Document MJyj556opbXXrBGQJ4OLN9yZa
Analytical Chemiscrv Special Study 70-17 Job No. 1348046
determination of polychlorinated biphenyl residues in rats
________________ from 30 DAY aroclor feeding studies
introduction
One of the more significant objectives of the Aroclor - Environment program has been to develop a more complete picture of what occurs to Aroclor products once they are released to the ecosystem. The importance of this information is two fold, first it can be used to guide the development of a more "degradable" Aroclor product and secondly, the general methods developed to study the current Aroclor products can be used to determine the degree of control that must be exercised over the replacement products to avoid similar problems with these materials in the future.
As a part of achieving this overall objective. Industrial Bio-Test Laboratories was requested to carry out a 30 day tissue collection study in albino rats with Aroclor 1242, Aroclor 1254 and Aroclor 1260. This report deals with the subsequent analysis of these tissues for residual PCB's.
The details of tissue collection study can be found in the Industrial Bio-Test report, IBT No. B7009. A copy of this report is attached.
SUMMARY
The results of this study demonstrate that the residual PCB levels in all tissues decreased significantly as the degree of chlorination and the dietary exposure level of the material fed decreased.
Additionally, it vas observed that the amount of isomeric alteration Increased as the degree of chlorination decreased resulting in the fact that the major PCB isomers retained by the rats fed Aroclor 1242 were those predominantly present in Aroclor 1254 and Aroclor 1260. There were no significant differences in the type of isomeric alteration from tissue to tissue or between sexes.
RESULTS
The experlmentel data supporting the conclusions are shown in Tables I - III, and in Figures I - VIII.
DISCUSSION
All tissue samples were analysed as outlined in Analytical Chemistry Method No. 70-1 and the PCB levels estimated using the Aroclor fed as the standard. Upon completion of the electron capture (EC) work all tissue extracts, for each Aroclor fed, were combined and con centrated. The concentrates were then further purified via liquid chromatography on alumina and subjected to high resolution gas
OSW 005854
STLCOPCB4000490
Special Study 70-17 . Page 2
chromatography on a support coated open tubular (S.C.O.T.') column in an attempt to identify ai many of the remaining isomers and homologs as possible.
The EC chromatograms (Figuras I-111) included in this report are representative of those obtained for each tissue (muscle, liver, kidney, and fat) and each Aroclor. For Aroclor 1242 the dominant PCB homologs retained are peak numbers, 8(tri); 10, 13, 14(tetra); 15, 16(penta); 20, 22(hexa); and 26(hepta). With Aroclor 1254 they are, lS(penta); 20, 22(hexa); and 26(hepta) and with Aroclor 1260 they are, 20, 22(hexa); 26, 27(hepta); and 28, 29, 30(octa). The fact that peaks 10, 13, 14, 15 and 16 are present in Aroclor 1242 extracts but not as dominant in Aroclor 1254 and Aroclor 1260 extracts seems to indicate that if the Aroclor 1242 dietary exposure level were reduced sufficiently these homologs would also be metabolized and/or excreted as they were with Aroclor 1254 and 1260. The very refractory homologs appear to begin with peak 020 in the penta-hexachlorobipheny1 region.
EC chromatograms of fractionated Aroclor 1130 and MCS 1016 (Figure IV) are included for comparison purposes. From these, it can be readily seen that these materials are a marked improvement over Aroclor 1242 in that they contain no observable amounts of the homologs that build up.
The S.C.O.T. column chromatograms (Figures VI-V1II) of the concen trated extracts are even more instructive in that the greater separation power of the column allows the identification of some of the PCB isomers that are not retsined. For example, only traces of the following biphenyl isomers, dominantly present in the material fed remain: 2-ehloro; 3-chloro; 4-chloro; 2,6dichloro; 2,4-diehloro; 2,5-dichloro; 2,3'-dichloro; 2,4'-dich loro ; 2,5,2'-trlchloro; 3,3'-dichloro; 3,4-dichloro; 3,4'-dichloro; 4,4'-dichloro; 2,3,2'-trichloro; 3,4,2 *-trichloro and 2,3,4'trlchloro .
