INTERNAL CORRESPONDENCE
CHEMICALS AND PLASTICS
*
>.vi.cn .ncatit.",
Zcpy to
Mr. W. T. Shelton 704 Shop
Mr. G. F. Hurley Mr. G. C. Merz Mr. M. E. Perry Mr. H. L. Robinson
P. O. BOX 8361, SOUTH CHARLESTON, WEST VIRGINIA 25303
0a1e November 27, 1978 oep.. Technical Center IH/EP
Syb Asbestos - Stripping Old Insulation
PROJECT
Survey for asbestos exposure of insulator
stripping insulation from Dowtherm lines in
Building 707, Cell 3.
SUMMARY
Good work practices and proper housekeeping
by insulators kept the exposure to asbestos
fibers at a minimum. Less than 0.20 fibers/cc > 5 pm - TWA
for eight hours. The insulation was wet down with a water hose
and the dismantled material was labeled and bagged for disposal
at the landfill.
DISCUSSION
A large stripping job of old insulation con
taining asbestos fiber was started on November 16,
1978, in Cell 3 of Building 707. The lines serviced a Dowtherm
heater and ran through three levels of the cell floor. To
facilitate the removal of this insulation containing asbestos, it
was recommended that the piping be removed with the insulation
intact and stripped at the Insulators' Shop. To remove the pipe,
flanges and couplings had to be stripped of insulation for the
pipefitters and riggers to unbolt and remove the lines from the
cell.
Mr. R. Raines, an insulator (wearing an organic vapor respir ator), made the necessary openings in the insulation for removal. The insulation was wet down before cutting and the stripped mate rial was bagged and labeled for disposal.
When the lines are dismantled and removed from the cell and transported to the shop area, additional personal and area samples
UCC 024355
2
of the ambient air will be collected and analyzed for asbestos. The exposure was well below the TWA of 2 fibers/cc and a ceiling value of 10 fibers/cc.
RESULTS
DATE 11/16/78
PERSONNEL TIME-MIN-LITERS/AIR
R. Raines* 1252-1345 = 53/95.4
11/16/78 R. Raines* 1345-1425 = 40/72
TWA = 1,05 x 93 = 0.20 fibers/cc >5 pm 480
EXPOSURE FIBERS/CC >5 urn
0.44
0.61
Willson 122510 Half-face respirator.
REFERENCES
Volume 38C-29X4-Rla Asbestos Dust Determina
tion by Membrane Filter Technique Using Phase
Contrast Microscopy.
REPORT PREPARED BY
G. W. Bott Technical Center Industrial
Hygiene Department
GWB/sc
G. W. Bott
UCC 024356
sampling data TV'PE
8Z - BREATHING ZONE P . PERMANENT STATION 0 OPERATIONAL TASK A . AMBIENT S SOURCE
METHOD CTCAR30N TUBE Mi MIDGET iMPINGER FC - FILTER CASSETTE 0- GRAS DT DETECTOR TUBE CRI - DIRECT READING INSTRUMENT
RATE UNIT CCM CC PER MINUTE ..PM - 1 ITERS PER MINUTE C:M-CUBIC FEET PER MINUTE
VOLUME UNIT CC CUBIC CENTIMETERS L - LITERS CF CUBIC FEET
ANALYTICAL DATA UN'T
. g - MiCROGRAMS ,nc - M LL.GRAMS
EQUIPMENT IDENTIFICATION
GLOSSARY
ANALYTICAL DATA CONTD. AIR CONCENTRATION IN UNIT
PPM - PARTS PER MILLION (BY VOL.l mg. M- MiLLIGRAMS PER CUBIC METER F CC - FIBERS PER CUBIC CENTIMETER MPf CF - MILLION PARTICLES PER CUBIC FOOT
METHOD GC GAS CHROMATOGRAPHY |R INFRA RED SPECTROPHOTOMETRY UV . ULTRAVIOLET SP - ViSLIAL SPECTROPHOTOMETRY AA - ATOMIC ABSORPTION SPEC. GV - GRAVIMETRIC ANALYSIS MIC - MICROSCOPY
PERSONNEL DATA PROTECTION USED
F5 FACE SH'ELD &C - BARRIER CREAM
5 BOOTS RESP - RESPIRATOR PROTECTION GLV.GLOVES CLTH PROTECTIVE CLOTHING