Document MM80DGLQb1Kqxo81Bown1vzRx
February 23, 1982
POLY 'A' PERSONNEL
cc: Medical Department S. Biggs A. 3. Seidule
C. E. Halphen E. Whitman
*
ENVIRONMENTAL HEALTH SURVEY REPORT - 1981
< This survey will include the results of data obtained on Isopar C, Isopar-M, noise and 5102 (Superfloss) within the Poly "A" block. Appendices will be used to show the TWA (time weighted averages) exposure, according to job classification, in each of these areas.
Due to the consistently very low concentrations of all other chemicals and polyethylene dust in the Poly "A" plant, they have been deleted from our survey.
I. Noise Level Exposure Two methods were used to analyze for noise exposure:
A. B&K noise level meter. This instrument is used to pinpoint the source of noise.
B. Audio dosimeter. This instrument gathers a composite sample of noise to which an individual is exposed.
1. B&K noise level meter (see attached survey of "Evaluation of Noise Exposure", Appendix A.). The following are the areas above 85 dB(A):
a. Building 804 (Extrusion Building) outside areas along the west, north and east walls are above 85 dB(A). Outside the west and north walls, this noise is caused by transfer and recycling of pellets and transfer blowers. Outside the_ east wall, the noise is produced by primary extruders and transfer blowers. Noise inside of Building 804 is due to primary and secondary extruders, transferring of pellets and spin dryers.
b. Building 803 (Secondary Compressor Building). The main source of noise in this building is C-101 thru C-109 - secondary compressor. Another noise source is the train 5 pellet transfer line outside Building 803 on the northeast side.
085069 CONFTDFNTTAl
Envlrbnmental Health Survey
-2
Fehruary 23, 1982
I. Noise`Level Exposure (Continued)
c. Building 802 (Primary Compressor Building), Each primary compressor contributes to the high noise level In this building.
d. Building 809 (Train 5) inside Building 809, the noise is caused by secondary compressors (C-501 and C-502), primary extruder, transfer blowers, transfer of pellets and spin dryer. Outside, the only high noise area is around AC-5 (Air 'Compressor).
02.
Audio Dosimeter - There were three classifications with individual (TWA) dosimeter readings above 85 dB(A). When questioned after sampling, none of these employees could remember anything that would have caused the high readings (See attached survey of "Noise Survey by Dosimeter",^^po|iix-B).
Exposure to SiO? (Superfloss). Operators involved in mixing
S102 wear Bust masks, and are only^exposed to the SiOj for approximately 15-20 minutes per mix or 30 minutes per day. The exposure to S102 was less than 0,01 mg/m^ on respirable
and non respirable dust.
III.
Chemical Exposure. There were only two chemicals surveyed in the Poly "A" block in 1981. They were Isopar-C and Isopar-M. These are listed in Appendix-C.
The remainder of the chemicals present in the Poly "A" block were not considered to be in concentrations high enough to require monitoring.
Donnie Lee Poly "A" Plant Building 807 Plaquemine
Attachments (5)
ltb
DO 8So?o
cNFjD
APPENDIX B Noise Survey Ry Dosimeter - 85 riB(A) 1981
DOR CLASSIFICATION Shift Supervisor
H2 Boarriman (Control Room) H5 Sr. Compressor Operator (O.S.)
Hi Compressor Operator (S.O.T.)
tf1 Compressor Operator (S.O.T.)
Hk Extrusion Operator (S.O.T.)
II2 Lab Transfer Operator (S.O.T.) #3 Extrusion Operator (O.T.)
