Document MG8oyroZpzbzkx8a2QGrdRXQ7
80
Air Conditioning
f5 AIR CONDITIONING CORP.
Manufacturers of Air Cooled Fandaire Air Conditionert dt Condensers
1815 South Maybelle Tulsa, Oklahoma CHerry 2-9266
Beprutaiataa and DiOributm t Principal Citie
FANDAIRE AIR COOLED CONDENSERS
Available in through 80 ton capacity
Conservatively rated, these condensers can be used on any application . . . either for new installation or as a replacement for outmoded equipment. While designed for outside installa tion, they work equally well inside. Their unique circular coil design delivers far greater operating efficiency than rectangu lar ' units. As standard equipment they incorporate many features normally sold as "extras."
Fandaire condensers above are the 3 and 80 ton units
FANDAIRE AIR COOLED
AIR CONDITIONERS
Available in through 10 ton capacity
Fandaire air cooled air conditioners are very good for com mercial, residential and industrial installation. The unique circular coil construction delivers far greater operating efficiencyth&n rectangular units. They can easily be <r>TT>h;,,^ with existing heating systems. Fandaire advanced design in corporates, without extra charge, many features normally sold as "extras." Available with a full five year warranty.
FANDAIRE FEATURES
on both the air conditioning and condenser units
GREATER FIN SURFACE EFFICIENCY
The fins are helically formed around a
heavy-wall eopper tube with a spacing of
eight fins per inch to permit the free pas sage of lint and dust carrying air. This self-cleaning action helps maintain
higher operating efficiency. The shoulder of eaceh on is firmm'ly swaged to the tube and to the ad"' jo`ini`*ng_ fin. 'N*o f`oreiggn matter or corrosion can form between the
tube and the shoulder to cause loss of heat transfer even after years of ex posure to the elements. In addition, the
shoulder provides a full 10Q percent con
tact with the tube, guaranteeing the maximum amount of beat will be trans
ferred to the fin. The fins are pyramidal
in shape for sturdiness and to permit the best possible dissipation of the heat.
TRUE COUNTER FLOW True counter flow is an action in which
the hot refrigerant is gradually cooled by Sowing against (or counter to) the
cooling medium. In other words, the refrigerant flows hot to cool, or counter
to the cooling medium whicn flows cool to hot. In Fandaire units, the hot gas
enters the condenser tubes at the inlet
header inside the condenser and makes m five complete circles before leaving the p tube at toe outlet header. Since the cool
air enters the condenser around the
periphery of the coil and is pulled through the bank of tubes, the coolest
gas is always in closest contact with the
tubes carrying the coolest gas. This pro vides the best possible counterflow and assures a greater mean temperature at
all times, giving a higher rate of heat
transfer, lower condensing temperature mH a greater degree of sub-cooling.
POSITIVE CONDENSATE DRAINAGE
Each row or layer of tubes slopes down
ward at a 30 deg angle. This means the tubes at the outlet header are lower than
the tubes at the inlet header. This slope assures a better drainage of all* conden
sate as fast as it forms on the tube wall. No pockets of compressor oil can form to
act as an insulator between the hot gas
and the air cooled tube walls.
STRAIGHT THROUGH FLOW
Each circuit consists of one continuous length of a single tube which completely eliminates ALL pressure drop caused by return bends. Laboratory tests have shown that up to 60 percent of the pres sure drop normally found in rectangular units is due to the short radius return bends necessary in their construction. Fandaire's long-sweeping, one-circuit construction approaches the almost non existent pressure drop of a single pass unit while retaining all the advantages of a five-pass unit.
VERTICAL AIR DISCHARGE
Vertical air discharge is part of the standard construction. -No air scoop or wind deflector is necessary. This vertical air discharge eliminates any tendency to re-circulate hot air and is a "must" in multiple installations. With Fandaire units there are no dead spots to be found on the face of the coil since the air is drawn around the circumference of the coil. Wind from any direction can be used, it is not necessary to face the units in the direction of the prevailing wind.
HOUSING
All Fandaire models are weatherproof. They are housed in attractive, corrosion resistant housings of a spun construction. Models up to 7H ton are made of alumi num alloy--all other models are gal vanized after construction for a durable, maintenance free finish. The air condi tioners are supplied with a two-piece, wrap-around skirt. Many other features, normally sold as "extras" on other units, are incorporated in the standard Fandaire design. These include legs, mount ing brackets, fan guards.
MOTORS AND FANS
Either direct drive or belt drive weather proof or totally enclosed, ball bearing, permanently lubricated motors are used on all Fandaire models. Fans are axial flow type and are constructed from plated, heavy-duty corrosion-resistant steel or aluminum.
