Document MJJr1dMdD8nLGj3NJ8njwOR1L

United States Department of the Interior BUREAU OF MINES Denver Federal Center, Building 20 Denver, Colorado 80225 Health and Safety Technical Support Center January 28, 1972 Mr. F.H. Larrison, Resident Calidria Asbestos Plant Union Carbide Corporation Mining and Metals Division Box K King City, CA. 93930 Manager R C i V -c. 3 FEB 1'97? ucc - CALior.:.\ kins -;ty. r: Dear Mr. Larrison: Enclosed is a report covering the asbestos dust (health) survey of October 4-6, 1971. Thank you and members of your staff for cooperation during the survey. * Sincerely, Glen W. Sutton Chief, Denver Technical Support Center cc: R.J. Kronkhyte, Maintenance Supt. and Safety Engineer UCC 023915 UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF MINES HEALTH AND SAFETY TECHNICAL SUPPORT . HEALTH STUDY (ASBESTOS DUST) ' KING CALIDRIA ASBESTOS PLANT KING CITY OPERATION UNION CARBIDE CORPORATION CITY, MONTEREY COUNTY, CALIFORNIA October 4-6, 1971 By Walter Bank, Mining Engineer Amin N. Alameddin, Mining Engineer Kenneth L. High, Mining Engineer V ti Z-JL -- hr'. /'/ .. - 9 - r 4i,i /s.cWv'V-a>/-risiiy' DENVER TECHNICAL SUPPORT CENTER Mr. Glen W. Sutton Chief Originating Office S. Bureau of Mines, Health and Safety Technical Support Center Denver Federal Center, Building 55 Denver, Colorado JJ0225 4-7953 UCC 023916 V UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF MINES Mine: Calidria Asbestos Plant Company: Union Carbide Corp. Mining and Metals Div, Operated by: same as above I.D. No: 40013-00-04-027 Underground ___ Open Cut __ Survey by: Walter Bank, Amin Alameddin, and Ken High Location: King City, Monterey County, California Survey dates: October 4-6, 1971 DISTRIBUTION: Company officials: F.H. Larrison, Resident Manager (3) R.J. Kronkhyte, Maintenance Supt. and. Safety Engineer ' Assistant Director--Health and Safety Technical Support (2) Assistant Di re ct o r--Me t al and Nonmetal Mine Health and Safety (2 Originating office: Technical Support Center, Denver, CO. (2) State agencies: California Div. of Industrial Safety Dept, of Industrial Relations 455 Golden Gate Ave. San Francisco, CA. 94102 Attn: Walter Van Sandt (1), Edward Davies District Manager: Allan Look, Alameda, CA. Subdistrict Mgr: Howard Poland, Alameda, CA. (1) Other: Ernie Piersol, Safety Director Mining and Metals Division Union Carbide Corp. P.O. Box 1049, Grand Junction, (2) ' CO. 81501 UCC 023917 4 ; 7 95i Identification No. 40013-00-04-027 INTRODUCTION This report Is based on a study made pursuant to Section 5 of the Federal Metal and Nonmetal Mine Safety Act (80 Stat. 772, F.L. 89-577, 30 U.S.C. 721-740). The report supplements the Health and Safety Report dated September 20, 1971 pre pared by J.L. Weddle of the Bureau's Alameda, California office. GENERAL INFORMATION The Calidria Asbestos Plant, King City operation of the Union Carbide Corporation, Mining and Metals Division, is located about 5 miles southerly from King City on Wild Horse Road about one mile from its Interchange on U.S. Highway 101. The mailing address is Box K, King City, California. Mr. F.H. Larrison was Resident Manager and R.J. Kronkhyte was Mainte nance Superintendent and Safety Engineer. Mr. Larrison * accompanied the investigators during part of this study, and visual observations and provisional recommendations were discussed with him at the end of the sampling campaign. . Total mill employment consisted of 50 men as of October 5, 1971, the date of the survey. Production crews worked three 8-hour shifts, 5 days a week, and maintenance and distribution crews worked the day shift. There were 16 salaried employees. The mill went into production in 1963. The plant uses a wet milling process for the chrysotile asbestos and produces four types of material. The standard grade