Day Operations Supervisor Day Operations
A/
Catalyst Mixers ^ '
O.C. Supervisor Sr. Asst. Chemist Training Supervisor Engineer
SURVEY DATE
8-07-81 8-28-81
8-06-81 ' 8-25-81
8-13-81 9-08-81 9-14-81
8-13-81 9-02-81 9-21-81
8-14-81 9-01-81 9-04-81
8-11-81 9-04-81 9-08-81
8-11-81 8-31-81
8-07-81 8-31-81 9-15-81
8-25-81
8-19-81 8-26-81 9-01-81
8-14-81 8-26-81
8-05-81
9-04-81
8-21-81
8-12-81 8-24-81
EXPOSURE PERIOD (HRS)
8 6.5
7 6.5
6 7 7
6 6.5 7
7 7 7
7 7 7
7 7
6 7 7.5
6.5
7.5 7 7
7 7
7
8
7
7 7
% TWA
m\
66 39 48
2.2 23
38 86 49
18 57 37
43 60 76
23 47 88
10 12 13 14
34 '0 63
25
16 20
19 29 33 J 17
28 31^\ 44 51^/
11
13 13
19 22
33 11
DO 005071 CONFIDENTIAL
V
Noise Survey By Dosimeter - 85 riB(A) 1981 (continued...)
non CLASSIFICATION
Plant Superintendent Material Controller Secretary electrician Instrument
Equip. Supervisor (Mech)
Equip. Supervisor (Ext) Production Supervisor Millwright
Pipefitter
Laborer
SURVEY DATE
6-27-81
8-12-81
8-19-81 '
8-20-81
8-17-81 8-17-81 9-02-81
8-21-81 9-03-81
8-27-81
8-24-81
8-18-81 8-28-81
R-18-81 8-20-81
8-06-81
EXPOSURE PERIOD,(HRS)
7
7.5
8
8
7 7 7
7 7
7
7
7.5 6.5
7.5 8
7
% TWA
0
15
0*
9
33 107
6
84 24
54
3
l1? 25
20 26
3
TWA 0
16 0 9
7 96 27 62
3 82 31 21 26
4
0&5072 CONFrOFNTTA!
EVALUATION OF NOISE EXPOSURES POLYETHYLENE 'A' APPENDIX - A
CHART #
LOCATION
dB(A)
1980
1981
CHART fl
LOCATION
dB(A)
I960
1981
1 POLY 'O' FAB LAB
73 70
2 PARTS WAREHOUSE (N.ENO)
66 71
3 PARTS WAREHOUSE (S.END)
70 72
4 MAINT. SHOP (N.ENO)
72 71
5 MAINT. SHOP (S.END)
71 73
EXTRUSION BLOG.(804)
6 BAC 8A 4 B
84 87
7 BAC 2A 4 B
78(DOWN) 95
8 MAKE HOPPERS 101A -106B
87 95
9 BAC 3A 4 B
92 (DOWN) 100
10 BAC 7A 4 B
91 94
11 HMB 107-114
89 92
12 BAC 7C 4 D
89 99
13 X104
92 90
14 X103
92 90
15 X102
93. 89
16 X101
91 90
17 PRIMARY TRANSFER LINES (S.ENO) 100
98
18 PRIMARY TRANSFER LINES (N.ENO)
95
95
19 X121 (N.ENO) RUNNING
(DOWN)
88
20 X120 (N.END) DOWN
86 84
21 XI20 (S.ENO) DOWN
86 83
22 X121 (S.ENO) RUNNING
(DOWN)
91
23 LAB TRANSFER ROOM
67 67
24 AISLEWAY-B804 (N.ENO)
84 83
25 AISLEWAY-B804 (MIDDLE)
89 87
26 AISLEWAY-B804 (S.ENO)
90 89
27 XO 101
92 90
28 XO 102
93 86
29 XD 103
92 90
30 XO 104
92 94
31 XD 120
(DOWN)
32 XD 121
86
33 0 212
80
34 ADDITIVE MIX DRUM AREA
83
35 BAC 1A 4 B
93
36 BETWEEN S-111 4 S-112
90
37 BETWEEN S-113 4 S-114
91
38 C-202 (E.END)
88
39 BAC 1 C* D 4 E
90
40 ROADWAY BETWEEN B803 4 804
81
SECONDARY COMPRESSOR BLDG..
