American Society of. Heating and Ventilating Engineers &uide, 1931 The average value of the product of C0 and W is about 141,000 B.t.u. To obtain the fuel saving from formula (14) in terms of barrels of oil, divide the result by 42, the number of gallons of oil in a barrel. If gas is the fuel burned, the annual saving in cubic feet of gas can be estimated by the following formula: where (U-Ui)XNX(t-h)XA *g -- r v n---------------------------- Cg x Jig U") Fg = annual fuel saving in cubic feet of gas. Cg = calorific value of gas in B.t.u. per cubic foot (usually taken as 535 for manufactured gas and 1,000 for natural gas). Eg = overall efficiency of the heating system for a gas-fired furnace (usually taken as 80 per cent). It should be understood that the heating efficiencies of 60, 70 and 80 per cent, which are frequently used for estimating fuel savings with coal, oil and gas are approximate values and apply more specifically where the heating plant is not located in the building heated, and consequently, where there is no regain of the sensible heat of the flue gases, and where the pipe transmission losses may be considerable. Where the heating plant is located within the building to be heated, the house or building efficiencies, for coal, oil and gas may be substantially higher than those specified, although it is even possible that the efficiencies may be lower than these values under varying conditions of operation.. Radiation Saving^-' The installation of a given thickness of insulation in the walls and/or . roof of a building will reduce the amount of direct radiation required to maintain the desired temperature, and in many cases'this may be an item of considerable importance; in fact, in the case of certain uninsulated constructions having a high rate of heat transmission, the monetary value of the saving in radiation due to the application of the insulation, may be | sufficient to offset the cost of the insulation. The amount of radiation that can be saved is of course determined from the difference in the radiation . requirements of the uninsulated and insulated buildings. The radiation ; saving can also be estimated by means of the following formula, if a steam heating system is to be installed: where n _ (H -- Hi) X (t to) X A Rb------------ \~240--- -------- ria\ ' (16) . Re = saving in square of equivalent radiation based on a steam heating system. to = the outside temperature on which the design of the system is based. If in the example on page 42, the temperature t0 is 0 deg. fahr., the saving in radiation for a steam heating system will be: (0.30 - 0.15) X (75 - 0) X 10,000 Ra ~ . 240 = 468 sq. ft. of equivalent direct radiation. 44 Chapter 3--Heat Losses by Transmission Table 9. Coefficients of Transmission (U) of Solid Brick WallsI> TirSSg COEFFICIENTS ARE EXPRESSED IN B.T.U. PER HOUR PER SQUARE FOOT PER 1 DBG. FAHR. TEMPERATURE between the air on the two sides and are based on an outside wind -n,. values of U m this-Table are based on thefollowmq Internal Conductivities or Conductances which are expressed m B.t.u. per Hr. per Sep Ft. per 1^ ^ Cement Mortar Plasterboard Raster (Gypsum) Wood Lath + Plaster per i- Per, ZVL Per 1 2.00 as applied Cork board Eiqid Insulation (Boardform) per . 0.55 per l Cellular Gypsum (18 ) *!! p'r ,, Flaked Gypsum, Dry (M*) 0.4B per l Split FurrinqTile lx 81 * ^ 2.-1.15 ^-------- 4--' V- Thickness of Insulation where specified w<u interior Ji Construction t Plain Walls -hlo Interior Finish 2 j Plaster on Brick. 3 1" Plaster on Metal Lath - Furred A iPiaster on Wood Lath - Furred 5 j Plaster on Plaster board - Furred 4" Plaster on Wood Lath on 2" Furnnq 6 Strips -Cellular Gypsum F\U X Plaster on Wood Lath on * Furnnq 7 Strips -- Ftalced Gypsum F\U 8 x Plaster on Giqid. Insulation (Board form) Furred 8 10 ~ Plaster on Cork board set in ^ Cement Mortar II X Plaster on it Split Furnnq Tile set 12 aqainst Wall x Plaster on 2" Split Furnnq Tile set 13 aqainst Wall Thickness of ferick -X Y& A IZ` e is." c 0.385 0.285 0.238 0.35fe 0.Z6I 0.230 0.277 0.216 0.208 0,227 0.184 0.178 0.251 a o.ni a f 0.154 o.i8i ?. V 0.148 iF 0-127 2- 0.105 0.284 0.208 0.178 0.151 0.135 0.137 0.124 0. \(o(o 0.146 0.132 0-120 0.115 0.104 0-087 ' 0.080 0.231 0.185 0.277 0:227 0.182 *Based on 1% in., the actual thickness of 2 in. furring strips. bThe coefficients on this page can.also be used with sufficient accuracy for the Ideal Rolok-Bak Wall. cThe coefficient used for cellular gypsum, 0.59 is for 18 lb. weight--heights as low as 12 lb. may be used. 45