is bagged and shipped in perforated multiwall paper bags of 50 pounds (pellets), 40 pounds (open fiber) and 30 pounds (open fiber) capacity. The Super Standard is ground finer and is bagged in 30-pound bags. The High Purity asbestos, used for paper manufacture, is bagged into 50 , 40 , and 30-pound bags. The Resin Grade (a specialty product) is bagged In 10-pound bags provided with plastic outer sheaths. The product is transported by truck or- by the Southern Pacific Railroad; however, it is never shipped in bulk. The asbestos is shipped to many points throughout the United States and overseas. Estimated pro duction for 1971 is 20,000 tons, and the life expectancy of the operation is indefinite. The following structures are located on the property: 1. The mill, which is a metal building of 14,400 sq. feet. 2. A wooden office and laboratory building of 1,320 sq. feet. 3. A two-story metal warehouse-office-shop building of 2,40 0 s q. fee t. A;795o UCC 023918 4. A metal, open-sided product storage shed of 10,960 sq. feet. 5. A rubberized-cloth inflatable building of 6,426 square feet. An ore stockpile, estimated to contain about 35,000 tons. was located across the roadway, Ore was delivered to the stockpile by a 25-ton capacity truck and trailer, dumped on top the stockpile, and pushe d by a bulldozer to blend the ore and to provide a more 1 evel surface or roadway for the ore truck. A front-end loa der with a 2 1/2-yard capacity bucket trammed ore from the sto ckpile to the loading point which leads to the COM bin - th e start of the ore processing. A tailings pile, estimated at 15,000 tons, was immediately adjacent to the ore stockpile, Product recovery was 50 percent; the 50 percent wet tailings was stacked by means of an in dined belt conveyor. When the waste pile becomes too large and overflows onto the roadway, the waste pile is cut down to size and the waste is hauled to a nearby ravine by a means of self-loading paddle wheel scraper. While the dust survey was in pro ces s, M. W alter A. Van S andt, Indus trial Hygiene Engineer and Mr. Ed D av ies , Safety En gineer of th e Cal ifornia Department of Ind us t ri al Relations vis i ted the o pe r at ion , discussed our s ampli tig te ch niq ues, coll e c ted sever al s a mple s for record purposes , and f urnished the write rs wi th i nformation on this an d oth e r asbestos pi an ts . DESCRIPTION OF STUDY Asbestos airborne dust is plant of this character. demonstrated to cause the and lung cancer. the overriding health hazard in a Airborne asbestos dust has been pneumoconiosis called asfjes tosis All control measure s applicable to mineral dust control can be used for airborn e asbestos; however, the more hazardous nature of asbestos requires more stringent adherence to good control practi ces. At the Calidria mill, the following conditions and prac tices were noted: ' 1. The stockpile was kept wet most of the time. Reportedly, the ore contains 20 percent moisture. 2. Prevailing winds are from the north, and blow the stock pile-created dust away from the mill. 2 A i 7/ 95 UCC 023919 3. The front-end loader, normally used for tramming ore from the stockpile to the ore bin, was provided with an enclosed cab with blower attachment. The spare front-end loader (used during the survey) was not provided with an enclosedcab. 4. Offices were enclosed and isolated from dust-producing operations. 5. The asbestos processing was a wet operation. 6. Production of a pellet prior to drying decreased dust creation and dissemination in the later packaging and shipping operations. 