Document M4w1zaL5Jj4d15VwDVBLMj3v7
Monsa.ito
' " David Wood-St. Louis
July 30, 1974
miiiiiii
PCBs AUSTRALIAN ELECTRICAL ...... MANUFACTURERS' ASSOCIATION
TO :W. B. Papageorge B1NB
fc &
CL P. G. Benignus C. Paton R. F. Garnsworthy-Melbourne
Robin Garnsworthy sent us the attached letter from Endurance Electric, one of our askarel customers in Australia to R. E, Brett of A.E.M.A. in Canberra. Cooper has been requested to prepare for AEMA a recommendation for handling of PCBs to satisfy the unions, who in some Australian plants have virtually refused to work with PCBs until more meaningful safety recom mendations have been published. Could you please let Robin have your comments on Cooper's proposal.* Thank you.
/deb Attachment
'ood
MQNS 028763
Monsanto
PROM (NAME & LOCATION)
K.F# Garnsworthy - Princes uate - Melbourne
8th July, 197A
SUBJECT
PCB's - A.E.M.A. AUSTRALIA
nBFCIIENCE TO
D, Wood, ST. LOUIS
I am attaching a copy of a letter from Cooper of Endurance to R.E. Brett of the A.E.M.A, in Canberra.
It is my intention to visit Brett in the near future, but before doing so, you may wish to comment on the 'industries' recommendation to the Australian Electrical Manufacturers Association.
RFC:lhs Att,
HONS 028764
M. PAAClEAW
13'J.IM WOOOVILLE ROAD, VILi.AWOOD, N.S.W., AUSTRALIA 2103
youh ner
Hr. R. E. Brett Executive Director A. E. M.A Industry House CANBERRA 2600 A.C.T.
727 BOOB RJC PAL
26th June, 1974
Dear Sir,
As promised, I have completed, and am enclosing a set of "Recommended Instructions for Handling P.C.B.'s In the Electrical Industry" which should be circulated to the various companies in A.E.M.A. handling 'Chlorinated Hydrocarbons (or P.C.B.'s) for their comments prior to
general issue and prior to formally replying to the E.T.U. letter to A.E.M.A. dated 11th January, 1974.
F.NCL.
Yours faithfully ENDURANCE ELECTRIC PTY LIMIfED
Rf J. COOPER GENERAL MANAGER.
HONS 028765
ri.co:riimii jns r rijcj ious tor jianikjng p r_c__'s in rue electrical inuui-11-;
fjO[C` P.C B stands, for Polychlorinated biphenyl and is a fluid which comes under various trade names, the most common in Australia being
AROCLOR PYROCLOR PYRALEHE CLOPHEN
P C.B fluids which are used in seme electrical transformers and capacitors come in 44 gallon (6001b or 272kG) drums and in the case of Pyroclor and Aroclor have a "Harmful Substances" sign^l prominently displayed on each drum, together with ''Caution" notices and instructions (m four languages) on handling, use and disposal.
*4************************
' 1. PERSONAL SAFETY
p.C.B.'s for use in transformers and capacitors have been made, handled, and used for over 40 years with the very limited hazard to personal health being confined to occasional cases of temporary skin lesions or irritations.
i However, abusive use of P.C.B.'s may have longer term, more serious health problems and therefore every care should be taken not to allow P.C.B. fluid or fumes to enter the body e.g. through pores of skin, swallowing, inhalation or in the eyes.
2, PERSONAL PRECAUTIONS.
a. Skin Protect the skin by wearing neoprene coated aprons and P.V.C impregnated cotton gloves. Barrier creams are of some value where the use of gloves is impractical.
If P.C.B. does come into contact with the skin then wash the affected area with soap and warm water.
bJ__ Eyes Safety spectacles must be worn at all times when handling PX.B.T. Should P.C.B. enter the eyes then immediately wash the eyes well by flushing with large quantities of clean running water.
r on
HONS 028766
2- -
)
__Breathing At room temperature P C.U.'s give off negligible fumes and are therefore harmless to breathing. However, at elevated temperatures via hot ovens, welding etc where vapours arc apparent, inhalation of these vapours must be strictly avoided by us'ny prcDer exhaust ventilation and organic cartridge respirator (in confined areas) or air blowing apparatus (in more open areas) away from operators.
SMOKING MUST BE STRICTLY FORBIDDEN
d Swallowing If P.C.B. is swallowed then voimtting should be induced" immediately by carefully inserting a finger in the person's throat. Do not give stimulants A doctor must be consulted as soon as possible.
e. Contaminated Clothing Badly P.C.B. soaked clothing should be disposed of, as Til 4. below.
Partially P.C.B. splashed clothing should be laundered before wearing again to avoid possible skin irritation,
3_.___TRANSFER OF P.C.B. 's
When pumping P.C.B.'s from drums into factory storage tanks, ensure that no spillage occurs and that drums are completely drained and flushed twice with kerosene type solvent (*Refer 4 below) prior to scrapping. P.C.B, containers must not be re-used for purposes other than storage of P.C.B.'s
4. HASTE DISPOSAL OF P.C.B,'s
If P.C.B. spillage does occur then quick remedial action must be taken to tfISURL THAT THE FLUID OOES NOT ENTER THE ENVIRONMENT especially drains, canals, and other waterways. Suitable oil soahage material such as 'oilzerb', sawdust, rags, etc, should be used to quickly absorb the P.C.B. The contaminated materials must then be placed into sealable and prominently marked "P.C.B, CONTAMINATED HASTE" (Refer attachment 1.)
44 gallon drums for dipsosal of contents in 1100C furnace or by the Metropolitan Waste Disposal Authority.
Excess or unuscable*P.C.B. and kerosene*flushed P.C.B. are to be
stored "in "sealed and prominently marked "HASTE FLUID" (Refer to
attachment 2.) 44 gallon drums or other suitable sealed container
prior to disposal by incineration in 110DC furnace or by the Metro
politan Waste Disposal Authority.
cont
MOWS 028767
-3_raun_n,[CTPiCAL equipment P.C B. filled transformers and capacitors which arc to be scrapped must first be completely drained of the fluid (precautions and fluid disposal as above). If high value material such as copper is to be reclaimed then this should bo removed and washed in Kerosene (*Refer 4 above) prior to re-use. All unwanted solid materials must be sealed up inside the transformer or capacitor tank or in 44 gallon drums for disposal in controlled dry land-fill areas. The tanks or drums should bo prominently marked "SCRAP P.C.13 SOLID WASTE FOR CONTROLLED ORY LAND-FILL BURIAL" {Refer attachment 3.)
HONS 0287*8
HONS 028769
ATTACH HLMy 2
HONS 028770
A T T A C II H I n r !
(P0LYCNLG31NATE0 BIPHENYL)
HONS 028771