Document MDjqozEo4j2d5qVYXjbnm7dk
INTERNAL CORRESPONDENCE
GA 1076
FROM
R. T. Cheng
TO R. L. Gibson, M.D./H. E. Runion
SUBJECT PRESENTATION RE: INDUSTRIAL HYGIENE CONCERNS OF GOCHEM ASIA OPERATIONS '
IN REPLY
refer to RTC:80-17
date Feb. 22, 1980
Attached is a rough draft of the Presentation To Mr. Roher on the Industrial Hygiene Concerns Of GOCHEM Asia Operations.
Mr. John Strausser requested me to mail him two copies of all viewgraphs and handouts before the actual presentation. I think we should discuss this package Tuesday or Wednesday (February 26th or 27th) before mailing it in the final form to Mr. Strausser.
The major uncertainties In this presentation is our (Medical Department) recommendation on VCM standard, cost estimates, and our future involvement in GOCHEM ASIA.
RTC:vic Attachment
R. T. Cheng
CUSAROSS 00893
PRESENTATION TO
MR. W. C. ROHER INDUSTRIAL HYGIENE CONCERNS OF
GOCHEM ASIA OPERATIONS
CUSAROSS 00894
A
HIGHWAY r
STORAGE
FILM PLANT
LEATHER PLANT
<3 M^ 1z--<z: QCC.
MASTER BATCH
SCRAP
TILE PLANT
ADM SHOP
MONOMER FI PLANT \J
\
POLY PLANT
MERCURY CELLS
CHLOR-ALKALI PLANT
CARBIDE PLANT
EXTRUSION
PIPE PLANT
CHINA GULF PLASTICS CORPORATION TOUFEN PLANT
CUSAROSS 00895
VCM EXPOSURES STANDARDS
1. U. S. OSHA STANDARD
1 PPM
2. SWEDEN STANDARD:
1 PPM
3. JAPANESE STANDARD:
2 PPM
4. TAIWAN STANDARD:
500 PPM in 1977 50 PPM NOW
5. CGPC INTERNAL STANDARD: 10 PPM
6. GULF RECOMMENDED:
(--)
ODOR THRESHOLD:
2,000 PPM
CUSAROSS 008%
HISTORICAL REVIEW OF VCM EXPOSURES AT CGPC
February 1974: August 1976: November 1977: October 1979:
.1 VCM ODOR READILY SENSED
2. 200 PPM TO 500 PPM TWA EXPOSURE 3. SHORT-TERM EXPOSURES >10,000 PPM
.1 VCM ODOR STILL DETECTABLE
2. >50 PPM TWA EXPOSURE
1. VCM ODOR ESSENTIALLY ELIMINATED 2. REACTOR CLEANER'S EXPOSURE 15-50 PPM 3. OTHER POLYMER PLANT WORKER <10 PPM
1. VCM ODOR ELIMINATED 2. REACTOR CLEANER'S EXPOSURE 18 PPM 3. OTHER POLYMER PLANT WORKER 1 - 33 PPM
CUSAROSS 00897
TABLE II REACTOR CLEANERS' VINYL CHLORIDE EXPOSURE
CHINA GULF PLASTICS CORPORATION
REACTOR CLEANER Chen, C. S. Chuang, C. C.
Tan, C. K. Chuang, C. C. Tan, C. K. Lai, T. Z. Chen, C. S. Lai, T. Z.
Chuang, C. c. Chuang, C. c.
Lai, T. Z. Chen, C. S,
EMPLOYEE NUMBER 64114 60117 66124 60117 66124 67217 6414 67217 60117 60117 67217 64114
SAMPLE DATE
10-16-79 10-16-79 10-16-79 10-17-79 10-17-79 10-17-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79
SAMPLE DURATION (MINUTES)
423 415 405 442 442 442
46 44 43 45 45 45
AVERAGE VCM EXPOSURE PPM 12 16
23 20 23 18 16 22 17 18 17 18
REMARKS Cleaned 6 Reactors Cleaned 6 Reactors Cleaned 6 Reactors Cleaned 6 Reactors Cleaned 6 Reactors Cleaned 6 Reactors Cleaned 1 Reactor Cleaned 1 Reactor Cleaned 1 Reactor Cleaned 1 Reactor Cleaned 1 Reactor Cleaned 1 Reactor
Sample Matrix
- Charcoal Tube and 3M Brand Organic Vapor Monitoring Badge.
