Document MM94eRKBYL6M4vrE32Zd7bnvz

FROM R. E. PODHORA INDUSTRIAL HYGIENE DEPARTMENT POINT COMFORT OPERATIONS 1978 August 04 TO | MR. THOMAS B. BONNEY UG 7 )97p PITTSBURGH OFFICE cc: Mr. R. M. Rose Mr. F. J. Mabry Mr. G. Gehlhoff/Mr. G. L. Williams Mr. D. J, Fisher/Ms. K. M. Johnson Mr. Leslie Pfeil Mr. Chase Phillips/Mr. L. Stringham Ms. Edna Wagner X RE: ELIMINATION OF UNNECESSARY USE OF ASBESTOS CONTAINING MATERIALS This is to acknowledge today's receipt of your captioned letter dated 1978 July 28. We at Point Comfort have been working toward the goal of eliminat ing the use of asbestos containing materials since December, 1974. There are still a few uses in the plant where good substitutes are difficult to find and your assistance will be greatly appreciated. One such area is the use of Marlnite for molds at Ingot Casting. Some plants such as Wenatchee and likely others are having their Marlnite cut outside their plants. Has a satisfactory substitute for Marlnite been accepted? We are currently working with our Purchasing Department and Fiberfrax to obtain suitable substitutes for 1/32" and 1/8" asbestos sheet for furnace flow cone wrapping, trough covers, etc. We are also developing a training program|for maintenance personnel and others who are involved with jobs such as old insulation removal. Attached are copies of two letters describing our recent efforts. Our Insulating Department has developed some good practices which should be helpful to others in similar jobs at other plants. If procedures such as ours have not been developed at other refining plants or where large volumes of insulation are used, perhaps the attached material may be of some benefit. We will comply with your request to survdy the plant and plan to submit the results by 1978 September 01. REPsvh Attachments (copy of Mr. Bonney's letter to all carbon copy recipients.) B ALCOA APC 003706 r<4SM 1 FROM: R. M. ROSE/RUDY PODHORA POINT COMFORT OPERATIONS TO: MANAGERS, SUPERINTENDENTS, and DEPARTMENT HEADS POINT COMFORT OPERATIONS 1978 July 10 cc: Mr. Bobby Sowders & On-site Construction Superintendents RE: INSULATION REMOVAL AND DISPOSAL It was brought to our attention 1978 June 28, by members of the insulating department and Bobby Sowders that craftsmen such as pipefitters, mechanical maintenance personnel and others were observed removing insulation from pipes or vessels without the knowledge of the possibility of asbestos in the insulation. The removal of insulation, in most instances, is being done without tne proper protective equipment and the craftsmen are using improper disposal procedures for the debris that is generated from this process. Our insulators have been trained to properly handle asbestos materials and, therefore, work under the policy that all insulation contains asbestos until determined otherwise. In order to maintain compliance with Federal Regulation No. 1910.1001 (asbestos) and to avoid asbestos exposures, the procedures used by the Insulation Department are to be utilized by others who need to remove insulation for one reason or another. These procedures are generalized below: 1. To avoid unexpected and unnecessary asbestos exposure, assume that all insulation contains asbestos. 2. Before demolition or insulation removal is started, all personnel are to be properly protected with NIOSH approved respirators and proper protective clothing, such as disposable coveralls and gloves, head and foot covering. 3. A small sample of the insulation is to be submitted to the Industrial Hygiene Department for microscopic analysis for asbestos. You will be advised whether the insulation contains asbestos or not. 4. If the insulation contains asbestos and whenever conditions and circumstances permit, the insulation should be soaked with water to eliminate or minimize dust generation during demolition. 5. Debris from demolition is to be cleaned up as follows: a. Using the above re spiratory protection and protective clothing, all asbestos debris is to be promptly cleaned up and put in plastic bags, sealed, and then deposited in the special asbestos disposal Dempster bucket. It is essential that asbestos debris be promptly cleaned up to minimize the amount of dust that can become airborne by the wind. b. The asbestos is then buried in the solid waste disposal area. 6. Good housekeeping procedures are to be follow#^ R. M. ROSE/R. E. PQDHORA RMR/REP/mg AFC 003707