586 CHAPTER 26 1952 Guide metal pipe made of a good grade of cast-iron with or without additions of nickel, chromium, or other alloy. This pipe is available in sizes from 1J in. to 6 in., and in standard lengths of 5 or 6 ft, with external and internal diameters closely approximating those of extra strongswrought pipe. Castferrous pipe may be obtained coupled, beveled for welding, or with ends plain or grooved for the several types of couplings. It is easily cut and threaded as well as welded. The fact that it is readily welded enables the manufacturers to supply the pipe in any lengths practicable for handling. Alloy Metal Pipe. Steel pipe bearing a small alloy of copper or other alloying element, and iron pipe bearing a small amount of copper and molyb- Table 1. Dimensions of Schedules 30 and 40 and Standard Weight Pipe* Diameter In. Size i s =3 . Weight pee Ft, Lb ClBCUUPBBBNCB, In. d. xf . I i W - sK d 11 E f! 1 ! s. External Internal Surface Transverse Area, So In. r <3 aa . 0 3 s Length op Pipe, Ft per Sq Ft 1 00 -3 5 u Length op Pipe, Ft Con taining ICoFt Weight op Water, la per Ft 0.405 0.269 0.068 0344 0345 27 V, 0.540 0364 0.088 0.424 . 0.425 18 k 0.675 0.493 0.091 0567 056S 18 0.840 0-622 0.109 0350 0352 14 1.272 1.696 2.121 2.639 0345 1.144 1549 1.954 0.129 0.057 0.072 9.431 14.199 2533.775 0.229 . 0.104 0.125 7.073 10.493 1383.789 0358 0.191 0.167 5.658 7.748 764360 0554 0304 . 0350 4547 6:141 ' 473.906 0325 0.045 0.083 0.132 X 1 1H IM 1.050 1-315 1.660 1.900 0.824 0.113 1.130 1.134 14 1.049 0.133 1.678 1.684 im 1380 0.140 2.272 2.281 im 1.610 0.145 2.717 * 2.731 UH 3399 4.131 5315 5.969 2589 3.296 4.335 5.058 0.866 1358 2.164 2335 0533 0364 1.495 2.036 0333 3.637 0.494 2304 0.669 2301 0.799 2310 4.635 3.641 2.768 2372 270.034 166.618 96375 70.733 0331 0375 0.65 038 12 2375 ,2M ,2375 3 3-500 za 4.000 2.067 0.154 2.469 0303 3.068 0.21B 3548 0.228 3.652 5.793 7575 9.109 3.678 11H 7.461 6.494 4.430 5319 8 9.032 7.757 .. 6.492 7.616 8 10.996 9.638 9521 9302 8 12566 11.146 12566 3355 : 1.075 4.788 1.704 7393 2.228 9386 2.680 1.608 132S 1.091 0.954 1347 42.913 1547 30.077 1345 19.479 1.076 . 14565 1.45 2.07 3.20 439 -4 ` 4300 4.026 0.237 io.790 10389 8 14.137 12.648 15.904 12.730 3.174 0.848 0.948 ' 11312 5.50 5 5563 5.047 0.258 14.617 14310 8 17.477 15.856 24 306 20.006 4300 0.686 0.756 7.198 8.67 6 6.625 6.065 0.280 18.974 19.185 8 20313 19.054 34.472 28.891 5581 0576 0.629 4.984 1251 8C 8.625 8.071 0277 24.696 25:000 8 27 096 25356 58.426 51.161 7365 0.443 0.473 2 815 22.18 8 8.625 7.081 0322 28554 28.809 8 27.096 25.073 58.426 50327 8399 0.443 0.478 . . 2378 21.70 10C 10.750 10.136 0307 34.240 35.000 8 33.772 31343 90.763 80.691 10.072 0.355 0376 10. 1G.750 10520 0385 40.483 41.132 8 33.772 31.479 90.763 78355 11.908 0355 0381 1.785 34.95 1326 3430 12c 12.750 12.090 0330 43.773 45.000 8 40.055 37.982 127.676 11430Q 12 876 0399 0315 1354 49.70 12 12.750 12.000 0375 49562 50.706 8 40.055 37.699 127.676 113.097 14579 0399 0318 . 1373 49.00 * Standard-weight wrought-iron pipe has approximately the same wall thicknesses and weights as con tained herein for steel pipe.. For exact dimensions, see American Standard for Wrought-Iron-and WroughtSteel Pipe, ASA B36.10. ' ^ Thicknesses shown in bold face type are identical with thicknesses for Schedule 40 pipe of ASA B36.10. *Same as Schedule 30, ASA B36.10.'