Document MM8y0ka8E3yNYgyYX29knd9Kk
American Society of Heating and Ventilating Engineers Guide, 1937
Temperature Deo F
Table 1. Properties of Dry AiRa Barometric Pressure 29.921 In. of Hg
Weight Pounds per Cu Ft
Ratio op Volume to Volume at 70 F
Btu Absorbed bt One Cu Ft Dbt Air per Deo F
Co Ft Drt
Am Warmed
One Deg per Btu
0 i 20 30 40 SO 60 70 80 90 100 110 120 130 140 150 160 180 200, 220 240 260 280 300 350 400 450 500 550 600 700 800 900 1000.
0.08633 0.08449 0.08273 0.08104 0.07942 0.07785 0.07636 0.07492 0.07353 0.07219 0.07090 0.06966 0.06845 0.06729 0.06617 0.06509 0.06403 0.06203 0.06015 0.05838 0.05671 0.05514 0.05365 0.05223 0.04901 0.04615 0.04362 0.04135 0.03930 0.03744 0.03422 0.03150 0.02911 0.02718
. *
0.8678 0.8867 0.9056 0.9245 0.9433 0.9624 0.9811 1.0000 1.0189 1.0378 1.0567 1.0755 1.0946 1.1133 1.1322 1.1510 1.1701 1.2078 1.2456 1.2832 1.3211 1.3587 1.3965 1.4344 1.5287 1.6234 1.7176 1.8119 1.9064 2.0011 2.1893 2.3784 2.5737 2.7564
0.02077 0.02030 0.01986 0.01944 0.01905 0.01868 0.01832 0.01798 0.01765 0.01733 0.01702 0.01672 0.01643 0.01616 0.01589 0.01563 0.01538 0.01490 0.01446 0.01403 0.01364 0.01326 0.01291 0.01257 0.01181 0.01114 0.01054' 0.01001 0.00953 0.00908 0.00833 0.00769 0.00713 0.00668
48.15 49.26 50.35 51.44 52.49 53.36 54.44 55.62 56.66 57.70 58.75 59.81. 60.86 61.88 62.93 63.98 65.02 67.11 69.24 71.27 73.31 75.41 77.46 79.55 84.67. 89.67 94.87 99.01 104.93 110.13 120.05 130.04 140.25 149.70
Compiled by W. H. Sevems, based on the instantaneous specific heats of air. The values for the heats
and for the cubic feet warmed one degree are for the temperatures stated and are not true over a tempera
ture range of more than one degree above or below the temperatures stated.
4
Chapter 1--Air, Water and Steam
Table 2. Properties of Saturated Ama Weights of Air, Vapor and Saturated Mixture of Air and Vapor at 29.921 In. of Hg
Temp.
FDeg
Weight in a Cubic Foot op Mixture
Wright of Dry Air Pounds
Weight of Vapor Pounds
Total Wright of Mixture
Pounds
Btu Absorbed
bt One Cubic Foot Sat. Am per Deg F
Cubic Feet Sat. Am Warmed One Deg per Btu
Specific Heat Btu per Pound
op Mixture
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 ' 190 200 210 , 212
0.08622 0.08431 0.08244 0.08060 0.07876 0.07692 0.07503 0.07307 0.07099 0.06877 0.06634 0.06361 0.06057 0.05712 0.05317 0.04863 0.04339 0.03733 0.03033 0.02228 0.01298 0.00230 0.00000
0.000068 0.000111 0.000177 0.000278 0.000409 0.000587 0.000828 0.001151 0.001578 0.002134 0.002851 0.003762 0.004912 0.006344 . 0.008116 0-010284 0.012919 0.016092 0.019888 0.024384 0.029700 0.035932 0.037286
0.08629 0.08442 0.08262 0.08088 0.07917 0.07751 0.07586 0.07422 0.07257 0.07090 0.06919 0.06737 0.06548 0.06346 0.06129 0.05891 0.05631 0.05342 0.05022 0.04666 0.04268 0.03616 0.03729
0.02078 0.02031 0.01987 0.01946 0.01908 0.01872 0.01838 0.01805 .0.01775 0.01747 0.01721 0.01696 0.01675 0.01657 0.01642 0.01630 0.01624 0.01621 0.01624 0.01633 0.01649 0.01672 0.01818
48.12 49.24 50.33 51.39 52.41 53.42 54.41 55.40 56.34 57.24 58.11 58.96 59.70 60.35 60.91 61.35 61.58 61.69 61.58 61.24 60.64 59.81 55.01
0.2408 0.2406 0.2405 0.2406 0.2410 0.2415 0.2423 0.2432 0.2446 0.2464 0.2487 0.2517 0.2558 0.2611 0.2679 0.2767 0.2884 0.303* 0.3234 0.3500 . 0.3864 0.4624 0.4875
Compiled by W. H. Severns, based on the instantaneous specific heats of air.
Table 3. Specific Heats of Dry Air* Constant Barometric Pressure of 29.921 In. of Hg
Temperature Deg F
Instantaneous or True
Specific Heat
Temperature Range Deg F
Mean Specific
Heat
-301.0 -108.4
32.0 , 212.6
392.0 752.0 1112.0
0.2520 0.2430 0.2399 0.2403 0.2413 0.2430 0.2470
32 to 212 32 to 392 32 to 752 32 to 1112
0.-2401 0.2411 0.2420 0.243d
Complied by W. H. Sevems, based on data given in the International Critical Tables. 5