Air Conditioning
>81
Allied (jiemical
GENERAL CHEMICAL DIVISION
40 Rector Street, New York 6, N. Y.
genetroriManufacturer of
Super-Dry Refrigerants
"Genetron" 12--White Label-- CCLFs--Diehlorodifluoromethime; and "Genelron" 22 Green label--CHGFi -----|WnnivlilnmHiflnnmmrttlnj. Used i& virtually all types of refrigeratiooand airconditioning equipment, large and small, household and industrial, direct and in direct expansion systems.
Typical units in which "Genetron" 12 and 22 are used: refrigerators, freezers.
frozen food lockers, window air con ditioners, home or office console - units, large custom-built units-for commerical comfort or industrial process, large store units, mobile units for transportation equipment, large home unite for addition to present hot air heating systems.
"Gcaelron" 11--Orange Label-- CCIfF--Triehlnromonoflnoromethane.
SELECTED PHYSICAL DATA
Dejected Physical Dot* (Performance based on 5*F evaporator temperature and 89*F
coadsiaer temperature) Cbemiea! Formula
Molecular Weight ` '
Pt. (*F) at I Atm. Pres sure
Evaporator Pressure at 5*F (paw)
Condensing Pressure at IFF (psiz)
Freezing Point (*F) at 1 Atm.
nn 11
CCLF 187.4 74.7
84.0*
1.5
-188
geaetroe 18
CClzFi 180.9 -81.0 .
11.8 93.8
-3S3
geaeWon
CHClFt 88.5
-41.4
88.8 158.8
-856
gaarfroo
CtCLFi 187.4 ' 117.6
87.9* 18.9*
-31
geaetnm
CiCliFr 170.9 87.6
15.4* 88.7
-76 '
For industrial and commercial refrigera tion and air-conditioning systems using single or multi-stage centrifugal compres sors. Can also be used for either direct or indirect expansion-type systems.
"Cenetron" 113--Purple Label CjCLFi--Trichlorotrifluororthxne. Used in 50-ton and larger centrifugal compres sors, primarily for large comfort cooling systems, brine cooling systems and other commercial and industrial air condition ing and refrigeration systems.
"Genctron** 114a--Blue Label-- C*C1iF4--Diehlorotetraflnoroethane. Used in centrifugal and rotary compres sors for commercial, industrial and house hold refrigeration.
QUICK FACTS on "Genetron" SoperDry Refrigerants:
Critical Temperature (*F) Critical Pressure (psi absolute) Compressor Discharge Tempers-
Compression Ratio (85*F/5*F)
Sporifio Volume
Saturated
Vapor at 6*F (eu ft/lb)
latent Best at Vaporization at 5*F (Btu/lb)
Net Refrig. Effect of Liquid-- *F/5*F (Btu/lb)
Bpeeifie Heat of liquid at B8*F (Btu/lb*F)
S8*FSpecific Heat of Vapor at Con stant Pnasure of I Atm. A (Bto/lb*F)
Specific Heat Ratio at 85*7 A 1 Atm. (k - Cp/Cv)
Coefficient of Pcrformaiwe
Hcraspover/Ton Refrigeration
Refrigerant Circulated/Ton Re frig. (Ibn/miu.)
Liquid Ctrculated/Tan Refrig, (cu in/mm.)
Compressor Dtaplaoemeat/Toa Retrig, (cfm)
Toxiritjr (Underwriters' Labora tories Group No.)
Ttamnubility A Rrplcajvity
SS8 685 118
8.84 18.87 84.0 07.8 0.81` 0.18
1.14 5.09 0.987 8.90 50.0 88.88
SA None
884 697
101
4.08 1.46
68.8
50.0
0.84
0.15
805 715 181
4.06 1.85
98.0
63.S
- 0.84
Q.t6
1.14 4.70 1.003 4.00 85.0
5.83 6 Noae
1.15 4.05 1.011 8.89 68.0 8.60 SA Nona
417 495 86
8.03 >7.04 70.6 58.7 0.18 0.15
1.08 4.98 0.960 3.78 66.6 tOO.76 4-6 Noae
394 478 88
5,83 4.01 60.3 43.0 0.83 0.10
1.01 4.00 1.025 4.45 68.7 18.78 4 None
Guaranteed exceptionally low moisture content
Non-corrosive to standard equipment materials .
Non-toxic, non-flammable, stable, safe
Critical and freezing points well outside range of operating uses
Solvent action on oil helps prevent solidi fication or congealing of lubricant
Freely interchangeable and may be mixed in any proportions with com parable fluorinated hydrocarbons meeting the same strict refrigerant specifications
Aid in lubrication of equipment; gener ally miscible with oil
Available everywhere from refrigeration wholesalers throughout the country