Document M4waew304VmVwOqwxpo9Zmyb7

VAPOR-PHASE depreoslng 1} done with vapor ized solvent in IorV. Cold motor condenses vtJpor, which rum off carrying grease, dirt ARMATURE in degreasing vopor. If port slays in lonk'unfijfl it reaches vapor temperoture, uncondensed solvent will am&s point and vornlsh films. Remove part before condensing ttouj| itfS'i TANKS for dipping should stay at room temperature, be covered when jflIU/. In use. Heat end exposure to oir will change vornlsh specific provlty ond viscosity. Preheated parts should cool below 140 F before dipping MOTOR frame, field colli get varnish dip. Aftor soaking, drain for at leosl ono hour, then bake at 273 F, or obovc Cleaning, Dipping and Baking fipHHr Your Electrical Varnish Jobs Many varnithing Ills stem from grease, dirt and other contaminants on dipped part Others come from specific gravity or viscosity rhonges due to heat and oxidation Bad mixing and proportion between varnish and thinner can give tots of trouble, too Here is a rundown of good efeaning methods and ways to keep your varnish in tiptop condition for best dipping, im pregnating and baking jobs Foh a gooo varnish job, the piece must be clean. A lot depends on this step because a good many varnishing problems can be traced directly vo grease, dirt and old insulation missed in the cleaning operation- Several cleaning methods are com monly used: (1) hand washing with suitable aolvent or detergent, using rags or brushes (2) pressure spraying with solvents or a steam jenny (3) vaporphaso degreasing (4) pressure bloating with mildly abrasive material (5) com bination of two or more. Hand washing is (be most common method. It con be used on equipment of all sites and calls for the least capi tal outlay. Solvents for hand cleaning include naphtha, Stoddard's solvent (a mixture of cleoning naphtha and carbon lotrachloride), trichloroethylene and perchlorocthyfene. Naphtha fs highly flammable and fumes from other threo are somewhat tonic,' so cleaning with solvents should be done only when well away from flame, heat or sparks, ond with good air circulation. Du Pont has developed a cleaning mixture (hat minimizes the bed points of petroleum solvents. It is marketed under the name Cleaning Mixture 149. Delergeni solutions are sometimes used, but aren't as effective as solveatj9 Detergents, too, are not chemically oesyff tral, end must bo rinsed thorough^, from clesn coils or Insulation will slo'ulfU deteriorate. .ffl Prasturo-spray cleaning with lobrotH! or steam is faster ond more thoroojbjE than hand washing. Precautions witha solvents, of course, must still be uswR Steam end water vapor will not brntS insulation and varnish film but, iiai| water and grease don't mix, steam njjj not aa fast as solvent spraying. Vapor-photo degreasing Is a rdi-S lively new development. ChlotiaiwfSi solvent, such as trichloroethylene Mg perchloroethylene, Is heated in a elated* lank until it vaporizes. When dirty paifR is lowered into hot vapor, solvent eoo- densei on cold surfaces, runs off ctrrj-jfl ing dirt and grease. If, however, piw*D stays in tank until Its temperature reaches that of vapor, uncondensed vent will attack paint and varnish Air blasting with mildly abrasive (criot, such as ground corncobs, bj another recent cleaning method. SuajbjH ard sandblasting equipment con he"*"A for this job. For best results, P*,ec toeuld first be solvent cleaned, with |pt(ng used to remove brittle varnish foa^Without injury to winding or mica trmnmtalor Insulation. IlAU these methods work if dono propny^BiH most Important is gelling jffig/completely clean before varnishjjjjyEach unit should also bo baked healed before treatment, let them cool to 140 F or. below before dipping. Heat ing varnish will increase viscosity and - evaporate thinner. Keep tanks covered at all times when not in use to prevent oxidation of oils and evaporation of solvent. A blanket or slight pressure of an inert gns like ulate or separate out of your solution. When mixing thinner with varnish, be sure both are about (he same temperalure. Adding warm thinner to cold vor nlsh or cold thinner to warm varnish may cause varnish base to go out of solution. Add thinner slowly with con stant stirring to make sure of thorough ^Tjsnd tested after any cleaning, and fere.lreotlng with varnish. ` odern Insulating varnishes use a mthetlc retin base (bakellte, polyesJ^glyptat, eie). These materials are carbon dioxide (COa) or nitrogen <Nj) in storoge tanka is very helpful- Stir tanks often (o cut separation of sol vents from solids. If it's necessary to treat a dirty piece,, mix. When you reach proper consistency, measure specific gravity with a hydrom eter designed for liquids lighter than water. Then bold (hat specific gravity iJeaijreaetuie, that is, they set up and fi&by heat Some oils blended with klHjreslns require oxidation to cure, !|*nee the combination of heat and air wrap it in muslin or duck cloth. When part is drained, sock will catch most contamination. In systems having re circulation or transfer pumps, filter la by adding thinner to within plus or minus .001. Specific gravity will also vary with temperature, so correct meas urements to same standard temperature flicking ovens. often put in line to -strain out solid used for viscosity tests. varnish in tanks is (1) warmed particles. For best results in vacuum Impreg jjftjireheited ports being dipped (2) VomtSh viscosity will go up even nation, preheat piece in baking oven, end its solvent evaporated by |.rfsc'e exposure to air, and (3) con|hoinsted by ail, dirt, carlmn and grease rfv/0-11 objects immersed. So it's almost Jgjpe'uihle to keep need varnish in top when specific gravity is held constant. This is especially (rue in large tanks that seldom have new varnish added. So it's wise to measure viscosity at least iwicc a week. Because viscosity varies and let cool to 140 F or below. Place in tank and draw best vacuum possible. Slop vacuum pump. Then, without hreoking vacuum, admit varnish until lift level is at least 12 in. above wind Addition unless carefully handled tin- wiili temperature, bring your sample if ings. Rclcose vacuum and let part aoak. ^rtoptimum condilious. Here ore some hints to fol- u constant standard temperature each lime before measuring. Holding down viscosity with n lot of If you like, apply 75-80 psi inert atmos phere (CO.j or Nf) above varnish. Transfer vurnish back to storage tank Jljttp vuriii,li In dip rn vucmim iiu- (liiuncr can be tricky. ff proportion of and let piece drain for at least one gjfjfcnatinn tanks close In room tern- thinner In nonvolatile content of vurnlsli hour. Then bake wfifi good air circula Wore, 70 in 90 F. If parts are pre gets loo high, varnish base will coag tion at not less than 275 F. PLANT OPERATION AND MAINTENANCE SECTION .ownilWawy,,, PLANT OPERATION AND MAINTENANCE SECTION igfc U& m