The S.C.O.T. column chromatograms (Figure IX) of the proposed substitutes are again included for comparison purposes.
db
Monsanto Company Organic Chemicals Company Applied Sciences Section St. Louis, Missouri
9/70 - W. J. Litschgi, B. J. Westenberger, E. S. Tucker
DSW 005855
STLCOPCB4000491
TABLE I ESTIMATED PCB CONTEXT OF RAT TISSUES
Test
Dietary
Coapound Sex Level
AROCLOR 1242
M F
300 300
M 1000
F 1000
FAT ppa Found Wet Wt Lipid Ut
-
276 377 412
-
395 816 722
AROCLOR 1254
M F
300 300
M 1000
F 1000
695 660 4660 3430
1094 1289 7208 7544
AROCLOR 1260
M F
300 300
2130* 2035
3061 3430
M 1000
9190
13715
F 1000 11970 19088
KIDNEY ppa Found Wet Wt Lipid Wt
1.40 2.30 5.00 2.30
12.4 28.1 276 146
7.90 12.9 46.6
156
655 1895 3325 12972
28.8 16.0 72 . 5 91.0
2056 2671 5181 7579
LIVER ppa Found Wet Wt Lipid Wt
2.70 4.60 10.5 17.4
60.6 220 753 793
56.9 53.7
176 227
2370 3358 5318 6678
126 125 200 206
3808 6226 6263 10300
MUSCLE ppm Fo und Wet Wt Lipid W t
5.00 12.2 16.9 29.0
37.3 58.3 736 855
55.8 36.0
271 167
1396 1274 7735 6202
81.6 136 266 555
24 70 4849 8879 24111
STLCOPCB4000492
C3
to
O
o
VJ1 CD
U1 O'
TABLE II ELECTRON CAPTURE GAS CHROMATOGRAMS
Chromatoer-phlc Conditions
Instrument: Hewlett-Packard Model 402
Type Detector: Nl^ Electron Capture
Column: 6' X 4 mm glass U, 4X XE-60 on 80/100 Mesh Chroaosorb W, HP
Column Temperature: 200*C Detector Temperature: 300*C Injection Port Temperature: 220*C
Carrier - He, 60 ml/min
Purge
Ar/CH4 (g/1) 120 ml/min
Electron Capture Peak
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Dominant Hoaolog as Identified by GC/MS
Aroclor
Aroclor
Aroclor
1242
1254
1260
1 1 2 2
3
3 3
3
3 4 444 4 44 44 55
55 5-
56 66 66 66 66 66
7 7 7
7 7 8 8 8 8
DSW 005857
STLCOPCB4000493
STLCOPCB4000494
DSW 005659
STLCOPCB4000495
STLCOPCB4000496
4 &+0C4.0*
005861
STLCOPCB4000497
TABLE III FFAP S.C.O.T. COLUMN CHROMATOGRAMS
Chromatographic Conditions
Instrument: Perkin-Elmer Model 800 equipped with a 30/1 sample Inlet splitter
Type Detector: Flame Ionization Column: 100' X .02" FFAP S.C.O.T. Column Column Temperature: 23 5 #C Detector Temperature: 280*C Injection Port Temperature: 340*C Carrier Gas - Helium @ 15#
FFAP S.C.O.T. Column Peak No.
Compound As Identified
by Retention Time
Number of Chlorines
1 Biphenyl
0
22
l
33
1
44
i
, '5 2,6
6 22
2 2
7 2,4
2
8 2,5
2
9 2,3'
2
10 2,4'
2
11-3
12 2,5,2' 3
13 3,3'
2
14 3,4
2
15 3,4'
2
16-3
17 4,4'
2
18 2,3,2' 3
19 2,5,4' 3
20-3
21 3,4,2' 3
22-3
23-
26 -
3
27 2,3,4' 3
28-37
-
4
38 3,4,4' 3
39-42
-
4
43-49
-
5
DSW 005862
STLCOPCB4000498
DSW 005863
STLCOPCB4000499
STLCOPCB4000500
DSW 005865
STLCOPCB4000501
STLCOPCB4000502