41 C 109 42 C 108
43 C 107 44 C 10'6 45 c 105 46 C 104 47 C 103 48 c 102
j s
91
tSm V 92 Z/AWi * 91
u (1ft tfH .90
f/sr. / 91
^ AX
91
t\ V JifJs ?,/ / 90
'Wy
91
49 C 101
91
50 TRAIN I
Y
92
51 TRAIN II CAT PUMPS *
92
52 TRAIN III CAT PUMPS
92
53 TRAIN IV CAT PIMPS
93
54 TELOMER PUMPS TRAIN IV
83
55 D-146C (WALKWAY)
87
56 OLD E-199B AREA (WALKWAY)
85
57 TRAIN IV CATLAYST MIX AREA
82
58 D-146A (WALKWAY)
85
59 TELOMER PIMPS TRAINS I,II, III 81
60 CATALYST MIX AREA (S.END)
80-
61 CONTROL ROOM
62
62 CHANGE ROOM
# 65
86 91 80 80 90 90 92 90 91 78
92 92 92 91 90(DOWN 90(DOWN 90(DOWN 90 90 92 91 * 94 1 95 85 86 66 81 85 84 80 63 52
DO 0 8 5 0 7 3 C O N F ID E N T IA L
DO 0 8 5 0 7 4 CO NFIDENTIAL
r EVALUATION OF NOISE EXPOSURES
POLYETHYLENE 'A' APPENDIX - A (PACE 2)
CHART 9
LOCATION
dB(A>
1980
1981
PRIMARY COMPRESSOR BLDG (B802)
63 WALKWAY (NW END) 64 WALKWAY {SW END) 65 C-441 66 C-241 67 C-231
68 C-331 69 C-341 70 C-201 71 C-200 72 C-342 73 C--141 74 C-142 75 C-131 76 AC-1 THR 4 77 COALESCER
88 86 93 93 95 96 95 95 95 93. 93 94 96 , 87 88
TRAIN 5 . 78 AC-5
89
79 CATALYST MIX AREA
TRAIN V DOWN
80 WALKWAY BY D-215 81 WALKWAY BY ER-501
INVENTORY CONTROL
82 B-809 (NE END)
83 B-809 <SE END)
84 C-501
85 C-502 86 TRAIN V CATALYST PUMPS
87 X-505
88` BAC 51 A lr B
09 C-541/531
84 84 90 90 (DOWN/. 90(DOWtf; 94 92 92 94 93 91 90 89 83 82
95 78 82 82 91 90 95 92 91 94 101 87
f
t
CHEMICALS SURVEYCD APPCNDIX - C
CO
o
1. ISOPAR - C
DATE 10-14-81 10-22-81 11-03-81 10-21-81 10-27-81 11-09-81 10-19-81 10-22-81
10-15-81 10-26-81 11-10-81
00B CLASSIFICATION
EXPOSURE PERIOD (MINIMUM)
O.S. COMPRESSOR
360
O.S. COMPRESSOR
360
O.S. COMPRESSOR
. 360
O.S. COMPRESSOR (TR. V)
360
S.O.T. COMPRESSOR (TR. V) 420
S.O.T. COMPRESSOR (TR. V) 420
CATALYST MIXER
360
CATALYST MIXER
360
CATALYST MIXER
420
MILLWRIGHT
360
MILLWRIGHT
450
MILLWRIGHT
300
PPM* (TWA)
0.1 0.4 1.1 0.8 0.3 0.4 1.0 0.8 1.1 2.1 2.4 0.7
2. ISOPAR - M
10-15-81 10-26-81 11-10-81
MILLWRIGHT MILLWRIGHT MILLWRIGHT
360 450 300
20.2 7.4 0.6
DGA/ltb 2-23-82