Document MJxJNNN7KDbn2ez86JOpdOX27

By Walter C. McCrone and Jan M. Stewart ; v may 1968, Dr. Irving J. Selikoff of the Mount Sinai Hos- ` pital in New York established his position as the Rachel Carson of the industrial hygiene world. A series of New Yorker articles at that time was based largely on Dr. SeiikofFs experiences in the study of asbestosis, lung and stomach cancer, mesothelioma, and other causes of death related to ex posure to asbestos. His careful analyses of mortality of industrial workers in known asbestos fiber contaminated areas are convinc ing arguments that asbestos is one of the most deadly industrial hygiene hazards. The reputation of large indus trial concerns has not always been good when faced with evidence that their plant environments may be contributing to worker disabil ities, if not death. However, large ly through Dr. Selikoffs effort Dr. McCrone is Scientific Adviser and Mr. Stewart is Manager. Electron Optics Croup. McCrone Associates. Inc. followed up by the FDA, Depart ment of Labor, and other inter ested parties, most responsible companies are now doing their best to minimize, if not eliminate, asbestos as a health hazard. The microscopist has an im portant role in this program to control asbestos as a contaminant in the air we breathe, the fluids we drink, and the food we eat. He must be able to identify asbestos fibers and quantify their size and number. There are problems be cause there are other fibrous sub stances confusingly similar to as bestos. and there are several dif ferent types of asbestos (Table /), differing in optical properties and composition and possibly in the degree of their hazard to humans. Analytical methods must be sensitive enough for the identifica tion of single fibers. Of course, only a microscope aftd a trained microscopist can do this. There are methods, e.g.. x-ray diffrac tion and DTA. that identify min ute percentages of asbestos in Chrysotila fiber bundle. Tabid 1 Composition Strptntin* Asbestos Amphiboles CHRYSOTILE ACTINOLITE TREMOLITE ANTHOPHYLLITE 3Mg02S)02* 2CaO*4MgO* 2CaO*5MgO* 2HjO Fe0*8Si02*H20 8SiOj*HjO 7MgO*8SIOj HjO Specific gravity Crystal system Refractive indices 2.36-2.5 monoclinic 1.49-1.57 3.03-3.5 monoclinic 1.62-1.68 2.9-32 monoclinic 1.60-1.65 2.85-3.5 orthorhombic 1.60-1.66 DOW 05603 AMOSITE 5*5FeO 1*5MgO 8SiO]*HjO 2.6-3.0 monoclinic 1.66-1.70 CROCIDOUTE NajO^FejOj* 3FeO*8SiOj HjO 3.0-3.45 monoclinic 1.69-1.71 AMERICAN LABORATORY : 13 UST0 607U ASBESTOS continued / Table 2 Asbestos type Chrysotile Anthophyllite Amosite Crocidolite Dispersion staining colors for asbestos Refractive index liquid Dispersion staining color Parallel Perpendicular 1.560 1.610 1.670 1.700 light blue blue-green red magenta magenta magenta golden yellow golden yellow blue magenta 'mall samples, but only the microscopist can hope to identify inJi'idual fibers. Fortunately, the crystallographic properties of the different types of asbestos are suf ficiently distinct to enable certain identification. If the fibers are thicker than about 0.5 fim, light microscopy suffices; smaller fibers require the electron microscope. Identification of the larger fi bers by light microscopy is based on refractive index measurement using a polarizing microscope. The easiest way to apply refrac tive index measurement to asbes tos fiber identification is by use of dispersion staining, an optical staining procedure. This is based on annular or central screening of the objective aperture in common with specific refractive index me dia. such as the Cargille liquids. Under these conditions each type of asbestos shows two character istic dispersion staining colors, one for the light vibration direc tion parallel, and another perpen dicular. to the fiber length (but only in one particular refractive OOUJ 05604 index liquid-!. Table 2 shows the colors obtained with several kinds of asbestos when mounted in ap propriate Careille refractive index liquids. Different colors or no colors are observed if other than the specified liquids are used for each particular asbestos sample. Finding small percentages of very fine asbestos fibers requires care ful application of the method. In particular, intense Kohler illumi nation with carefully centered substage and objective apertures is essential. A careful microscopist should, however, be able to detect 0.01^ of >0.5 /amthick fibers by this technique. Light microscopy is ideal for rapid identification of asbestos in most powdered samples: dust, mortar, insulation or wallboard, mineral samples such as talc. etc. When the presence of asbestos