Pollution Control Federation (WPCF). The sixday meeting--held last week in the Memorial Auditorium of Dallas, Tex., and attended by 3,600 engineers, sci entists, industry executives and gov ernment officials--was billed as "the largest single gathering on water pol lution control in the history of the fight for clean water."
Cooperation Vital: The tenor of several papers at the meeting made it clear that the sort of industry-
overnment alliance that produced he new PVC plant waste treatment plan will be seen frequently in the I future. In fact, John Gillis, senior vice-president of Monsanto (St. Louis), said such cooperative efforts would be the only way to reduce the nation's water pollution control prob lem to manageable proportions by '80.
"Stiffer pollution control laws are the trend of the times," Gillis said in chiding industries that have opposed such laws. By offering cooperation, Gillis said, business would gain an op portunity to "participate directly in the framing of meaningful laws and local water quality standards." And he suggested that more rigorous laws would help justify expenditures for pollution control equipment.
Gillis said it's probable that "the manufacturer of a new product will be required to account for that prod uct's ultimate disposal." He pointed out three possibilities for acceptable disposition of used products: perpet ual reuse, conversion into other use ful forms, or neutralization in a non polluting manner.
In proposing a government-industry coordination conference, the Mon santo executive listed three questions
that he felt should be resolved: (1) Just what are the pollution abatement goals for '80? (2) Do we have tech nological ability to meet those goals? (3) How much will the nation pay for an improved environment?
Plant Preview: Cost of Goodrich's effluent-treatment system will be more than $1 million. That's a big hunk of the $ 15-million total cost of the PVC plant now being constructed at Ped ricktown, across the Delaware River from Wilmington, Del. The com pany was granted $364,900 by the the Federal Water Pollution Control Administration for developing tne~systerrr Goodrich has agieed--that- for 1 one year after startup it will show the treatment unit to industry observers approved by the agency (CW Tech nology Newsletter, Apr. 26).
It took two years of laboratory and pil&t-plant studies to develop the sys tem. Both chemical and biological me thods_will be used to treat wastes from the PVC plant, which wiTTpro-
polymerization resins by Pechiney-St. Gobain technology. The plant's liq uid wastes, estimated at 800,000 gal./day, will contain vinyl monomers and polymers, organic and inorganic salts, organic acids, fine solids, dispersants, wetting agents and catalysts.
No comprehensive system for treating such wastes had previously been developed, although about 30 PVC plants now operate in the U.S.
Doubly Regulated: The Goodrich plan will be subject to the regulations of New Jersey's Dept, of Health and of the Delaware River Basin Com mission. Minimum requirements: sec ondary treatment and 90% removal of biological oxygen demand (BOD).
According to Goodrich environ mental engineers W. C. Holhrook and John Lank, the company used effluent "samples from Goodrich's existing PVC plants in checking out a variety of possible treatment methods. How ever, because of recent improvements in plant design, it was estimated thatwater use in the new plant will be 20% less than in any existing plant. The expected effluent volume (800, 000 gal., day) includes all process wastes, utility water, storm-sewer drainage from areas subject to acci-
FEDERATED ZINC DUST
comes in a variety of blends
and packages
TAKE YOUR PICK
Federated zinc dust gives you double value... the right blend of zinc dust for your coatings plus the right package for your production. You can rely on Federated for special blends, prepared by our zinc dust specialists to make sure you get the best one for your specific application.
Available in several grades and sizes, Federated zinc dust is shipped in quart cans, double-compartment cans, gallon cans in varying weights or in 300- or 500pound drums. If you need a particular size or type package, we'll give it to you.
Special controls ensure the quality of all Federated zinc dust. Write for informa tion, technical help or samples.
Federated Metals Division
AMERICAN SMELTING i AND REFINING COMPANY
120 BROADWAY, NEW YORK, N. Y.10306
DSW 552393
October 18, 1969 CHEMICAL WEEK 105
STLCOPCB4090810
Your product's fine
lr
I-
quality deserves top quality
packaging
This is Ohio's Five-Point Qual ity Prescription for Cor-Wal lined steel shipping containers to meet your most rigid con tainer requirements: 1) We care fully evaluate your product. 2) We select the most effective and economical materials. 3) We carefully pretreat the steel. 4) We develop the best technique for applying the lining to the steel. 5) We exercise precise control over all operations.
