Document M4aqqy9rxz22KXEGNMpMZNKrM
'Monsanto industrial chemicals co.
R. . Keller - T18
September 30, 1975
--- nffTEO OIBENZOFURANNSSIN>CBs
- .
memo to REJL-et'al
O : W. B. Papageorge B2SK
CL H. S. Bergen - B2SL
O. P. Mieure - T2F
R. H. Munch - TIB
C. Paton
- B2SC
R. G- Potter - B3SA
W. R. Richard - T3A
d>. Wood .
- B25D
P. L. Wright - A2SC
x . in ki v
This memo summarizes progress on the action plan covered by the reference memo. All Items below were targeted for completion by October 1.
1. Arrange for the preparation of the required furan standards.
The following laboratory mixtures were prepared by Q. E. Thompson:
(a) Mono-, dl- and trl-chlorinated dlbenzofurans; fb) Tri- and tetra-chlorlnated dlbenzofurans; (c) Penta-, hexa- and hepta'-chlorinated dibenzofurans.
These mixtures have been characterized for the homologue composition by GC and GC/MS.
Small quantities of the above mixtures were sent to R. Lidgett at Louvaln-La-Neuve on 9-15-75 for method development work related to pentachlorophenol.
2. Refine analytical methodolegy to achieve detection levels of at least 0.1 ppm for each furan homologue.
Our earlier methodology permits measurement of each chlorinated dibenzofuran Isomer in PCB products as follows.
Detection Limit
Tetra- through Hexachlorod1benzofurans
0.5 ppm (each component)
Mono* through Tri Chi orlna ted Dibenzofuran
Unknown (>10 ppm)
Tl* goal for the above action was to develop a method with detection ltatt of 0.1 ppm for each of the above components.
We have developed methodology over the past two months which is believed to have the necessary detection limit of 0.1 ppm for tetrathrough hexachlorodlbenzofurans. However, we have been unable to
validate this detection limit because we find about 1 ppm total for
those- Isomers in Aroclor 1254. We have been unable to develop Improved methodology for measurement of mono- through trl-chlorinated
dibenzofuran In Aroclor 1016 after several man months of effort.
We have found that methodology reported by the FDA for these measurements cannot be reproduced in our laboratories. We have
several more analytical schemes to try to resolve the above problems.
MONS 202295
I. W. B. Papageorge -2- September 30, 1975
3. Arrange with outside laboratory to confirm accuracy and reproducibi 1 ity of methodology.
No action on this since results have not been obtained yet for
Item 2 above.
4. Arrange with P. J. Marsh and R. A. Baxter for discussion with Bayer for possible mutual exchange of Information relating to furan analyses.
Contacts have been made with Monsanto-Europe. Most recent memo reply to REK from R. A. Baxter on 8-19-75 indicates that there will likely not be any information of significance coming from Bayer or Predelec.
5. Analyze Aroclor products produced at Sauget and Newport. Samples to Include currently produced material as well as material produced prior to 1970.
Materials have been received from both plants. Samples are being held until completion of item 2 above.
Overall, we have not yet achieved the total capabilities needed for deter
mination of 0.1 ppm chlorinated dibenzofurans In PCB products. It Is our
understanding that justification for continuing this analytical research
Is based on showing that the level of chlorinated dibenzofurans is below
toxicological significance (<0.1 ppm). Even though the odds of success
are not high, we plan to continue with one additional man month of effort
on this project. Recipients are asked to advise us if they are not in
agreement.
*
R. E. Keller
HONS 202296