in a liquid medium, such as a water supply, soft drink, beer, or pa renteral solution is suspected, one must assume most of the fibers, if not all, will be too fine to ob serve by light microscopy. One turns, then, to the transmission electron microscope (Figure 1). The transmission electron micro scope (TEM) is superior to the scanning electron microscope for two reasons. Smaller fibers can be observed and identified by TEM. and selected area electron diffraction (SAED) is more de pendable for identification of as bestos than the elemental analysis capability of the SEM. Figure 1 Model 200KV transmission electron microscope. J > f 9L09L*i0iS EXTENDING MAN'S VISION IN THE SEAS The seas are our new frontier. From an underwater Nikonos Scientists are exploring the camera to the compact Model vast resources of the oceans, H microscope, we are produc not only for links to our origins, ing instruments used by our but for new sources of food. scientist/conservationists to Many scientists believe that insure the continuation of the our beleagured planet cannot species, man. forever support the popula Producing the finest instru tion explosion. ments available for science The warning voices of these men are at fast being heard. and industry is a constant challenge. Mankind is slowly awakening to the frightenfng realization that even our seas cannot withstand the absorption of Wherever essential research is being conducted: on land, beneath the seas, or in space-- we are meeting that challenge. man's waste without dire Extending your vision is our consequences. main concern. Nikon is in the forefront of undersea research technology. The finest optics in the world. Nikon Instrument Division. Ehrenreieh Photo-Opticai Industries. ------- 'g:! Sn*wart Ave . '.i.irden t'':y. \ V. CMikon) Tei. 1= . In Canada. Ansriouhoto Ltd.. Ontario Nikon SMZ Stereo Zoom Microscope Total magnification ranve. 4X to |J0X. Provides S time zoom ranee without chance m focus. Excep tional wide ranee of accessories. Reader Card = 107 Nikon F.pMHuminator Fits an> standard Nikon microscope. Detuned for observation of opaque specimens. Provides colli mated on-jxis illumination with field and aperture control. Dark field reflected lieht systems available. Reader Card* 10 DOW 05605 Nikon ki Compact Versatile laboratory microscope with built-in transformer, continuously variable licht mtensitv c'Mfol. and inbase volt meter Features brilliant Koehler (vpc illumination and tull ranee Nikon .itcessonev iwadcr v. aid =109 A. - i 'LAl- l',-' ASr r-J&Ta--*- r- -. *:*> iv .',^*.*4- v . * 4* *"v 4* -<:- ^, ***. ** . - *,**:** 3* E'JV^r.v^. * .J V fausch A Comb's nsw Bafplan'Mi- i jfeJnfl ^ifs research quality Instrument jfjgbee. Interchanging modules, attaching 'iKFquIck arid uncomplicated; focusing, so pl^ ypur most vital investigations become "a'fatiguing, most rewarding. . . _ j'uiar system of integrated components is i a stand that features an axctiislve, suspended ifm. iie as many accessories on the stand as you '<v as part of the vibration-free inner arm, ^ita^jdrift-free, accurate focus. ~ ^ gls^controlled by concentric, comfortafc Itlbned knobs. Fine focus is graduated in single mi* . you to dissect visually each layer of the <r"* ^' spedfnen.wlth ease. A complete revolution of the focus ing khob'moves the stage 100 microns. With the transformer housed in the base and with front push-button controls all circuitry is enclosed. The line cord plugs into the base at the rear while accessory cords plug into the upper back 'area of the stand. Hazardous, bothersome dan gling wires are eliminated. Notably improving performance, the patented Vslide holder on the mechanical stage is spring - mounted downwards to hold the slide in con stant contact with the stage surface, lepleces for 2, 3, 4 or 5 objectives are reversible, interchangeable, parcentered and accurately position ob]egtiv*wlth a ball detent '; Accessories for visual and photographic use are all de signed to be compatible within the Balplan system. .To top it off-There's a choice of interchangeable heads, including a dual-viewing adapter with illuminated pointer. That in brief, is the architecture of Balplan, the oneo^a-klnd new concept in a competitively priced micro scope with models for clinical, research and educational applications. * ' BAJSCH & tomb Trtfontmt. DOW 05fcOfe SCIENTIFIC OPTICAL PRODUCTS DIVISION. 