Your quality product deserves the best. You'll never know how good Ohio quality is, nor how well we can serve you until you give us a chance.
Call or write today.
The
Ohio
Corrugating Company
STEEL SHIPPING CONTAINERS
1301 Pine Avenue, S.E., Warren, Ohio 44481
Phone: 216/399-1894
TWX: 810/436-2666
Hatlo's They'll Do It Every Time
106 CHEMICAL WEEK October 18, 1969
.1 V <4 \W< VV|I
dental, spills and from tank-farm
diked areas, and some allowance for
expansion of plant capacity.
Composition of the wastes: BOD,
720 mg./liter; chemical oxygen de
mand (COD), 1,285 mg./liter; total
solids, 2,000 mg./liter; and sus
pended solids, 1,000 mg./liter. Great
variations from these average levels
are expected, so the company is build
ing a 950,000-gal. waste-equalization
holding and mixing tank.
Speeding Up the Settling: For pri
mary treatment of the milky white
wastes, Goodrich engineers tried set
tling, dissolved-air flotation and
chemical coagulation.
Flotation (to produce a waste prod
uct that could be skimmed off) was
ruled out, Holbrook said, because it
produced a fragile floe and didn't re
move enough solids. About 48% of
the suspended solids would settle out
unaided; Goodrich found that the use
of a ferric-ion salt with certain coagu
lant aids could boost the removal rate
to 95%, with a settling time of 30-60
minutes.
The Goodrich team found that the
optimum dosage level of the ferric
salt is about 150 mg./liter. This co
agulant should be mixed into the
effluent before a coagulant aid--such
as Calgon 227 or Nalco 670--is
added.
Secondary Sequence: BOD reduc
tion of the primary waste stream
is dealt with in the plant's secondary
treatment. One technique--adsorption
on activated carbon--was dropped
because the waste contains water-
soluble, long-chain organic soaps that
greatly reduce the carbon's adsorption
capacity.
So the company turned to biologi
cal treatment. Three such methods--
trickling filters, aerated lagoons, and
contact stabilization---were tested and
found wanting. The successful meth
od: mixed activated-sludge treatment.
But to make it successful, certain
latex solids first have to be removed
from the sludge; caustic soda must be
added to the sludge to maintain the
proper pH and prevent bulking; and
nitrogen and phosphorus nutrients
have to be added to support bacte
rial life. Final sludge output: 23 cu.-
yds./day.
One further recommendation by
Holbrook: install a centrifuge to de
water the sludge, thus reducing the
landfill disposal problem.
END
DSW 552394
STLCOPCB4090811
i^ONMENT
How to keep watch on
f what goes up the stack
" "When the air pollution emphasis
switches from what's in the air to
what's going up the stack, the stack
gas monitor will be a vital instru
ment."
""
And the chemical company execu
tive who so tersely summed up this
situation predicts that the most im
portant role for these instruments will
be as controls for the processes that
absorb or convert the sulfur oxides
in stack gases. But, according to the
users, the monitors are a long way
from filling that role.
The instrument that will do both the
measuring and controlling jobs will
probably evolve from the various in
frared and ultraviolet instruments now
on the market. But first the industry
will have to overcome such serious
problems as capturing representative
samples, nullifying interference from
other gases and particulates, offsetting
the effects of high temperatures in the
stack, obtaining consistent readings,
and reducing the relatively high costs
{table, below).
The manufacturers of both families
of instruments agree on one
these problems will be jtvgfcome. In
the infrared group are Beckman In struments (Fullerton, Calif.), Mine Safety Appliances (Pittsburgh), Re search Appliance Corp. (Allison Park, Pa.), and Leeds & Northrup (Phil adelphia) . In the ultraviolet corner are Barringer Research (Toronto, Ont.) and Du Pont's Instruments Division (Glasgow, Del.), And coming on strong is the "little black box," an electrochemical transducer device made by Whittaker Corp.'s Narmco Research & Development Division (San Diego, Calif.).
Best Customers: "Our best .cus tomers are the power generating plants and the developers of systems to con trol sulfur emissions," says a spokes man for one instrument manufacturer.
