Document MGmkwDNb6kxzbjgBk8Bpb9peV
Interoffice Communication
To J. H. McCulley, Jr.
From
o*t
Subject
P. L. Fetzer
September 13, 1974
Ambient Air Analysis - fla-mma Gas Leading 9-11,12
Concurrent testing was conducted on all loading operations using the Century Hydrocarbon Analyzer and personnel dosimeters. The grid survey of the dock area was omitted due to the short loading time for the Gamma Gas.
Our vent recovery unit was not operated during the loading although, accord ing to ship personnel, the ship vented through our vent stack during the loading. The ship's recovery unit was operating during the loading which indicates that the revision had been made on their vent piping to permit operation in series with our recovery unit although we were not notified of this change. No pressure buiid up on the vent line was indicated by the pressure gauge on the dock vent line. This lack of pressure on the vent line during loading substantiates the observations made during the loading of the Irene.
Two questions remain unanswered in my mind: Will our vent recovery unit operate with low pressure on the vent line? Does the lack of pressure build up indicate the vent recovery unit is being bypassed?
Problems were encountered during cargo sampling. The braided hose sampling line leaked at the braid on the end that connects to the sampler. High
hydrocarbon readings, > 1%, were obtained at the leak on the sampling hose.
Suggested improvements on the sampling apparatus include a larger sampling line and insulating this and all other lines in some manner.
High hydrocarbon analysis were obtained while disconnecting the hoses aboard ship. Both the liquid and vapor valves on the ship leak quite badly. The leak being so bad that it could be heard and felt while passing a hand over the opening. Personnel dosimeter data for this operation was quite high, 326.77 ppm TWA for a one hour exposure. A small amount of liquid vinyl was observed while inserting the flange in the liquid line on dockside. This occurred even though the purging and evacuation procedure had been followed.
CCR 000082132
PAGE 2 AMBIENT AIR ANALYSIS The data from the last few loadings indicates ttet a review of our loading procedures should be made by the people monitoring the ships. These pro cedures could then be revised if needed and would also reveal if shortcuts are presently being taken. A summary of the loading operation with all pertinent data is attached. P. L. Fetzer
be
CC: RDG, JAD
CCR 000082133
CONNECTING HOSES
FLANGE REMOVAL
HEEL SAMPLING HYDROQUINONE
ADDITION LOADING
SUMMARY OF RESULTS GAMMA GAS LOADING 9-11.12
)
Connection of both liquid and vapor line aboard ship vent well. Total hydrocarbon readings remained 25
ppm In the breathing zone. High readings were obtained
briefly when checking to determine if the eductor vas working by opening the nitrogen purge valve on spool piece. High hydrocarbon readings were obtained while removing the' flange on the- vapor line on- the dock when the eductor was turend off to permit'removal of the flange. Personnel dosimeter result .during the tine for both operation was 3.75 ppm.
While removing the flange from the liquid line, total hydrocarbon reading in the breathing zone ranged
between 6 and 100 ppm. The higher reading occurred
when the flange was first broken loose and the eductor is tinned off to permit removal of the flange. The valves on the liquid loading line are leaking indicated by the pressure increase once the eductor is turned off. Removing the blind permited a cloud of vinyl vapor to disperse before the eductor could be turned on again. Personnel dosimeter data showed
28.64 ppm vinyl exposure for this operation.
Leaks around the end of the braided hose sample line * caused high total hydrocarbon readings in the
breathing zone, up to 500 ppm. Hydrocarbon readings at the leak source exceeded 1.0%. Personnel dosi meter result for this operation was 56.99.
High hydrocarbon readings were obtained around the valve packings for the the unit even though recent maintenance had been performed on the packings. Readings in the breathing zone remained below 20 ppm. Personnel dosimeter result- for this operation was 0.99 ppm.
No area grid surveys were attempted during the loading due to shortage of time. Two personnel dosimeter testings were completed on the personnel in the dock shack. Results showed very little exposure 0.29 and
0.0 ppm.
CCR 000082134
PAGE 2
SUMMARY OF RESULTS
FINISH CARGO SAMPLING
HOSE DISCONNECT
and FIANGE INSERTION
High total hydrocarbon readings were obtained at the
leak on the braided hoses sampling line. Readings in the breathing zone generally remained below 20 ppm. Personnel dosimeter result showed 3.85 ppm vinyl
chloride exposure.
High total hydrocarbon readings were obtained in the
breathing zone while removing both the vent and
liquid loading lines aboard ship. The ship valves
leak badly and the eductor system could not remove
the fumes once the hoses v;ere disconnected. . Jtydro-
carbon readings range between 10 ppm and 1.0%, limit
of instrument readings, during this procedure.
Ifydrocarbon readings taken while inserting the flange
on the liquid line at dockside remained below 20 ppm
in the breathing zone. High readings, 1.0%, were of
found momentarily at -the connection once the line
was broken to insert the flange Personnel dosimeter
testing during these operation showed vexy high
results 326.77 ppm.
t
CCR 000082135
TABLE I
PERSONNEL EXPOSURE GAMMA. GAS LOADING 9-11,12
JOB
POSITION
TIME INTERVAL KR*
Bose Connection
Dockm&n
0.65
Flange Removal
Bookman
0.367
Heel Sample Qjrdroqulnone Addition Loading
Finish Cargo Sampling
Shift Foreman
Bookman
Bookman Bookman
Shift Foreman
0.833. 0.467
2.80 2.65
0.583
Bose Disconnect and
Flange Insertion
Dockzoan
. 1.03
TWA PIM VCM FROM DOSIMETERS
3.75
28.64 56.99 *
0.99 * 0.29 * 0.0 *
3.85 *
326.77 *
* Protected with fresh air equipment
cc OOOOQ2136