7. Housekeeping was a continuous process. Outside areas were cleaned as needed. Wet areas in the mill were washed down at least once a shift. Dry areas were swept with a push-broom and the sweepings from the bagging and palletizing areas went back into the circuit. _ 8. Both the Standard and High Grade processing systems were provided with dust collectors. * 9. A dust collector system was being installed in con junction with the bagger; the incomplete system was used currently to vacuum employees clothing. 10. USBM-approved respirators were worn by (a) the dozer operator; (b) the bagger operator; (c) the palletizer operator; and (d) the front-end loader operator. 11. The assay office was air-conditioned and provided with filtered air. A fume hood was available. A vacuum cleaner was used to clean the bench and other equipment. 12. The accounting and other offices were air-conditioned and provided with filtered air. All offices were swept regularly. 13. In the electrical shop, compressed air jets were used to clean equipment. This cannot be considered a good-housekeeping practice. 14. An engineering surveillance program was maintained. A monthly sampling program was carried out by a resident laboratory technician who sampled seven locations using a Unijet pump and Millipore filters. Mr. Paul W. McDaniels, Industrial Hygiene Engineer for Union Carbide Corporation, reportedly visits the plant twice a year to check the program and to make pertinent recommendations. 3 * A UCC 023920 15. A medical surveillance program was reported in effect. The reported program included a pre-employment physical examination followed by an examination every three years until age 40; thereafter, an annual physical examination is p rovide d. During the survey sampling, the weather was clear and dry with a slight wind blowing intermittently. At noon, the temperature was about 90 degrees and the humidity was about 13 percent. . The effectiveness of the control measures will be dis cussed later in this report. ' Sixty-six sample's were collected. Of these, two Nuclepore samples were submitted to Dr. Phillip DeNee, Safety Research Center, Bruceton, Pennsylvania for evaluation. Results of his work will not be included in his report. A settled dust sample and a sample of the purified product, collected from the filter press, were submitted to the Field Health Group analytical laboratory; results of these analyses are included in Appendix I. Sixty-two airborne asbestos dust samples were collected on membrane filters using pumps > calibrated, at the mill office to pull 1.4 liters per minute of air; these samples were counted in the DenveT Field Health Group laboratory at approximately 460 magnification with phase contrast illumination according to the method established by the U.S. Public Health Service. Full-shift exposure samples were collected of three individuals who were exposed presumably to high asbestos dust concentrations; sufficient samples were collected of other representative individuals or of locations where men worked to indicate the dust exposure levels. DISCUSSION AND RESULTS In 1967, the published TLV 1_/ was 5 mppcf (millions of par ticles per cubic foot of air) for asbestos-bearing dusts when collected conventionally with the impinger or midget irapinger and counted conventionally with the standardized light-field counting method. The number concentration represented the visible fragments (small) of asbestos fibers plus the many associated mineral dust particles. In 1968, the published "Notice of Intended Changes" proposed that (1) the 5 mppcf be reduced to 2 mppcf; and (2) an alternative figure of 12 fibers/ml (.fibers per milliliter) greater than 5 microns in length be adopted -- this figure 1_/ Threshold Limit Values for 196 7 , Reconmen ded and Inten ded Changes; American Conference of Governmental Indus trial Hygienists, 1967. f 4 A i 7950 UCC 023921. was to be based on the membrane filter method at 430X phase contrast magnification. The above two proposed changes were