The systems developers with most experience in monitoring stack gases are the Tennessee Valley Authority and Combustion Engineering. At TVA's Shawnee plant near Paducah, Ky., a dry limestone injection process for the absorption of sulfur oxides has been operating since mid-May.
one 175-mwT' tier of the 10nit plant, Du Pont's Model (10 photo-
ic analyzer is being used at six
into a 6-in. breach in the stack goes Barringer's instrument to monitor S02.
different points. The instruments are on loan from the manufacturer.
How well have they operated? "It's still too early to give any definitive judgment," says a process control en gineer for TVA. But he concedes there have been problems. Chief among them was conditioning the samples taken from the stacks so that accurate readings (i.e., free from interference) could be taken.
"According to the wet-chemistry samples we test just to check the in struments, these monitors are not quite as efficient as we would like," says the TVA spokesman, "but using monitors seems to be the thing to do now."
Kansas Case: Combustion Engi neering's experience echoes that of TVA. A Du Pont unit has been used at its wet-dolomite scrubbing opera tion on Union Electric's Meramec in stallation {CW, July 5, p. 46). And both Du Pont and Leeds & Northrup instruments are being tried on the 125 mw. boiler owned by Kansas Power & Light, in which CE has in stalled its absorption equipment.
"The instruments work well," states Art Plumley, CE's assistant manager for chemical process development, "but they are not free of problems. The problems with both relate to get ting the sample to the instruments."
At KP&L the instruments are on two stacks. There are two Du Pont analyzers ahead of the scrubbers and two after. The two L&N instruments are placed after the scrubbers, with
August 2, 1969 CHEMICAL WEEK 31
DSW 552395
STLCOPCB4090812
A long way between waterholes ?
Starting off cross-country isn't as perilous here as some places, but when you have a load of goods you've promised to deliver and a breakdown occurs -- help disappears like mirages in the desert. But if your driver is behind the wheel of a Nationalease truck, the nearest of our 250 servicenters, located coast to coast in the U.S. and Canada, will provide the same effective, fast service you get at home base. If the truck cannot be repaired quickly, another one may be made available to get your cargo rolling. Another advantage of renting or leasing CHEVROLETS or other top trucks from us. Give us a call. We are listed in the Yellow Pages, or write:
cNational Truck Leasing System
Serving principal cities in the United States and Canada 23 E. Jackson Boulevard / Suite K-8 Chicago, Illinois 60604
32 CHEMICAL WEEK August 2, 1969
ENVIRONME NT' ; '
~
--M.-
manual readings taken before, .
"So far," says Plumley, "our best
readings are from our manual instru
ments." But he points out some ex
tenuating circumstances. "We have
been using the monitors for only a
couple of months, and during that
time we kept changing the combina
tions to test our own process."
How They Work: Both the ultra
violet and infrared instruments are
based on the absorption of a specific
wavelength of light by the substance
being measured.
Typically, Leeds & Northrup's in
frared monitor has a probe in the
center of the stack to take samples,
which are than transported by tubes
and conditioned for the analyzer.
MSA has two infrared models: the
more sensitive and expensive, Model
200, is for gases from the low-sulfur
fuels burned in power plants, and
Model 300 would be used in the
stacks of sulfuric acid plants.
Research Appliance has developed
a stack-sampling device intended to
overcome the difficulties in obtaining
a representative sample.
Du Pont's analyzer grew out of 25
years of development of ultraviolet
process control equipment (CW, July
5, p. 39). Rays from the light source
pass through a sample. A portion of
the light is absorbed by the pollutants,
and the remaining light continues into
the photometer. There, the difference
between the two light-intensity read
ings is deemed proportional to the
S02 content in the sample.
Barringer Research has a relatively
compact instrument (40 in. long).
Its 20-in. probe can be put into a
6-in. breach in the stack wall (photo,
P- 31).
Black Box: "We recommend Beck
man simply because we have had more
experience with it," says a spokesman
for the National Air Pollution Control
Administration. "But the best bet for
the future is Narmco's electrochemical
transducer. It's simpler, cheaper and
smaller (6x6x9 in.)." Pollutant gas
molecules diffuse to the surface of the
sensing electrode, setting off an elec
tric current that is directly propor
tional to the gas concentration.
Summarizes the NAPCA spokes
man: "Right now, wet-chemical tech
niques are the best and most reliable,
but to control the recovery and absorp
tion processes we're going to need
reliable monitors."