Document MJyj556opbXXrBGQJ4OLN9yZa

Analytical Chemiscrv Special Study 70-17 Job No. 1348046 determination of polychlorinated biphenyl residues in rats ________________ from 30 DAY aroclor feeding studies introduction One of the more significant objectives of the Aroclor - Environment program has been to develop a more complete picture of what occurs to Aroclor products once they are released to the ecosystem. The importance of this information is two fold, first it can be used to guide the development of a more "degradable" Aroclor product and secondly, the general methods developed to study the current Aroclor products can be used to determine the degree of control that must be exercised over the replacement products to avoid similar problems with these materials in the future. As a part of achieving this overall objective. Industrial Bio-Test Laboratories was requested to carry out a 30 day tissue collection study in albino rats with Aroclor 1242, Aroclor 1254 and Aroclor 1260. This report deals with the subsequent analysis of these tissues for residual PCB's. The details of tissue collection study can be found in the Industrial Bio-Test report, IBT No. B7009. A copy of this report is attached. SUMMARY The results of this study demonstrate that the residual PCB levels in all tissues decreased significantly as the degree of chlorination and the dietary exposure level of the material fed decreased. Additionally, it vas observed that the amount of isomeric alteration Increased as the degree of chlorination decreased resulting in the fact that the major PCB isomers retained by the rats fed Aroclor 1242 were those predominantly present in Aroclor 1254 and Aroclor 1260. There were no significant differences in the type of isomeric alteration from tissue to tissue or between sexes. RESULTS The experlmentel data supporting the conclusions are shown in Tables I - III, and in Figures I - VIII. DISCUSSION All tissue samples were analysed as outlined in Analytical Chemistry Method No. 70-1 and the PCB levels estimated using the Aroclor fed as the standard. Upon completion of the electron capture (EC) work all tissue extracts, for each Aroclor fed, were combined and con centrated. The concentrates were then further purified via liquid chromatography on alumina and subjected to high resolution gas OSW 005854 STLCOPCB4000490 Special Study 70-17 . Page 2 chromatography on a support coated open tubular (S.C.O.T.') column in an attempt to identify ai many of the remaining isomers and homologs as possible. The EC chromatograms (Figuras I-111) included in this report are representative of those obtained for each tissue (muscle, liver, kidney, and fat) and each Aroclor. For Aroclor 1242 the dominant PCB homologs retained are peak numbers, 8(tri); 10, 13, 14(tetra); 15, 16(penta); 20, 22(hexa); and 26(hepta). With Aroclor 1254 they are, lS(penta); 20, 22(hexa); and 26(hepta) and with Aroclor 1260 they are, 20, 22(hexa); 26, 27(hepta); and 28, 29, 30(octa). The fact that peaks 10, 13, 14, 15 and 16 are present in Aroclor 1242 extracts but not as dominant in Aroclor 1254 and Aroclor 1260 extracts seems to indicate that if the Aroclor 1242 dietary exposure level were reduced sufficiently these homologs would also be metabolized and/or excreted as they were with Aroclor 1254 and 1260. The very refractory homologs appear to begin with peak 020 in the penta-hexachlorobipheny1 region. EC chromatograms of