38804 BAUSCH STREET. ROCHESTER. N Y. 14602 \ STOS zontmued Figure 2 Chrysotile fibers filtered from a water supply, 30 000X. Figure 3 Selected area electron diffraction pattern tor a single chrysotile fiber. \ sample of water of known ..'mme is filtered through the fine-: membrane filter. A section of filter approximately 2-3 mm2 is then placed particle side down on a previously carbon-coated elec tron microscope grid, and the membrane filter is dissolved using acetone in a Soxhlet extractor. The sample grids are examined in our laboratory with a JEM 200 electron microscope, using an ac celerating voltage of 150 kv at a magnification of 17.000X on the M? range of the instrument. This magnification is chosen to focus the intermediate lens aperture in line with the specimen plane: thus, a SAED pattern of the fiber is ob tained with no other adjustments to the microscope. In this way it is possible to spot check the dif fraction pattern of individual fi bers rapidly (Figures 2 and 3). The total number of asbestos fibers is related to a definite area of the filter, and hence a definite ''iume of sample, by counting fi bers over a known number of 7EM end squares t having known areas). The length and width of each asbestos fiber is recorded. Interpolation from the screen scribed at half-centimeter intervals allows an accuracy of measure ment on the screen of approxi mately + 0.05 cm. or about +34 nm. Measurements of the indi vidual fibers are read into a tape recorder: this permits the operator to devote full attention to the screen, precludes duplicate count ing of single fibers, prevents miss ing fibers, and maintains the op erator's dark accommodation. The recorded data are trans cribed onto punch-tape and com puter processed to give listings of the length, width, and aspect ratio of the fibers, together with a com puted mass of each fiber calcu lated on the basis of density D and dimensions L and W (D \ L X W*). Density values for the different asbestos types are given in Table 1. Also presented in the computer print-out is the num ber of fibers per liter of water, the size distribution of the fibers based on length and width, and the distribution of fibers by aspect ratio. The program automatically assigns the longest dimension to the fiber length and excludes all fibers with an aspect ratio below three. This procedure, designed by Ian Stewart of our laboratory, has been applied with excellent suc cess to a number of water samples containing large numbers of amphiboles per liter but very low weight percentages. Most of these samples show no asbestos fibers by light microscopy. It is there fore important to specify the method of analysis when stating analytical results. The same sam ple of talc could be analyzed by different methods with very dif ferent results, e.g.: 1. X-ray diffraction shows no chrysotile or amphiboles. 2. A phase-contrast method (similar to the NIOSH procedure to determine the number of fibers per milliliter of air) shows 1500 fibers greater than 5miti mJ of sample. 3. The scanning electron mi croscope with energx dispersive x-ray analyzer shows about 10* (.O'JL'lOlS 23 N O i/l o 3 C c 01.16019 ASBESTOS continued fibers liter suspected of Heine ampniboie asbestos. 4. Dispersion staining shows 150 anthophyllite fibers gram of sample. 5. Transmission electron mi croscopy shows 5 10* antho phyllite fibers liter of sample. The AEI Scientific Apparatus. Ltd. EMMA-4 (Figure 4) only recently installed in our labora tory will undoubted!) be the ideal instrument for the detection and identification of very fine asbestos fibers. A combination transmis sion electron microscope and electron microprobe analyzer (EMA), it enables the microscopist to see the smallest fiber and to identify it by diffraction pattern and elemental analysis. Although a given sample mounted on a TEM sirid can be examined successive!) by TEN! and EMA. the advantage of being able to examine many particles in a sam ple with assurance of one-to-one correspondence of particle size, shape, diffraction pattern, and elemental analysis is obvious. We have already applied this instru ment to some asbestos samples with excellent results, and expect it will be the instrument of choice for such samples in our labora tory. The monitoring of asbestos as a contaminant in our environment is an excellent example of one important problem solved by microscopy. The importance of choosing the proper analytical tool and having a w ell-trained'op erator is also emphasized by this application to asbestos detection and identification. Figure 4 EMMA-4, a combined transmission electron microscope and electron microprobe analyzer. ' F.O. BOX3S E. BLOOMFIELD) NT 14443 rrahfBana 315/657-6151 - rz e Peace' service Caro No. 69 13 APRIL 1974 DOW 05608