retained in 1969; in 1970 the published proposed changes (1) dispensed entirely with the impinger sampling method and its number concen tration figure; and (2) recommended that the alternative value be changed from 12 fibers/ml greater than 5 microns in length to 5 fibers/ml greater than 5 microns in length. In 1971, the "Notice of Intended Changes" retained the 1970 proposal, and specified the membrane filter method at 400-45QX magnification phase contrast illumination. Also, an excursion limit not to exceed 10 fibers/ml may be per mitted for 15-minute periods each hour up to five times daily. For purposes of this health study, it is believed that the 1971 proposed TLV figure and sampling method provides the ' best indication of the asbestos dust health hazard. Thls,, value has also been accepted by the U.S. Department of 5 Labor and on December 7 an emergency standard of 5 fibers/ml was published in the Federal Register. Therefore, the pro posed 5 fibers/ml (on a time-weighted basis) is used as tiie threshold limit value. Fiber concentration and pertinent data for the individual airborne dust samples are listed In Appendix II. Fiber con centration data are summarized in Figures 1, 2, and 3. Figure 1 summarizes the time-weighted exposures of three men. The bagger operator was exposed to eight times the TLV and had a one-hour exposure of 12 times the TLV figure. The palletizer operator, working nearby, was exposed to 6 times the TLV and also had a one-hour exposure of 12 times the TLV figure. Both men were provided with U.S. Bureau of Mines approved respirators which they wore when working in obviously dusty atmospheres. The exhaust system at the bagging operation was inadequate to control the spillage and dust emission, and as the newlyfilled perforated multi-wall bags were conveyed to the palletizer, dusty air seeped from the bag's pores and con tributed to the asbestos dust load of the ambient air. When bags broke during the bagging operation, the exhaust system at floor level failed to capture the spillage; sweeping the dust spillage to the floor launder contributed to the dust load in the air. As previously mentioned, an additional dust-collecting system was in process of installation at this area. 5 UCC 023922 A v7 952 The exhaust system at the top of the palletizer admittedly was not working properly and required repairs. When broken, bags were dropped to the floor beneath the palletizer, and subsequently the bags and asbestos were removed. The foreman's time-weighted exposure was 7.6 fibers/ml with one sample recording a one-hour exposure of four times the TLV figure. The foreman made his rounds unaccompanied by the man collecting samples. The source of the dust con tributing to the foreman's exposure is considered (provisionally) to be the general mill atmosphere. Other workers' airborne asbestos dust exposures were obtained on a when-sampled basis. As shown in Figure 2, the exposures of the mechanic, the bagger of the resin-grade asbestos, and the filter-press operator were within acceptable limits when sampled; the exposure (arithmetic average) of the loader operator was six times the TLV figure with a one-hour ex posure of eleven times the TLV figure. A number of working areas were sampled to assist in evaluating the workers' exposures; the airborne asbestos fiber concen trations are summarized in Figure 3. Mine yard "general atmosphere" samples collected during the greater part of the workday suggest that wind dispersal from the ore stockpile or tailings pile was not a significant factor in the workers' samples collected in the mill. But it is recognized that at times the wind direction and velocity may become significant factors in contributing to a hazardous dust environment. Low asbestos fiber concentrations were obtained in