INTERNAL CORRESPONDENCE
I j!\JI(...)(\) |JAHBI[ )i I :I ;R( :GHAT!ON
A. F. Terry 704 511
P. D. Gossage - 701/4 C. P. Maxwell - 701/2 R. G. Rowe, M.D. - 791 C. L. Ruddle - 704 R. E. Sergent - 725 P. D. Sherman - 701/2
August 28, 1987
EM&TS - HS&EA
Industrial Hygiene
Asbestos Exposure Monitoring - 701
Attached are the results of the Asbestos exposure monitoring performed on two insulators, while stripping asbestos inside of a negative pressure enclosure, and two carpenters, while assisting with moving enclosures and the catch chute* The employees were monitored in Building 701 - 3rd floor and the basement on August 17, 18, 19, 20, and 21, 1987.
The insulators were equipped with 2 pair of coveralls with headcover, boots and respirators. (A description of the respirator worn on a given day can be found along with exposure results.) The carpenters were equipped with a pair of disposable coveralls and half-face HEPA cartridge respirators (see table for specific respirator).
The monitoring results indicate that the levels found on the insulators were well above the 0.2 fiber/cc Permissible Exposure Level (PEL), established by OSHA for an 8-hour workday (TWAg). However, they were adequately equipped with respirators. The samples collected on the carpenters were all well below the OSHA 0.1 fiber/cc Action Level. There were no 8-hour time weighted averages reported because these employees had worked with some asbestos insulation before the monitoring periods. Also, the sampling period was not adequate to calculate the TWAg.
The area samples collected on the 3rd floor and basement were well below the Action Level, which would indicate that the airborne fibers were contained inside of the negative pressure enclosure. A commendation is due to all employees involved in the work.
UCC 011360
IH Monitoring - continued
-2-
August 28, 1987
A source sample was collected inside of the enclosure after being exhausted for approx. 24 hours with a HEPA filtered vacuum cleaner. The sample was collected to determine if the airborne fibers were being adequately removed before moving the enclosure. The result showed that the levels were well below the Action Level.
Please notify all of the employees of their exposure monitoring results as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330.
If we can be of further assistance, please feel free to call us on extension 4779 or 3750.
WORK BY:
APPROVED BY:
VES:MAP:rab 2646P
Manhar A. Patel
UCC 011361
ASBESTOS EXPOSURE MMTCRING - 701
Carp. Ref. W2264
Date
Sanple Type/ Employee Name
Sanpling Time
Air Cdnc. fibers/x
TWAq fibers/x
Type of Respirator
Used
CCWENTS
8-17-87
1
8-17-87
8-17-87
8-17-87
Area
8-17-87
Area
2hrs 13nin 0.601
-
2hrs 9min
0.720
2hrs 7tain
0.0167
2hrs 6min
0.018
2hrs lOrrin ^0.0071
-
A0 R57A Half face HEPA cartridge
AO R57A Half face HEPA cartridge
Willson R12 Half-face HEPA cartridge
-
Collected while removing approx. 60 feet of asbestos from pipe chase between labs 301 and 303 inside of negative pressure enclosure.
Collected while removing approx. 60 feet of asbestos from pipe chase between labs 301 and 303 inside of negative pressure enclosure.
Collected while installing foam into pipe chase, moving enclosure and catch chute in basement.
Collected in the hallway halfway between Micro trap and the opening of the negative pressure enclosure.
Collected in basement under the chases where asbestos stripping took place.
8-18-87
Area
5hrs 28nin *10.002
8-18-87 8-18-87
Area -i
8-18-87
VOIDED - SAMPLER QUIT
Ihr 23min
2.197
-
Ihr 19nin
1.384
-
AO R57A Half face HEPA cartridge
AO R57A Half face HEPA cartridge
Ccnp. Ref. W2270
Collected in 3rd floor hallway between the two pipe chases being stripped - between labs 303 and 305.
Basement under pipe chases.
Collected while stripping asbesta from pipe chases between labs 303 and 305 - approx. 40 feet.
Collected while stripping asbesta from pipe chases between labs 303 and 305 - approx. 40 feet.
UCC 011362
ASBESTOS EXPOSURE MONITORING - 701 (continued)
Carp. Ref. W2271
Date
Sanple Type/ Enployee Name
Sanpling Time
Air Cone, fibers/cc
fibers/cc
Type of Respirator
Used
COM:NTS
8-19-87
8-19-87
Area
8-19-87 8-19-87
Area
8-19-87
2hrs 3tain
0.036
-
5hrs 25min 0.008
VOID - SAW'LER QUIT
Ihr 29min
1.0176
-
lhr 28nin
1.077
-
R12 Willson Half-face HEPA cartridge
-
AO R57A Half face HEPA cartridge AO R57A Half face HEPA cartridge
Collected while moving enclosures and while moving chute in basement.
Collected in hallway just outside of negative pressure enclosures between labs 313 and 315.
Basement under pipe chases.
Collected while removing asbestos inside negative pressure enclosun from 60 feet of line.
Collected while removing asbestos inside negative pressure enclosure frem 60 feet of line.
8-20-87
Source
8-20-87
Personal/
8-20-87
Area
8-20-87
8-20-87
Area
2hrs 1Stain ^0.005
VOIDED Hole in middle of filter cassette
5hr$ 2Ctain 0.006
-
lhr 2Ctain
2.677
4hrs 57min ^O.OW
"
Full face supplied air
-
Full face supplied air
-
Conp. Ref. W227i
Collected inside of negative pressure enclosure before pulling away from wal 1 - the HEPA filtered vacuum had run for approx. 24 hours before this sanple was collected.
Collected on 3rd floor between the 2 pipe chases being stripped.
Collected while stripping approx. 50 feet of asbestos from 2 pipe chases - inside of negative pressure enclosure.
Collected in the basement directly under the pipe chases being stripped.
UCC 011363
ASBESTOS EXPOSURE MONITORING - 701 (continued)
Conp. Ref. W227:
Date
8-21-87
: 8-21-87
1
\ 8-21-87
i i` T
: 8-21-87
Sarple Type/ Employee Name
Sanpling Time
Air Cone, fibers/oc
TWs
fibers/oc
Type of Respirator
Used
Area
5hrs 35min 0.016
-
-
Area
5hrs 23min 0.013
--
lhr 29m'n
0.302
lhr 29hrin
0.783
-
AO R57A Half face HEPA cartridge
AO R57A Half face HEPA cartridge
COMMENTS
Collected in the exhaust air coming from Micro trap;
Collected in basement - east end - under the pipe chases where pipefitters were working.
Collected while removing asbestos from pipe chases (60 feet) inside of negative pressure enclosure.
Collected while removing asbestos from pipe chases (60 feet) inside of negative pressure enclosure.
ASBESTOS
Permissible Exposure Level
TWgj
~(T.2 fibers/oc OSHA
Action Level 0.1 fibers/cc
26A6P