fractionated Aroclor 1130 and MCS 1016 (Figure IV) are included for comparison purposes. From these, it can be readily seen that these materials are a marked improvement over Aroclor 1242 in that they contain no observable amounts of the homologs that build up. The S.C.O.T. column chromatograms (Figures VI-V1II) of the concen trated extracts are even more instructive in that the greater separation power of the column allows the identification of some of the PCB isomers that are not retsined. For example, only traces of the following biphenyl isomers, dominantly present in the material fed remain: 2-ehloro; 3-chloro; 4-chloro; 2,6dichloro; 2,4-diehloro; 2,5-dichloro; 2,3'-dichloro; 2,4'-dich loro ; 2,5,2'-trlchloro; 3,3'-dichloro; 3,4-dichloro; 3,4'-dichloro; 4,4'-dichloro; 2,3,2'-trichloro; 3,4,2 *-trichloro and 2,3,4'trlchloro . The S.C.O.T. column chromatograms (Figure IX) of the proposed substitutes are again included for comparison purposes. db Monsanto Company Organic Chemicals Company Applied Sciences Section St. Louis, Missouri 9/70 - W. J. Litschgi, B. J. Westenberger, E. S. Tucker DSW 005855 STLCOPCB4000491 TABLE I ESTIMATED PCB CONTEXT OF RAT TISSUES Test Dietary Coapound Sex Level AROCLOR 1242 M F 300 300 M 1000 F 1000 FAT ppa Found Wet Wt Lipid Ut - 276 377 412 - 395 816 722 AROCLOR 1254 M F 300 300 M 1000 F 1000 695 660 4660 3430 1094 1289 7208 7544 AROCLOR 1260 M F 300 300 2130* 2035 3061 3430 M 1000 9190 13715 F 1000 11970 19088 KIDNEY ppa Found Wet Wt Lipid Wt 1.40 2.30 5.00 2.30 12.4 28.1 276 146 7.90 12.9 46.6 156 655 1895 3325 12972 28.8 16.0 72 . 5 91.0 2056 2671 5181 7579 LIVER ppa Found Wet Wt Lipid Wt 2.70 4.60 10.5 17.4 60.6 220 753 793 56.9 53.7 176 227 2370 3358 5318 6678 126 125 200 206 3808 6226 6263 10300 MUSCLE ppm Fo und Wet Wt Lipid W t 5.00 12.2 16.9 29.0 37.3 58.3 736 855 55.8 36.0 271 167 1396 1274 7735 6202 81.6 136 266 555 24 70 4849 8879 24111 STLCOPCB4000492 C3 to O o VJ1 CD U1 O' TABLE II ELECTRON CAPTURE GAS CHROMATOGRAMS Chromatoer-phlc Conditions Instrument: Hewlett-Packard Model 402 Type Detector: Nl^ Electron Capture Column: 6' X 4 mm glass U, 4X XE-60 on 80/100 Mesh Chroaosorb W, HP Column Temperature: 200*C Detector Temperature: 300*C Injection Port Temperature: 220*C Carrier - He, 60 ml/min Purge Ar/CH4 (g/1) 120 ml/min Electron Capture Peak 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Dominant Hoaolog as Identified by GC/MS Aroclor Aroclor Aroclor 1242 1254 1260 1 1 2 2 3 3 3 3 3 4 444 4 44 44 55 55 5- 56 66 66 66 66 66 7 7 7 7 7 8 8 8 8 DSW 005857 STLCOPCB4000493 STLCOPCB4000494 DSW 005659 STLCOPCB4000495 STLCOPCB4000496 4 &+0C4.0* 005861 STLCOPCB4000497 TABLE III FFAP S.C.O.T. COLUMN CHROMATOGRAMS Chromatographic Conditions Instrument: Perkin-Elmer Model 800 equipped with a 30/1 sample Inlet splitter Type Detector: Flame Ionization Column: 100' X .02" FFAP S.C.O.T. Column Column Temperature: 23 5 #C Detector Temperature: 280*C Injection Port Temperature: 340*C Carrier Gas - Helium @ 15# FFAP S.C.O.T. Column Peak No. Compound As Identified by Retention Time Number of Chlorines 1 Biphenyl 0 22 l 33 1 44 i , '5 2,6 6 22 2 2 7 2,4 2 8 2,5 2 9 2,3' 2 10 2,4' 2 11-3 12 2,5,2' 3 13 3,3' 2 14 3,4 2 15 3,4' 2 16-3 17 4,4' 2 18 2,3,2' 3 19 2,5,4' 3 20-3 21 3,4,2' 3 22-3 23- 26 - 3 27 2,3,4' 3 28-37 - 4 38 3,4,4' 3 39-42 - 4 43-49 - 5 DSW 005862 STLCOPCB4000498 DSW 005863 STLCOPCB4000499 STLCOPCB4000500 DSW 005865 STLCOPCB4000501 STLCOPCB4000502