the accounting office, the main (upper floor) office, the welding shop, and the assay office. The roll mill area of the mill had an arithmetic average concentration of 8.0 fibers/ml. The high concentration of 17 fibers/ml of sample B-105 indicates a need for better dust control.measures at this "wet" operation. The cause of this high concentration was not apparent. The foreman's office sample results yielded an arithmetic average of 7.5 fibers/ml with a high concentration in sample B-23 of 11 fibers noted between 1:38 and 2:38 p.o. The office door opened to an area partitioned from the dusty bagging and palletizing area, so the specific cause of these concentrations was not obvious. The dust concentrations are provisionally attributed to the ambient air dust load and the dust from the workers' clothing during the time they occupied the office. _ 6 9~7 /o UCC 023923 The electric shop area sample results yielded an arithmetic average of 3.2 fibers/ml. This concentration is attributed largely to sample B-103 which was collected during a period when, a compressed-air jet was used for cleaning some electri cal equipment. CONCLUSIONS AND RECOMMENDATIONS The time-weighted exposures of the bagger and palletizer operator were very high. Although considerable effort has been made to control dust in the mill, air sampling revealed that the air quality is not satisfactory and must be improved. Engineering methods, such as, but not limited to the following re commendationsshall be used to meet the exposure limits prescribed in the standard. 1. Enclosure of operations to prevent spillage and dispersion of material shall, where feasible, be utilized. The bagger area should be enclosed, and if properly designed and operated, can protect the bagger and reduce the dust loacf of the- ambient air. The dust control system being installed should be completed. ** 2. Enclosures, hoods, and other devices to contain and collect material, especially airborne dust shall be maintained under negative pressure through the use of local exhaust ventila tion. 3. The air collected by the local exhaust ventilation system shall be cleaned through the use of adequate, well main tained bag collectors, or other devices equally efficient, and the filtered air shall be discharged outside the work area and not be recirculated. 4. Vacuum cleaning shall be used rather than manual sweeping or blowing with compressed air. 5. The dust collection devices and system must be maintained and utilized in a manner that will result in its operating in an effective manner. If the dust control system should fail, operations should be suspended until repairs are completed and the system is capable of maintaining dust concent rations below the standard. 6. Encapsulate the filled bags with plastic bags in the same way the resin-grade asbestos bags are handled. 7 UCC 023924 A ; 793 ! To diminish the exp os ure of the loader o re commendati ons are made ; 1. Keep the s t ockpile w et. 2 Provide an enclosed cab with filtere the spare lo ade r in use dur ing the s urve a c ab . on the loaders ; 3. Improve the housekee pin g in the i mme exa mple, the concrete ramp leading to th was hidden b ene ath spill ed o re. Po r The use of re spirators in the work area shal 1 not be conside red as a substitute for engineering cont rols and their continued use over prolonged periods shall n ot be permitted. However, to p rotect the workers prior to the application of engineering c ontrols which result in exposur es and/or concentrations fa elow the standard, respiratory protective de vices shall b e provided, maintained and thei r use required, The respirato ry protection program shall inc lude adequate-' training and supervision of employees in the testing of respiratory p rotective devices for fit befor e their