Document MGgjj8ydLVogZpK44xK6521Nk

FILE NAME Quigley QUIG DATE 1972 Dec 12 DOC QUIG034 DOCUMENT DESCRIPTION Industry Warning Information QUIGLEY COMPANY INC 238 E. 42ND ST NEW YORK N. 10017 OSHA AND ASBESTOS The following description is provided to acquaint users of asbestos based insulating materials with the latest OSHA Standards OSHA has determined that contact with asbestos fiber is a serious health hazard The standard states In view of the undisputed grave consequences from exposure to asbestos fibers it is essential that the exposure be regulated now on the basis of the best evidence available now even though it may not be as good as scientifically desirable An asbestos standard can be reevaluated in light of the results of ongoing studies and future studies but cannot wait for them Lives of employees are at stake The above paragraph in essence sets the tone of the entire for asbestos In fact OSHA considers asbestos a serious to have a separate section devoted to it OSHA standard enough material The particular section covering asbestos Contaminants Section 1910 93 is 1910. under Air Borne The threshold limit valve TLV for asbestos on an hour time weighted average is no more than 5 fibers longer than 5 micometers per cubic centimeter of air To measure if the TLV is exceeded samples shall be collected within the breathing zone of the employees on a membrane filter of 0.8 micrometer porosity mounted on an open filter holder Determination of the asbestos level is made at a magnification of 400-450 with phase contrast illumination We are not very far into the standard and already terms are being encountered which will create confusion as to what is being said In essence the standard is saying not to use asbestos based materials If you decided to use asbestos based materials the possibility of exceeding the TLV is so probable that the appropriate precautions have to be taken The precautions are as follows a All hand operated and power operated tools which may release asbestos | cutting insulating block shall be provided with local exhaust ventilation systems which will maintain the concentration below the TLV 24 09 0994 b Insofar as practicable asbestos shall be handled mixed applied removed cut scored or otherwise worked in a wet state sufficient to prevent emmission of airborne particles c No asbestos cement mortar coating grout plaster or similar material containing asbestos shall be removed from bags cartons or other containers without being either wetted or enclosed or ventilated to prevent release of airborne asbestos fibers The three sections above although making compliance somewhat awkward do not create a condition which is impossible to work However the next must section in our opinion is the key feature of the standard and probably creates the greatest frustration to users The assumption is that whatever asbestos based insulation goes on eventually come off and with that in mind the following section governs Spraying demolition or removal - Employees engaged in the spraying of asbestos the removal or demolition of pipes structures or equipment covered or insulated with asbestos and in the removal or demolition of as- bestos insulation or coverings shall be provided with respiratory equipment in accordance with paragraph d 2 iii of this section and with clothing in accordance with paragraph d 3 of this section special What this section has done in effect has discarded the TLV of 5 fibers per cubic centimeter completely and has directed the user to use certain respiratory equipment and clothing In simple terms the respiratory equipment referred to is a supplied respirator either continous or pressure demand type These types of respirators have an external source of air breathes The external source is either from a pressure which the employee tank or via air * hoses to the respirator The special clothing includes coveralls head cover- ing gloves and foot covering The employer shall provide 2 separate lockers or containers for each employee to isolate the contaminated clothing Launder- ing of contaminated clothing shall be done to prevent the release of airborne asbestos fibers If laundering is to be done by others the clothing shall be conveyed to the launderer in sealed impermeable containers and informed the clothing is contaminated with asbestos fibers In addition to the above other items in the standard state a Posting of caution signs in areas where asbestos is being used b Waste disposal in sealed containers c Exposure records on each employee d Employees to have reasonable access to any record required to be maintained e Notice to employee in writing if he has been exposed to airborne concen- trations of asbestos in excess of the limits prescribed 09 0995 The standard considers asbestos as a hazardous material and if a company is to use it it has to comply with some very strict regulations As noted some of these regulations are so restrictive that it creates extreme difficulty as well as delays in completing projects A number of users have decided not to use asbestos based materials and have started using Quigley's asbestos PANELEX insulation PANELEX has been specifically formulated without asbestos to meet OSHA standards PANELEX was introduced to the market in February of 1972 and has proven to be a high quality easy to use insulation It is available as a castable trowel and spray mix block and special shapes 12/12/72 09 0996