Analytical Method = GC & FID
11 CUSAROSS 00898
CGPC VCM AIR POLLUTION
EPA VCM EMISION STANDARD TAIWAN EMISSION STANDARD: CGPC IN-PLANT POLLUTION: CGPC HOUSING COMPOUNDS: SURROUNDING COMMUNITY:
10 PPM IN STACK OR EMISSION SOURCES NONE
0 TO 2 PPM
0 TO 0.5 PPM VCM
0 TO 0.5 PPM
CUSAROSS 00899
TABLE IV ENVIRONMENTAL AND WORKPLACE VINYL CHLORIDE CONCENTRATIONS AT TOUFEN PLANT
CHINA GULF PLASTICS CORPORATION October 19, 1979
SAMPLE NUMBER AG7492
AG7072 AG7289 AG9331 AH5605 AH5149 AG7313 AH5128 AG7370 AG7055 AG7112 AG7407
SAMPLE LOCATION Office, Engineering and Develop ment Building South of Administration Building South of HCL Plant South of Maintenance Shop West of Printing Plant 2nd Power Station Office Room, Chemical Plant Booth at Monomer Plant Office Room, Polymer Plant PVC Package, Drying Plant Control Room, Drying Plant Polymerization Pilot Plant
SAMPLE DURATION (MINUTES)
457
436 448 423 420 417 412 408 402 394 392 397
AVERAGE VCM CONCENTRATION
PPM 2.6
0.44 0.41 0.94 0.53 15 2.1 2.2 2.7 0.87 1.4 . 5.0
Sample Matrix
= 3M Brand Organic Vapor Monitoring Badges.
Analytical Method = GC & FID.
ClfSARO.SS ()09()t 14
TABLE V
VINYL CHLORIDE EXPOSURES OF FABRICATION COMPLEX WORKERS DUE TO INPLANT VCM AIR POLLUTION
CHINA GULF PLASTICS CORPORATION
SAMPLE DATE
10-16-79 10-16-79 10-16-79 10-16-79 10-16-79 10-16-79
10-17-79 10-17-79 10-17-79 10-17-79 10-17-79 10-17-79 10-17-79
10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79 10-18-79
10-11-79 10-11-79 10-11-79 10-11-79
WORKER
Liu, S. L. Chen, Y. K. Chai, C. S. Chen, 0. S. Lin, Z. S. Chang, S. S.
Chen, Y. K. Peng, W. C. Chai, C. S. Huang, W. H. Wu, C. Y. Liu, S. L. Lee, K. J.
Chuang, M. L. Chang, Y. H. Chang, S. S. Lien, Y. C. Liao, W. H. Tong, S. L. Ko, C. F. Chai, F. L. Lin, Z. S. Chen, J. S. Hsu, Y. K.
Lee Tzung Feng Liu
JOB LOCATION
Leather Plant Leather Plant Leather Plant
Film Plant Printing Plant Printing Plant
- Toufen - Toufen - Toufen - Toufen - Toufen - Toufen
Leather Plant Leather Plant Leather Plant Leather Plant Leather Plant Leather Plant Leather Plant
- Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen
Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant Printing Plant
- Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen - Toufen
Printing Plant - Taoyuan Printing Plant - Taoyuan Printing Plant - Taoyuan Printing Plant - Taoyuan
AVERAGE VCM EXPOSURE PPM
0.54 0.49 0.49 0.53 0.54
ND ND ND ND ND 0.03 0.20
0.12 0.12 0.15 0.15 0.12 0.15 0.18 0.15 0.15 0.18 0.12
ND ND ND ND
Sample Matrix
= 3M Brand Organic Vapor Monitoring Badge.
Analytical Method = GC & FID.
ND = Not Detected; Less Than 0.01 ppm.
16 CUSAROSS 00901
W/M>
S_ _
/*
2,ppr
# 0 ppm
11 0*5
fpr *
*i 2JP,t1 '
\
POLY
*
l5pr~
# o.if-
MERCURY
U'ATHZR
pi a ,/r
0.5
IfJ-Pif\UT VCM A/P POLLdT/Od AT C$PC TDUFEP PLAPT
CUSAROSS 00902
CGPC VCM CONTROL RECOMMENDATIONS
1. A THREE-STEP VCM EXPOSURE CONTROL PROGRAM WAS RECOMMENDED IN 1976 (SEE HANDOUT). STEP ONE: < 2,000 PPM, STEP TWO: 10 PPM, STEP THREE: 1 PPM.
