Document M4pxgQR1b6J5BqYr9eDjOg3xk

HOT WORKING OF METALS equipment should be constructed with a fac tor of safety of at least 10 The diameter of the head on the outside end of the trunnion shaft should be not less than one and onehalf tunes the diameter of the trunnion shaft The inside comers where the trun nion shaft joins the base and the head should be filleted to prevent the sling or hook from tiding the trunnion base or bead Inoculation or treatment of molten metal to desulfurize it or to change its composi tion or type, as in the making of an alloy or ductile iron, is done in the reservoir or in a pouring ladle A hood can be made to cover this operation so that the workmen are ef fectively shielded from possible spatters of metal caused by the violence of the reaction The resulting fumes are drawn off and ex hausted through a stack Fig. 27-2. Tilting ladle equipped with manually operated anti-tilt lever shown In white Hoist control switch cable Is at left. Suitable covers should be provided on portable ladles The run or lip on band or bull ladles should be built up above the top of the metal shell with fire day no more than V4 m. if the refractory ladle lining is less than 1% in thick at the ran In any case, the maxi mum height of the run or hp should be not greater than 1 in Ladles should be thoroughly dned out be fore being used Local exhaust should be provided to control vapors or fumes pro duced during ladle drying. Some foundries control both vapors and excessive noise pro duced by gas torches used for drying by performing all operations in a ladle-drying shed located outside the foundry Monorail ladles and trucks used to trans port molten metal ladles should be equipped with warning devices (bells or sirens) to be used whenever molten metal is being trans ported. Trunnions and the devices used to attach them to Basks, buckets, ladles, and other Hoists and cranes Pull chains, switches, or valves which op erate air and electric hoists from the floor should be plainly marked "hoist" or 'lower " Swivel load-canying hooks should be at tached to a shank or bolt by means of a threaded nut, that is locked in place with a pm or other locking device to prevent the swiveling aebon of the hook from turning the nut Mechanically operated hoisbng equipment should have limit switches that will prevent the lower block from being pulled into the hoisting drums or overtraveling in the low ered position. Overhead and gantry crane tracks should be equipped with track wheel bumpers that will stop the crane and prevent it from run ning off the crane runway or striking the building structure Bumpers should be ac curately located so that the crane or track can be realigned by sighting along a center line between the bumpers Bumpers should be anchored not only to the crane rails but also the rail girders or other supporting members The load-carrying parts of crane buckets "Details for local exhaust removal of con taminants generated in this operation may be found m Engineering Manual for Control of In-Fhnt Environment in Foundries. American Fouodrymen's Society. 1956. 27-8