Document MGzj5jLLJ3grpgM23BGarrgq7

* UNION CARBIDE CORPORATION Specialty Chemicals Sistersvi1le, WV April 11, 1986 MEMORANDUM TO: Department Coordinators First Line Supervisors Planners/Schedulers Second Line Supervisors Staff COPY TO: Bulletin Boards FROM: G. W. Wulfert SUBJECT: Treatment of Asbestos in Insulation Weatherproofing CORRECTION TO SUBJECT MEMO DATED MARCH 31, 1986 (PLEASE DESTROY THE MARCH 31, 1986 COPY) Recent information brought to our attention that the insulation weather proofing (Jaxsan-600) that we have been using for years has 4.33% asbestos fibers in it. We have stopped using Jaxsan-600 and have switched to a lesser quality product (WC-5) which is asbestos free. We have deep concerns on just how to handle any and all asbestos without a hazard to our people. All the information that we have to date shows that the asbestos fibers in Jaxsan-600 are bonded in latex and do not present a hazard. We are seeking more information and, more importantly, are doing monitoring of individuals and jobs in the removal of Jaxsan-600 to further qualify this information. It is felt that until more specific information is obtained that extra (r) precautions, wearing of Comfo II w/magenta canister, which is the Type H ``good for asbestos" respirator, will be required of anyone involved in the removal or distribution of Jaxsan-600. For this interim period we will class all weather proofing in the plant as Jaxsen-600. We are in hopes that these measures are temporary and that appropriate, permanent procedures are short coming. Your cooperation can only enhance the safety of our people. GWW:ts NOTE: 1) Magenta Canister is Stores Code 7512-4610. 2) Magenta is what we've called purple in the past UCC 022465 UNION CARBIDE CORPORATION Specialty Chemicals Sistersville, WV .March 31-,-1906 MEMORANDUM TO: Department Coordinators First Line Supervisors Planners/Schedulers Second Line Supervisors Staff COPY TO: Bulletin Boards FROM: 6. W. Wulfert SUBJECT: Treatment of Asbestos in Insulation Weatherproofing Co 1 i I ' 11 i<\pL C ft'o/t Recent information brought to our attention that the insulation weather proofing (Jaxsan-600) that we have been using for years has 4.33% asbestos fibers in it. We have stopped using Jaxsan-600 and have switched to a lesser quality product (WC-5) which is asbestos free. We have deep concerns on just how to handle any and all asbestos without a hazard to our people. All the information that we have to date shows that the asbestos fibers in Jaxsan-600 are bonded in latex and do not present a hazard. We are seeking more information and, more importantly, are doing monitoring of individuals and jobs in the removal of Jaxsan-600 to further qualify this information. It is felt that until more specific information is obtained that extra precautions, wearing of Comfo II w/ftoHow canister ond dust cover, will be required of anyone involved in the removal or distribution of Jaxsan-600. For this interim period we will class all weatherproofing in the plant as Jaxsan-600. We are in hopes that these measures are temporary and that appropriate, permanent procedures are short coming. Your cooperation can only enchance the safety of our people. GWW:ts Vote.; 0 I'Ai'pCwtl IJ ISft Plfrt.t (kJL. / Ci.tfc*L pvispU UCC 022466