2. STEP ONE ACHIEVED. 3. STEP TWO CAN BE ACHIEVED WITH REDUCTION OF
REACTOR CLEANING FREQUENCY. 4. STEP THREE CAN BE ACHIEVED BY ADOPTING AN
AUTOMATED REACTOR CLEANING SYSTEM TO ELIM INATE ROUTINE REACTOR ENTRY. 5. IN-PLANT VCM AIR POLLUTION PROBLEM WILL BE MORE OR LESS UNDER CONTROL WHEN STEP THREE IS ACHIEVED. 6. COSTS:
CUSAROSS 00903
CGPC MERCURY EXPOSURE
EXPOSURE STANDARD FEBRUARY 1974 LEVEL AUGUST 1976 LEVEL NOVEMBER 1979 LEVEL
0.05 mg/m3 0.25 mg/m3 0.05 mg/m3 0,02 mg/m3
ALL CHLOR-ALKALI PLANT WORKERS WERE WITHIN MERCURY EXPOSURE STANDARD EXCEPT THE TWO DOWNSTAIRS OPERATIONS:
1. FLAKE CAUSTIC-SODA MACHINE OPERATOR: 0.13 mg/m3
2. MERCURY RECOVERY OPERATOR:
0.10 mg/m3
RECOMMENDATIONS 1. MOVE THE CAUSTIC-SODA MACHINE OUT OF DOWNSTAIRS. 2. RESPIRATORY PROTECTION FOR UN-ROUTINE OPERATION.
COSTS: $5,000
CUSAROSS 00904
CGPC SOLVENTS EXPOSURE
SOLVENTS USED:
MEK, TOLUENE, (BENZENE), MIBK, CYCLOHEXANONE, DMF, THF, etc.
SOLVENT USERS:
SURFACE TREATING MACHINES COLOR PRINTERS
EXPOSURE STANDARD:
MEK - 200 PPM TOLUENE - 100 PPM BENZENE - 10 OR 1 PPM
EXPOSURES OF SURFACE TREATING MACHINE OPERATORS
1974: 1976: 1979: CONCLUSION:
1,000 PPM 200 - 500 PPM 50 - 200 PPM NEEDS SOME IMPROVEMENT
EXPOSURES OF COLOR PRINTER OPERATORS
1974:
500 - 1,500 PPM
1976:
200 - 500 PPM
1979:
<50 PPM
CONCLUSION: PROBLEM UNDER CONTROL
CUSARO.S.S 00905
CGPC DUST EXPOSURES
STABILIZERS: LEAD, CADMIUM, BARIUM STEARATES
PIGMENTS:
LEAD, CHROMIUM, CADMIUM, ORGANIC DYES
PVC DUST:
NEW TOXICOLOGIC STATUS EXCESSIVE PNEUMOCONIOSIS FED REGISTER NOTICE (December 18, 1979)
EXPOSURE STANDARDS
LEAD:
0.05 mg/m3
CADMIUM: 0.05 mg/m3
BARIUM:
0.5 mg/m3
CHROMIUM: 0.05 mg/m3
PVC DUST: Now
- 10 mg/m3
Future - 2 mg/m3 (?)
CGPC EXPOSURES MANY OVEREXPOSURES TO PVC DUST SOME OVEREXPOSURES TO LEAD ONE OR TWO OVEREXPOSURES TO CHROMIUM
RECOMMENDATION: ENCLOSURE, VENTILATION, HOUSEKEEPING
COSTS: $100,000
CUSAROSS 00906
A/30/74
-31-
RTC
Figure 12
Suggested Side-Draft Hood for Control of Lead, Cadmium & Barium Dusts,
CUSAROSS 00907
ASIA POLYMER CORPORATION
8RAND NEW PLANT
MANUFACTURING:
LOW DENSITY POLYETHYLENE
MAJOR HEALTH HAZARD: N-HEXANE
MINOR PROBLEMS:
LAB VENTILATION, NOISE
N-HEXANE:
NEUROPATHY
OLD STANDARD
500 PPM (1972)
EXISTING STANDARD 100 PPM
CHANGE INTENDED 25 PPM
APC CATALYST WORKER'S EXPOSURE: 43 AND 240 PPM
RECOMMENDATION
VENTILATION IMPROVEMENT OF CATALYST MIXING BUILDING AND LABORATORY.
COSTS $1,000 - $5,000
CUSAROSS 00908
TAITA CHEMICAL COMPANY, LTD.
FORMALDEHYDE
EXISTING OSHA STANDARD:
3 PPM
NIOSH 1974 RECOMMENDATION: 1 PPM
CUT REPORT:
NASAL SQUAMOUS CELL CARCINOMAS IN RATS AT 15 PPM. A FEW AT 6 PPM AND 2 PPM LEVEL.
