Document MJmYY6KmmYvmLK0rNE2J8Vb59

5 90-2184 inter office memo TENNECO CHEMICALS, INC. To J. T. Sweeney At Flemington From D, Bord At Flemington Subject VCM Control Report for the Period: 12/15/79 to 12/21/79 Date January 23, 1980 Copy to W. R. Fogelsanger D. M. Hershkowitz F. W. Kanzler F. S. Klopp R. A. Loj ewski S. P. Robbins* M. K. Rosen C. F. Rothenbeck G. I. Rozand P. D. Ruane P. R. Scarito D. 1. Scofield J. T. Sweeney M. E. Wagshul liable II Only Area VCM Average Level % 1 ppm Number ^100 ppm Reactor Building 1.2 3.6 5 Recovery Comp. Room 4.2 9.8 27 General Area 0.1 0.5 0 Pilot Plant <0.1 0.1 0 Parshall Flume 0.1 1.3 0 A reactor gasket leak and the dismantling of a recovery line were the causes of the 1.2 ppm Reactor Building average. Bendix TWA Analysis: The computer TWA values for the Utility Operators were above 1.0 ppm. This classification was pro tected by the use of breathing air. WDB:ms W. D. Bord ^ 01149G INTER-OFFICE MEMO TEMMEGO CHEMICALS, IMG To W. D. Bord At Flemington From P. D. Ruane At Flemington Subject VCM Control Report for the Period: 12/15/79 to 12/21/79 Date January 23, 1980 PV TO W. R. Fogelsanger D. M. Hershkowitz F. W. Kanzler F. S. Klopp R. A. Lojewski S. P. Robbins* M. K, Rosen C. F. Rothenbeck G. I. Rozand P. R. Scarito D. I. Scofield J. T. Sweeney M. E. Wagshul *Table II Only Attached is a summary of the Flemington Plant VCM levels as determined by the Computerized Area Monitoring System for the week of December 15, 1979 to December 21, 1979. PDR:ms PojuX^). Pi P. D. Ruane 011497 TABLE I AREA MONITORING SYSTEM - FLEMINGTON Weekly Summary Period: 12/15/79 to 12/21/79 Number of Readings & Percentages Area Reactor Building AVERAGE PPM,VCM 1.2 Total Samples 4,992 ^1 N% 184 3.6 >5 N% 132 2.6 ^25 N% 50 1.0 7*100 "N % 5 0.1 Recovery Comp. Room 4.2 768 75 9.8 71 9.2 58 7.6 27 3.5 General Area Pilot Plant 0.1 <0.1 3,840 3,072 21 0.5 4 0.1 19 0.5 1 1 0.03 0 0.03 0 0 0 0 0 Parshall Flume 0.1 384 5 1.3 0 0 0 0 0 0 PDR:ms P. D. Ruane 011498 FLEMINGTON TIME-WEIGHTED EXPOSURE AVERAGES CALCULATED FROM BENDIX MONITORING DATA 18/15/79 TO 12/81/79 JOB CLASSIFICATION TWA TABLE II POLYFOPMAN V AIR POLYFORMAN WO AIR SHIFT FORMAN W AIR SHIFT FORMAN WO AIR relief Foreman w air RELIEF FOREMAN WO AIR REACTOR OPER-CHRG W AIR REACTOR OPER-CHRG WO AIR REACTOR OPER-DUMPG W AIR REACTOR OPER-DUMPG WO AIR REACTOR OPER-RELIEF W AIR REACTOR OPER-RELIEF WO AIR UTILITY OPER W AIR UTILITY OPER WO AIR DRYER OPER WAREHOUSE SUPERVISOR WAREHOUSEMAN-BAGGER RELIEF OPER W AIR RELIEF OPER WO AIR MAINTENANCE FORMAN MECHANIC SHIFT MECHANIC DAY BOILER OPER MAINTENANCE CLERK EFFLUENT MAN W AIR EFFLUENT MAN WO AIR QC TECHNICIAN QC SUPERVISOR GROUP LEADER ENGINEER TECHNOLOGIST TECHNICIAN W AIR TECHNICIAN WO AIR MAINT TECHNICIAN RESIN PLANT GENERAL AREA PILOT PLANT .1 .2 .1 .2 ..l . 3. .1 .1 .1 .5 .1 .5 .1 1.3 .0 .1 .1 .| .| .1 .2 .1 .1 .1 .2 .2 .1 .1 .3 .2 .1 .1 .1 .0 011499