use. The employees shall be required to test his respiratory . protective de vice before each use in order t o insure a proper f it. Respiratory protective devices to be used shall be limited to the following: 1. For an atmosphere c ontaining not more than 2 5 fibe rs/ml grea ter than 5 mi crons in length over an 8-hour a ve rage or mo re th an 50 fibers/ml over any p erio d of 15 minu tes , a reus abl e or single-use filter typ e re spirator, op e rat in g wi th ne gative pressure during the inh alation phas e of brea thi ng, approved by the Bureau o f Mines under S ch edu le 21 shal 1 b e us ed. 2 . For an atmosphere c ontaining not more than 250 fibe rs /ml greater than 5 microns in length over an 8-hour average o r mo re th an 500 fibers/ral over any peri od of 15 min utes , a powe red filter positive p ressura resp irator appro ved by th e Bureau of Mines und er Schedul e 21 B shall be used, The tailings pile, when dried, is an obvious sour ce of air- born e dust during windy condit ions. Keeping the t ailin Ss pile we t continuously and removin g it to a more d is t ant lo cati on will minimize dust conditi ons in the mill. shop, an d of fi ce are as; however, other meas ur es must be tak en to mini- mi z e it s impact on the c omiunity envi ronment. UCC 023925 A , 796n A i 7- 9 3 3 h9* < P> UCC 023926 z F ig u re 1. A sbestos F ib e r C o n c e n tra tio n s in M ill, T im e-W eighted E xposures 2 ST 4 n3 3 3rf p. O 3 M 3X c -i (mD 3 HS* I I O 3 3 sr (D 3 03 3 3a H* n> o. n 33 H* 3 a A i 7 9 8 -r UCC 023927 HFj OQ C H 10 LJ o ro 3 1(0 >oa o* (0 H to o rr O05 oB H* o* 15 3 H mO h to O 3 O o 10 33 r* H 3 s: <0 3 I Crt 3 T3 h-1 ra CL w 3 m H* m Asbestos Fibers/ml-, >5 microns in length 2O! IO 1--1 H* M NJ ^ Hi in Q l*n o- in o CQ 3 T33 ro 0 Lower office, accounting UJ Upper office, main I Cj r Jc-i Electrical shop k FSU) [. , . -O -- Jj Welding shop 3 lAo o> t* o I es >H <(B 3* fi Co 3fO TO ! TO =r A ' 7 9 S UCC 023928 APPENDIX I Mineral Analyses S ample No. B-902 B-904 Des crlption Percent Free Silica Filter-press product ' 0 ' Settled dust near COM bin 4 Remarks Diffractometer scan showed broad lines identified as being from serpentine 1/ Same 1/ Additional mineral and elemental information will be added to this' report when available. . UCC 023929 A,7963 Ha c o M no M H s H m A c o H 4J CS H 4) & O **. s o H 4-1 tfl U Q rJ - O co CS H \fl co o^ co CM CS m m cs m m <3* DO p SO v3 a DO H d 00 JJ d cn CO 43 * H 00 M DO 00 ct <U *i4 o 00 iD CO N 4^ 00 T4 43 O c U *rH 0) * 00 iH u o oo pH cn CL N o ** u (0 3 <0 * *o ed & *d j CO Jl O 43 O P !> >4 * *H C3 - }n| CL L U ^ L M J -H cl a A* 14 14 * o 44 o O i4 4 O O o o CXi o H O TJ o xJ oO ood 1-4 --1 pH <u 1-4 4) CO H i--l iH i-4 d MH 44 DO 4H -4 CO 44 44 44 <M <d Jh 00 rH D 1--1 O i--t <0 -4 cd f*4 rH rH i--t r4 i-H 4H i--1,, JO rH CL 6 H f-4 r4 fH CJ xH H *3 -r-0 H iH -H S cn 2 35 X X CM . 00 CM CO vo lO CO iH rH i-4 sr CS m sO CO <11 V 00 <J o d C 00 d H cd *c cd N c 00 -H c OO -H DO 00 4) d u 4) d 44 d d U h ca U H 0> H c 00 M C OO rH DO 00 *t4 00 <u *H OO rH oo oo cd td cx cd CQ cO <d cd 0 43 O M e 43 CL 43 43 A CO A A A A A ex A A Xl u u 44 14 M u d M 4 o * o o 4*4 o O o d O o ex o O o o H o U O o Cd o o d r4 0) pH iH i--l r4 0} i-4 (--i a; r4 rH d s44 44 44 44 44 H 44 44 rH 44 44 cd 14 o <u i--l pH 1-4 0 pH *H i-4 iH 1--1 r4 1-4 t r4 i--l 44 tH uU i--l rH i-4 r4 o H *xrf *aHs E H H EX t4 sX d o 0) PJ o r-. m m VO O o a o m -<r n CO CO CO o xH u CO ON o rH CS CO 4J- vO h CO o o i--i pH i--l i--l r4 rH oc d ri rH u u r-- o tn CO m n VO O a d O cn <r eo F4 CO CO CO a 44 oo 00 o> O r4 CS CO 'dcn CO o o o r4 r4 iH rH i-4 O 00 i--l o 00 o uo sr CO CO fO o 00 CJ> O H CS CO < vO o o rTM r4 i-4 rH i-4 r4 VO r--f Ch < o CO <r O m < CO CO CO 00 00 O i--l CS CO -T o o O i--1 i"4 r4 i--l rH a) ai m