FUTURE STANDARD:
0.1 PPM - 1 PPM (?)
ODOR THRESHOLD:
0.1 PPM - 1 PPM
EXPOSURE LEVEL (SAMPLE)
LANDSDALE PLANT
0.3 PPM - 2 .5 PPM
RECOMMENDATIONS* *
* ENGINEERING INPUT AT ABS PLANT DURING CONSTRUCTION STAGE FOR AN CONTROL.
* SPI ESTIMATE $2.56 MILLION CAPITAL COSTS FOR A TYPICAL 62.5 MILLION LB/YR ABS PLANT TO MEET 2 PPM STANDARD.
* TAITA ABS PLANT 15,000 Mta, OR APPROXIMATELY 33 MILLION LB/YR, NEED $1.6 MILLION FOR CAPITAL COSTS BASED ON SPI FORMULA.
* INDUSTRIAL HYGIENE SURVEY OF ABS PLANT, FORMALDE HYDE PLANT, POLYSTYRENE PLANT, ETC.
CUSAROSS 00909
TAITA CHEMICAL COMPANY LTD.
NO INDUSTRIAL HYGIENE VISIT MANUFACTURING: POLYSTYRENE, FORMALDEHYDE, GLUES
PHENOLIC COMPOUNDS, ABS (1980)
ACRYLONITILE (AN): CARCINOGEN, TERATOGEN* * OSHA STANDARD (OCTOBER 1978): 2 PPM TWA 10 PPM CEILING * DU PONT, GOODYEAR, MONSANTO, DOW INDICATED THE STANDARD IS ACHIEVEABLE, WITH FEW EXCEPTIONS, THROUGH EXHAUST VENTILATION, PROCESS CONTAIN MENT AND CHANGES IN JOB PROCEDURES * AN EXPOSURES DURING ABS MANUFACTURING 1. CONVEYANCE OF AN MONOMER TO AND FROM STORAGE TANK. 2. LEAKS FROM VALVES, GASKETS, PIPES AND SAMP LING POINTS. 3. BLENDING, FLOCCULATION, DRYING. 4. RESIDUAL AN DURING POLYMER PROCESSING. 5. REPORTED TYPICAL HIGH EXPOSURES: 20 PPM AT FLOCCULATION.
CUS A ROSS 00910
CHINHAE CHEMICAL COMPANY
MANUFACTURING:
UREA, COMPLEX FERTILIZER, GYPSUM, SULFURIC ACID
MAJOR HEALTH HAZARDS: AMMONIA, FLUORIDES, FREE SILICA
MINOR PROBLEMS:
HYDROGEN FLUORIDE, WELDING FUMES
AMONIA EXPOSURE
EXPOSURE STANDARD: 25 PPM TWA, 35 PPM CEILING
MEASURED LEVELS:
5 PPM IN GRANULATION CONTROL ROOM >100 PPM AT GRANULATION TOWER
CUSAROSS 00911
CHINHAE CHEMICAL COMPANY
DUST EXPOSURE FREE SILICA CONTENT OF DUST -v 4% DUST EXPOSURE STANDARD **4.3 mg/ 3 DUST OVEREXPOSURE: 6 OUT OF 13 SAMPLES RESPIRATORS WORN BY WORKERS IN DUSTY OPERATIONS.
FLUORIDE EXPOSURE * USE OF RESPIRATOR PREVENTS MOST OVEREXPOSURE * URINE FLUORIDE LEVEL AS INDICATION OF FLUORIDE EXPOSURE * 4 OUT OF 46 WORKERS SHOWED POSSIBLE WORKRELATED FLUORIDE OVEREXPOSURE
RECOMMENDATIONS * COMPREHENSIVE VENTILATION ENGINEERING STUDY * SEARCH AND SECURE LEAKS * INDUSTRIAL HYGIENE TRAINING
CUSAROSS 00912
GOCHEM ASIA OPERATION INDUSTRIAL HYGIENE PERSONNEL TRAINING TRAINING PROGRAM ' NIOSH TRAINING COURSES * GULF IN-HOUSE TRAINING ' ON-THE-JOB TRAINING TRAINEES . TWO FROM KOREA OIL CORPORATION (SEE SCHOEBERLEIN'S LETTER OF ACCEPTANCE) * ONE FROM CHINHAE CHEMICAL COMPANY, LTD. * ONE OR TWO FROM TAIWAN OPERATION (SEE MR. GAMBRILL'S LETTER)
CUSAROSS 00913