Document MDZJzYVveXvp7kp67kdoqm69
LSASD Project ID: 24-0149
McComb POTW NPDES Compliance Evaluation Inspection
Location: 1052 Southyard Road McComb, MS
Project Date: March 5th, 2024
Report Date: April 4th, 2024
LSASDFORM-066-R2 052923
Project Leader: Chris McHugh Water Quality Section Field Services Branch Laboratory Services & Applied Science Division USEPA - Region 4 980 College Station Road Athens, Georgia 30605-2720
The ANSI National Accreditation Board attests that U.S. EPA Region 4 Laboratory Services and Applied Science Division fulfills the requirements of ISO/IEC 17025:2017 ANAB Forensic Testing & Calibration AR 3125:2019 in the field of Forensic Testing. The activities contained in this report fall within the scope of accreditation, Certificate Number: AT-2628. Expires 08 June 2024.
LSASD Project ID: 24-0149
Page 1 of 6
Final Report
LSASDFORM-066-R2 052923
Project Requestor:
Jairo Castillo, P.E., Section Chief Wastewater Enforcement Section Enforcement & Compliance Assurance Division USEPA - Region 4 61 Forsyth Street, SW Atlanta, GA 30303-8960
Analytical Support: Not Applicable
Approvals:
Digitally signed by CHRISTOPHER
CHRISTOPHER MCHUGH MCHUGH
Date: 2024.04.04 15:41:47 -04'00'
Chris McHugh Water Quality Section Field Services Branch
Approving Officials:
JOHN RUIZ
Digitally signed by JOHN RUIZ Date: 2024.04.03 13:11:22 -04'00'
John Ruiz, Technical Reviewer Water Quality Section Field Services Branch
Digitally signed by DEREK LITTLE Date: 2024.04.08 08:03:33 -04'00'
Derek Little, Acting Section Chief Field Services Branch
DENNIS SAYRE Date: 2024.04.04 11:23:20 -04'00' Digitally signed by DENNIS SAYRE
Jairo Castillo, P.E., Chief Wastewater Enforcement Section
LSASD Project ID: 24-0149
Page 2 of 6
Date
Date Date Date
Final Report
LSASDFORM-066-R2 052923
1. Introduction
On March 5th, 2024, the United States Environmental Protection Agency (EPA) Region 4, Laboratory Services and Applied Science Division (LSASD), conducted a National Pollutant Discharge Elimination System (NPDES) Compliance Evaluation Inspection (CEI) of McComb Publicly Owned Treatment Works (POTW) in McComb, MS. The facility is operated by Inframark for the City of McComb. The inspection was conducted under the authority of Section 308 of the Clean Water Act (CWA), as amended. This report presents the results of the inspection. The inspection followed the procedures listed in the LSASD Project No. 24 - 0149 Sample and Analysis Plan (SAP). Table 1 lists the sampling participants and facility staff.
Table 1 - Inspection Personnel
Name Chris McHugh
Asher Sampong Justin Berry Jackson Dear
Eddy Russell
Organization EPA Region 4 LSASD Inspection EPA Region 4 LSASD Inspection MDEQ Jackson MDEQ Jackson Inframark/ facility
manager
Date on Site 03/05/24
03/05/24 03/05/24 03/05/24 03/05/24
Contact Info mchugh.christopher@epa.gov
sampong.asher@epa.gov JBerry@mdeq.ms.gov jdear@mdeq.ms.gov
eddy.russell@inframark.com
2. Inspection Procedures
The objective of this inspection was to evaluate the condition of the water pollution control plant and the permittee's self-monitoring program and offer compliance assistance as needed. Specific tasks included conducting an opening conference, interview facility staff, conducting a facility walkthrough, conducting records review, observing the receiving waters, and a closing conference.
3. Facility Description
McComb POTW (Figure 1) uses an activated sludge process called vertical loop reactor (VLR) with covered diffused mechanical aerators (Figure 2). The influent headworks consisted of screw pumps, automated bar screens, one manual bar screen and grit removal cyclones. There are plans to upgrade the headworks in the next year according to the operator. There is an eight-bank ultraviolet disinfection system in operation before the final effluent discharge to the receiving stream.
LSASD Project ID: 24-0149
Page 3 of 6
Final Report
LSASDFORM-066-R2 052923
Figure 1. - McComb POTW Site Layout
LSASD Project ID: 24-0149
Figure 2 - VLR Process Page 4 of 6
Final Report
LSASDFORM-066-R2 052923
4. NPDES Permit
The facility's National Pollutant Discharge Elimination (NPDES) permit number MS0061077, was issued (renewed) by the State of Mississippi on January 23rd, 2024, and expires on June 30, 2028. The NPDES permit allows the POTW to discharge an average of five million gallons per day (MGD) of treated wastewater into Town Creek through Outfall 001.
The permit includes effluent limits for Total Suspended Solids (TSS), 5-day Biochemical Oxygen Demand (BOD5), Phosphorous, pH, Dissolved Oxygen (DO), Ammonia Nitrogen, Total Nitrogen, and Fecal Coliform Bacteria. It also includes total Copper, Cyanide and Zinc limits.
5. Records and Reports
a. Online Discharge Monitoring Sheet Review
Below is a review of EPA's Integrated Compliance Information System database for the months of July 2021 through September 2023. Table 2 shows the summary of the facility's compliance history of the NPDES permit effluent limits.
Table 2 - DMR Permit Exceedances
Period
07/0109/30/21 10/0112/31/21
10/0112/31/22
07/0109/30/23
Parameter
Effluent BOD5 Effluent BOD5 Effluent, Total Nitrogen Total Copper
Permit Limit 10.95 mg/L 10.95 mg/L
2.19 mg/L
0.079 mg/L
Report Value
14.2 mg/L (30% exceedance)
15.4 mg/L (41% exceedance)
2.83 mg/L (29% exceedance)
0.01 mg/L (27% exceedance)
Statistical Basis Weekly Weekly
Quarterly
Quarterly
b. On-site Records Review
The facility maintains all its DMR and analytical records onsite and had at least 3 years of records available. There were some isolated instances of incomplete benchsheets for January 24 26th, 2024, where an analyst did not completely fill in every date line or initial line on a given sheet.
c. Flow Measurement
The effluent discharge is measured using an ultrasonic flow meter over a 3 ft Parshall flume. The flow meter was operational and was within 10% instantaneous flow rate of the primary Parshall Flume when checked with the Parshall Flume staff gage. It was last calibrated in April
LSASD Project ID: 24-0149
Page 5 of 6
Final Report
LSASDFORM-066-R2 052923
2023. The ultrasonic sensor should be placed in the middle of the channel instead of near the side wall to measure the flow level.
Figure 3 - Effluent Flow Meter
Figure 4 - Effluent Parshall Flume
d. Sampling Review
The facility collects and analyzes 24-hr composite samples for its permit listed parameters except total Phosphorus and total metals. Phosphorous and total metals are analyzed by Waypoint Analytical.
6. Operation and Maintenance
The facility is operating and maintaining its treatment units to meet its NPDES permit requirements.
7. Effluent and Receiving Waters
The effluent discharge was clear and free of any solids and foam in the receiving stream. 8. Discussions and Findings
The facility should consider additional quality control samples to ensure that the total metal permit exceedances are not because of sample contamination. The facility should also ensure that staff review laboratory record keeping practices to complete laboratory benchsheets accurately with proper documentation. The facility should have its contractor that maintains the flow measurement equipment review the placement of the ultrasonic flow meter to best monitor the flow level.
End of Report
LSASD Project ID: 24-0149
Page 6 of 6
Final Report