fi o ai rH a o O o"> r rH <S 2; .h hi- r-. H H H M (N <S I 1 I I I I I I cn os a pq SQ 05 03 05 05 to o pH <r 00 cs cs m oo rH rH rH cs cs ii ii i1 |1 11 1I 1} ii PQ CQ P5 CQ cq CQ CQ eQ UCC 023930 A ; 7967 APPENDIX II ' * UCC 023931 s ample No. B -3 Date 10/5/71 B -6 B -9 B -12 B -16 B -20 B -2 7 B -28 B -119 10/5/71 B -120 B, -12 1 B -122 10/5/71 B -123 B -124 . B -125 10/5/71 B -126 B -12 7 B -20 3 B -204 B -207 10/5/71 B -105 10/5/71 B'-111 B--116 Sampling Time Start Stop 0813 0908 0909 0949 1053 1206 1306 1403 1501 0949 1052 1206 1306 1403 1500 1601 1225 1330 1431 1325 1430 1531 1243 134 3 1345 1446 ' 1445 1546 130 2 1402 1402 1502 1502 1602 1050 1204 1204 1306 1306 1452 0923 1023 1025 1126 . 1125 1226 Job Title or Des cription Fo reman . Fib e rs /ml Loca tion/Operation >5 mi crons Asb es t os plant , rounds , BZ . s ame as ab ove. s ame as above. s ame as above. s ame as above. s ame as above. s ame as above. same as above. making ' 9.8 5.1 3.5 20 5.3 7.3 3.4 3.5 Me ch anlc Mill , va ried locations; repai r work , BZ . s ame as above. s ame as ab o ve. 0.1 0,0 0.1 Bagger, resin grade Mill, re sin grade bagging are a. misc. operations. s ame as ab ove. 8 ame as above. 2 .9 BZ. 1.4 1.4 Loader operat or Outsi de mill, tramming ore , B Z. s ame as above. same as ab ove. 11 20 57 Filter press ope rator Mill, fi Iter press op . press; BZ. s ame as above. s ame as above. , area. 0.5 0.5 0.23 Mill, TO 11 mill gen era,1 atmo. s ame as above. S ame as above . feed; 17 5.3 1.6 2 CQ CO CD APPENDIX II UCC 023932 S ample No. B -15 Date 1G/5/71 B-19 B-2 3 B-26 S ampling Time Start Stop 1150 1236 1237 1338 1438 1337 1438 1600 Job Title or Description Filter press operator Location/Operation Fibers/ml >5 microns Mill, foreman's general atmo. same as above. s a me as ab ove . 1 same as above. office; 9.0 6.9 11 3.3 B -201 B-205 10/S/71 10 30 1248 1248 1508 Mine yard @ flag pole; general atmo. same as above. 0.000.17 B -20 2 B -206 10/5/71 1040 1256 1256 1500 Mine yard, welding area; general atmo. same as above. 0.044 0.26 B -10 1 B -10 6 B-11Q 10/5/71 0815 0916 1017 0915 1016 1117 Assay lab.; general atmo. s ame as above. same as above, 1.7 1,9 0.12 B-102 10/5/71 0850 B-107 0952 B-112 'Nl 1055 CO B-103 10/5/71 0904 CD Cu B-108 1005 B-114 1106 0950 1052 1155 1004 1105 1206 i! Lower office, accounting; general atmo. s ame s ame 1.1 1.5 0.2 Electrical shop; atmo. s ame as above. same as above. general 9.3 0.29 0.10 B -10 4 B-109 B -11 3 10/5/71 0913 1014 1115 1013 1114 1215 Upper office; gene.ral atmo .0.99 s ame as ab ove. ' 0.33 same as above. 0.10 3 APPENDIX II Sample No . B-115 Date 10/5/71 B-I17 B-118 Sampling Time Start Stop 1242 1342 1342 1^42 1442 1542 Job Title or Description Location/Operation Fibers/ml >5 ml crons Welding shop; general a t mo, s ame as above. s ame as above. 0.31 0.73 0.00 UCC 023933 NJ O January 18, 1973 Hr. Frank Warm Senior Satfsfcjr Englaetr ^tate of California Dept. of Induetrisl Belatiana --iriroK of Industrial Safety T55C Maripoaa 5t.f Soaa *>065 !'r?mo, California 93721 lear Xr. Warrant - Aa required la your Accident Prevention Keport of 11-30-71* the tagging operator ha* boon provided* and is required to wear* an air supplied hood unit while parforsaiag tha Cities of bis jrt. Tie otter operator*, la tin pallatise* area* has been supplied with a 21-B rated cartridge type res pirator. The two opermtare are rotated during the shift bo that neither operator opcode full tine ia the cartridge respirator. Cur cospaxxy Industrial Hygienect* Xr* P. W* McDaniels* has checked the air supplied hood unit under operating conditions aad has dettrained that the hood internal ataoephera to leea than TLV. Very truly yours* Floyd H. Larriooa* Jr. Manager* King City Operations /clg cc: E. A* Pi email S. J. Krockhyte UCC 023934 A ; 7 97 1