Gar-Wood Engineering Company
4196 Bellevue Avenue
Detroit, Michigai
Gar-Wood Balanced Heating Unit
A complete unit, shipped ready to un
crate and install. Requires only few hours to make necessary pipe connectionsand put burner in action. Completely automatic.
With minor changes can be adapted to bum either oil or gas with equal efficiency. Made of Armco Iron, electrically welded into one solid unit.
Uses counter-flow principle of heat transfer, in which water and hot gases flow in opposite directions.
Thoroughly tested , and stamped with
approval of the American Society of Mechanical Engineers.
L--Length without insulation. ..........inches
(Length with Insulation)....-___ ...........inches W--Width without Insulation........... .......... inches
(Width with insulation)......................... . inches H--Height without Insulation..........................inches
(Height with Insulation). .. ..................inches O--OveraiTLength.. .......... ...... ........ ...... inches
D--*Donr Clearance fromBoilerCenter........... inches
N--Size'of Steam'OutJet...... ........................... inches
F---Oil Line (Copper Tubing........ t.
:--
p__U.--S- tv
30
(Two) 2'(h
49V4
W
Capacity hosed.on 60 B.T.V. per aj. ft. xlearn Tnduliwn. ffot Water capacity IBs eteam capacity. Net ratinaeaBamfornormal
losses tn risers and retvme
GAR-WOOD BUILT-IN HOT
WATER HEATERS
Tapped for either internal orexternal domestic hot water heaters. ABuilt-inHotWater Heater that will provide con stant supply of warm water at very low cost can be supplied. Five sizes with the Aquastat temperature control; 40 g. p. hr.; 60 g. p. hr.; 80 g. p. hr; 120 g. p. hr. and 180 g. p. hr.
"Tar 1200 1300
104
1832 275 200 152 300,180
2(00 (600 2400
(28 2175
275 225 199
*eter Line loors RemovsblJj lH at Hinge
626
V
Boilers, Oil and Gas
Leader Boiler and Heater Company
176 West Adams Street, Chicago, Illinois
__ kOlSftCjf)
"THE KOOLSTACK LINE"
. Oil and Gas Fired Domestic Heating Boilers Oil and Gas Fired Industrial Boilers
Oil and Gas Fired Warm Air Furnaces Economizers for Oil Burners
The Koolstack System of Heating comprises a combination of principles; and arrangement of design particularly adaptable to intermittent auto matic firing with gas or oil.
The Boiler' and Burner are built for each other--A Complete Unit--Very Compact--suitable for in dustrial as well as domestic heating.
Bulletin OFD--oil fired domestic boiler for steam, vapor or hot water, also process work.
Bulletin GFI--gas fired industrial, also domestic heating.
Boilers are built to A.S.M.E. specifications. Burners are listed as Std. and1 labeled by Underwriters Laboratories.
Bulletins covering gas and oil burning warm air furnaces, built of steel, one piece, leakproof, now on the press.
SPECIFICATIONS LEADER KOOLSTACK OIL-HEAT SYSTEM
STEAM AND HOT WATER HEATING
Type No.
Net Rating
Sq.Ft. Note*
Approx. Width . Width
Ship. Wt, Boiler
Over Ail
Complete Leu Ow With Casing
Asscro. ing. Inches Note t
Height Over
AU
Inches
Length Over
AU Inches
S-2815 750
1925
28 ' 33%
56% 64%
S-28J8 noo
2580
28
33%
58% 74%
W-2815 (200
(925
28
33%
58% 64%
W-2818 1700
2580
28
33%
58% ' 74%
Size Smoke Outlet Inches
9
11
9
II
Size Sc No. Size St No.
Flow
Return
Openings Openings
Inches
Inches
Height Water Level .
Inches
one 4*
two 3*
41%
one 5T two 4* 41%
one 4* one 5*
two y two 4*
Hot Water Boiler
Crating increases over-all measurements by 4" on the width, 12" on the length, and
on the height.
Units are crated complete, including burner in position. Knocked-down units are crated with burner in separate crate; this shortens crate length 18".
Both the No. 2815 and 2818 Units will pass through a 28" door.opening with casing removed.
*Notb.--To determine the size of boiler needed, add only the U3ua! percentage for pipe losses. INote.--The over-all measurements refer, to'boiler set up, ready for use.