Document MGnVNEDYVVoDv5x79Y3oO55OV

INTERNAL I CORRESPONDENCE 1; UNION CARBIDE CORPORATION technical center PO. BOX 036 1, SOUTH CHARLESTON, WV 25303 lolNB"'i W. Seoular Qv'snn 701_40Q R. Brabbin - 701/1 P. D. Gossage - 701/4 J. E. Liana - 740/2 C. P. Maxwell - 701/2 R. E. McEldowney - 770/2 R. G. Rowe, M.D. - 791 R. E- Sergent - 725/1 P. D. Sherman - 701/2 July 20, 1987 EM&TS - HS&EAO: '.gingting Dept. Industrial Hygiene Asbestos - Background Monitoring Attached are the results of background Asbestos monitoring done in various buildings. Most samples were collected overnight, although a couple were collected for a specific reason - see comments. The only regulation that applies to our facilities is the OSHA standard of 0.1 fiber/cc Action Level. However, the generally accepted level for background Asbestos is 0.01 fiber/cc. We are below the 0.01 fiber/cc level, even in some unusual situations. If we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK 8Y: APPROVED 8Y: O-AasX-J Vance E. Stover Attachment VEStMAP:rab 2504P X- Manhar A. Patel UCC 024587 Date 1-26-87 1-26-87 1-21-87 1-29-87 1-29-87 2-5-87 2-5-87 2-5-87 6-4-87 6-24-87 6-25-87 6-25-87 2504P AREA ASBESTOS MONITORING* Sampling Time 17hrs 12min Air Cone* Fibers/cc <00087 Building 701 COMMENTS East end of basement hallway near caged area - under pipe chase. 15hrs 20min <0010 701 West end of basement in hallway near caged area. 7hrs 9min .005 704 Collected near the No. 3 boiler where powerhouse operators spend most of their time. 17hrs 2min <.0009 14hrs 38min <0011 I7hrs 24min <.0010 740 740/1128 770/237 Collected near the bins in the storeroom under the South wing service shaft. Collected in Room 1128 Instrument Shop - under the service shaft. Collected in the autoclave lab hanging between Autoclaves 14 and 17. 15hrs 38min <.0010 770/110 Collected in the fan room under service shaft. 17hrs 2min 2hrs 4min <.0008 <.0076 770/164 Collected in Service room near the doorway. 701-8asement Collected in basement near where insulators were repairing and cleaning up Asbestos in pipe chase above. 7hrs 26fnin .0074 8hrs 57min <.0017 lOhrs 41min <.0015 701/3rd Floor Hallway 705-HalIway 705-Hallway Collected in hall the day after extensive cleaning was done the evening before. Also, employees worked in this end approx. 4 hours on this day. Collected in the operating area hall between Cells 12 and 13. Collected in the operating area hall between Cells 4 and 5. *Total Fibers - No differential counting. UCC 024588