Document M4rarRrx60Z9OmQXM64pmoDZM

MINUTES of ths TECHNICAL & RESEARCH COMMITTEE MEETING San Francisco, California June 24, 1968 MINERAL FIBER SECTION The meeting came to order at 9*15 with the following in attendance: AGENDA Mr. C.E. Ernst Mr. W. Gubar Mr. S. Heard Mr. J. Dorsey (JM) (GB) (OCF) (Old) Mr. B. White Mr. T. Campbell Mr. W.T. Irwin (OCF) (OCF) (PEG) 1. (a) Revised Guide Specification CE-201.01, Metal Buildings has been submitted to MIMA for comment. (b) W.T. Irwin will circulate copies to committee members with. the request for comments to.be returned by July 10th, 1968. 2. ' ASTM Specification - Combined C 378 and C 392* (a) Copies of this ASTM specification will be circulated to T u R Committee Members by W.T. Irwin. (b) Committee unanimously agreed to recommend the deletion of Section 5.1.1 Alkalinity because it is insufficiently definitive. There are two properties of mineral fiber insulation in which alka linity may have bearing: durability and corrosion resistance. It is believed that resistance to corrosion on steel, aluminum, and copper is of greater importance. If this be the case, a program is required to establish an ASTM test for corrosion and/or establish reliable correlation that alkalinity of 0.60$ is a proper measure of corrosion resistance. (c) C. Ernst is to check the present status of this specification in ASTM C-l6 S-l and recommend that Alkalinity be deleted. (d) W. Irwin to poll members regarding Type 1, Class 4. Page (2) Two 3. Exchange of Member Literature (a) Each member has been requested to send 15 copies of current ~ literature to J.M. Barnhart for collating and distribution to T & R Members by August 1st, 1966. (b) It is also recommended that this literature exchange be ini tiated by J.M. Barnhart on an annual basis. it* Duct Liner Specification (a) Committee advised that NIMA Duct Comittee has prepared this specification along the lines of Fed. Spec. UL l8l, and the CSI.format. (b) Committee recommends that this specification be reviewed (by the Duct Committee) on an annual basis or as required. 5> Federal Specification HH-I-5^5 (a) Committee unanimous in opinion that HH-I-5^5 should stand on its own and not be combined with HH-I-558. Liners are designed for a specific end use and have properties and requirements which should not influence or be influenced by inclusion in the general thermal insulation specification. The different end use, and in stallation by different trades, and difference in location in guide specifications are considered valid reasons for maintaining the separate specification status for duct liners. (b) Committee requests J.M. 3arnhart to circulate the rewrite of this specification to this Committee reflecting the decisions and discusssions of the joint meeting of NEiA Gov't T & R and GSA in March 1$68. 6, Federal Specification HH-I-556 (a) W.T. Irwin to circulate copies of Interim Amendment-1 dated 3rd October 1967 to the Committee. This amendment includes a cross-reference table keying forms and classes of KK-I-55S to forms, classes, and types in the superseded Federal Specifica tions . (b) W.T. Irwin to poll member companies regarding need for revisions: .1 Should Form A, Class l; be retained? Anv changes bevcr.d those described in minutes of September 19^7 meeting? Page (3) Three The Gov't T & R Committee to be advised of recommended changes. In addition, the Gov't T & R Committee is to be advised of the T & R negative opinion on combining HK-I-5U5 into HH-I-558. 7. UL Fire Hazard Classification (a) Committee in accord that best interests of consumers, code writers, manufacturers, and UL would be better served with a revised UL label system based on group classifications. One such class would group products having a flame spread not over 25 and smoke developed not over 50. (tj) At least one member has adopted a voluntary program of pro moting this concept. () W, Gubar and W.T. Irwin to prepare and circulate a program to be presented to UL following T & R review. Initial draft is to be completed by July 23rd, 1968. 8. UL Pipe and Equipment Category - Systems J. Dorsey presented views on potential industry problems connected with establishing pipe insulation systems at UL. The systems approaches on duct liner, duct wrap have been de-enphasiced because, of economic, legal, and enforcement difficulties. These same difficulties may also be present if pipe insulation systems are encouraged at UL. Members are to discuss this situation with thefr principals and decide on: No action, act as NIMA on pipe systems, act as individuals on pipe systems. 9. Military Specification MIL-I-223UH (a) T. Campbell requested NIMA T & R to seek deletion of fiber dia meter requirement and to increase the nominal density upper limit to 8 lbs./ft.3. (b) W. Irwin to initiate letter ballot by July 5th, 1988. 10. Other Business Increased activity in all phases of NIMA operations has resulted in increased demands on the time and attention of the Secretary. The T L R Committee believes the Board of Directors will agree that improved efiectiveness of internal and external, communications v.'ill be acnieved if iul_ time secretarial services arc provided in the MIMA oificc to relieve sea.: of the increased burden on the LMv-.-euclve Secretary. Page (4) Four 11. The Committee thanks Mr. T. Campbell and Mr. J. Dorsey for all their past services to NIMA and the T & R Committee, and wishes them veil in their new responsibilities which unfortunately requires them to relin quish membership on the T & R Committee. 12. The Committee thanks Mr. K. Ritchie for years of service to NIMA and the T & R Committee and wishes him well upon his retirement. Respectfully submitted, W.T. Irwin, Chairman, Mineral Fiber Section, NIMA T & R COMMITTEE