July 20, 1987 EM&TS - HS&EAO: '.gingting Dept.
Industrial Hygiene
Asbestos - Background Monitoring
Attached are the results of background Asbestos monitoring done in various buildings. Most samples were collected overnight, although a couple were collected for a specific reason - see comments.
The only regulation that applies to our facilities is the OSHA standard of 0.1 fiber/cc Action Level. However, the generally accepted level for background Asbestos is 0.01 fiber/cc. We are below the 0.01 fiber/cc level, even in some unusual situations.
If we can be of further assistance, please feel free to call us on extension 4779 or 3750.
WORK 8Y:
APPROVED 8Y:
O-AasX-J Vance E. Stover
Attachment
VEStMAP:rab 2504P
X-
Manhar A. Patel
UCC 024587
Date 1-26-87 1-26-87 1-21-87 1-29-87 1-29-87 2-5-87 2-5-87 2-5-87 6-4-87
6-24-87
6-25-87 6-25-87
2504P
AREA ASBESTOS MONITORING*
Sampling Time
17hrs 12min
Air Cone* Fibers/cc
<00087
Building 701
COMMENTS
East end of basement hallway near caged area - under pipe chase.
15hrs 20min
<0010
701
West end of basement in hallway near caged area.
7hrs 9min
.005
704
Collected near the No. 3 boiler
where powerhouse operators spend most of their time.
17hrs 2min
<.0009
14hrs 38min
<0011
I7hrs 24min
<.0010
740 740/1128 770/237
Collected near the bins in the storeroom under the South wing service shaft.
Collected in Room 1128 Instrument Shop - under the service shaft.
Collected in the autoclave lab hanging between Autoclaves 14 and 17.
15hrs 38min
<.0010
770/110
Collected in the fan room under service shaft.
17hrs 2min 2hrs 4min
<.0008 <.0076
770/164
Collected in Service room near the doorway.
701-8asement
Collected in basement near where insulators were repairing and cleaning up Asbestos in pipe chase above.
7hrs 26fnin
.0074
8hrs 57min
<.0017
lOhrs 41min
<.0015
701/3rd Floor Hallway
705-HalIway
705-Hallway
Collected in hall the day after extensive cleaning was done the evening before. Also, employees worked in this end approx. 4 hours on this day.
Collected in the operating area hall between Cells 12 and 13.
Collected in the operating area hall between Cells 4 and 5.
*Total Fibers - No differential counting.