Document MJRpoKgaM682nqzY1e5rJOXYx

Mr. Ralph Sarla Union Carbide Nuclear Company Sterling Forest Hr. C. E. Brown Mr. K. W. Lentz Dr. Nale July 29, 1963 6.C.***. Sterling Forest^'flant t'.HJ a P Dear Ralphs The following are the particle counts for air samp collected at the asbestos development facility at Sterling Forest, July 25, 19o3. Location MPPCF Remarks ; Mezzanine above bagger 3.9 2.0 3.0 3.1 Bagging CMS-mechanically refined. No visible dust lost from exhaust system. Traffic doors wide open. Alongside bagger operator Some dust loss in beating 5.-4 bags to settle product. 8.5 *5..e2 The diameters of the fiber were as reported before (7/17/53) generally from 0.5-1.2 microns but some smaller sizes were observed. The lengths were mostly from 0.9-10.0 microns but there were some shorter and a few as long as 30 microns. A majority of the particles could not be identified as fiber. The average definitely identifiable fiber content of all the samples wa3 32 per cent and the range of fiber content was 2939 per cent. Examination of twenty different fields of dust that were allowed to settle on a glass slide on the mezzanine above the bagger showed about the same average identificable fiber content. It is possible and perhaps probable that most of the unknown particles were unopened fiber. It is interesting to note, however. Mr. Ralph Sarla -2 July 29# 19^3 that the scarcity of distinguishable fiber in the air samples was similar to findings reported by the Penna. Dept, of Health in examination of an asbestos textile mill, and by the Metropolitan Life Insurance Co. in a summary of a series of studies made in textile mills throughout the Dnlted States. Actually, both sources reported smaller percentages of fiber than we have found with sample contents ranging from 1 to 26 per cent. - I don't know what significance the different Bhaped particles have as far as exposure of personnel is concerned. I still believe It wise to observe 5 million particles per cubic of air as the maximum permissible dustiness and I believe we can stay within that limit with our process. Yours very truly. PWM/en Paul V. McDaniel Industrial Hygiene Engineer I