Document MGXkVaX7XQX3v8QpZRbLXXKjL
ABD00263751
V
4
R. E. Polk and C. J. McDonald
Interoffice Communication
From: Date:
Subject:
T. M. Haley November 10, 1989
WASTE VCM ADSORPTION
A
VISTA
Presently VCM Stack Emission from the Aberdeen PVC Plant are among the highest in the S-PVC industry. An Activated Carbon Adsorption System, as a replacement to External Steam Stripping, would place Vista's VCM Stack Emissions in the middle of the pack for S-PVC plants.
The preliminary design for the Waste VCM Adsorption Project is being issued for estimation. Currently, VCM Stack Emissions are about 180 #VCM/day. An Activated Carbon Adsorption System could lower VCM Stack Emissions to approximately 25 #VCM/day.
ZodLciL ffl. tffadUAy,
Todd M. Haley V Co-op Process Engineer
/tjs
cc: RWS, DCS - Summary Only PJK, RBN, SCH EJM, PCS - Houston