- denum, have been claimed to possess more resistance to corrosion than plain steel pipe and they are advertised and sold under various trade names. , Copper Pipe and. Fittings. Owing to inherent resistance to corrosion, copper and brass pipe have always been' used in heating, ventilating, and water supply, installations, but the cost with standard dimensions for threaded connections has been high. The recent introduction of fittings which permit erection by soldering or sweating, allows the use of pipe with thinner walls than would be possible with threaded connections, thereby reducing the cost of installations. , The initial cost of brass and copper pipe installations generally runs higher than the corresponding job with steel pipe and screwed connections in spite of the use of thin wall pipe, but the corrosive nature of the fluid Pipe, Fittings, Welding 587 conveyed or the inaccessibility of some of the piping may. warrant, use of a more expensive material than plain steel. The advantages of corrosion* resisting pipe and fittings should- be weighed against the correspondingly higher initial cost. COMMERCIAL PIPE DIMENSIONS The two weights of steel and wrought-iron pipe commonly used are known as standard weight and extra strong, which correspond to Schedules 40 and 80, respectively, of the American Standard for Wrought-iron and WroughtSteel Pipe, dSA B36.10. The same external diameter is used for both Table 2. Standard Weights and Dimensions of Welded and Seamless Steel Pipe* Standard-Weight Pipe Extra-Strong Pipb DoubuiExtra0 Pipxb Outside No. op Diame Threads ter. In. per In. Schedule 30. Wall Weight Thick per Ft, ness. Lb In. TAC Schedule 40 . Wall Thick ness, In. Wright per Ft, Lb TAC Schedule 60 Wan Thick ness, Id. Wright per Ft, Lb Plain Ends Schedule 80 Wall Thick ness, In. Weight per Ft, Lb Plain Ends Wan Thick ness In. WHee*igh-t Plain vs X VS M X 1 IX w 2 JM 3 3M 4 5` 6 8 10o 12d 0.405 0540 0.675 0340 1.050 1315 1.660 1.900 2375 2375 3500 4.000 4500 5.563 6.625 8.625 10.750 12.750 27 18 18 14 14 UH UH im 11H 8 8 8 8 8 8 8 8 8 -- -- ... . ---- -- 0.277 0307 0330 2540 35.00 45.00 0.068 0.088 0.091 0.109 0.113 0.133 0.140 0.145 0.154 0303 0.216 0326 0337 0358 0380 0322 0365 0375 035 0.43 057 035 1.13 1.68 238 2.73 3.68 532 7.62 930 1039 1431 19.19 2841 41.13 50.71 -- -- -- . -------- - 0500 54.74 05008 65.41 0495 0.119 0.126 0.147 031 054 0.74 1.09 0.154 1.47 0.179 2.17 0.191 : 340 0.200 3.63 0318 5.02 0378 7.66 0300 1035 0318 1251 0337 . 14.98 0375 20.78 0.432 2857 0500 ' 4339 -- -- 0394 0308 0358 0.382 0.400 0.436 .0552 0.600 0.636 0.674 0.750 0364 0375 1.71 2.44 3.66 531 6.41 9.03 13.70 1858 2235 2754 3855 53.16 72.42 -- From Standard Specifications for Welded and Seamless Steel Pipe of the American Societv for TtUino MatmaU, A.S.T.M. Designation A120. * Sizes larger than those shown in the table are measured by their outside diameter, such as 14 in. outside diameter, etc. ' These larger sizes will be furnished with plain ends, unless otherwise specified. The weights will correspond to the manufacturers* published standards although it is passible to calculate the theoretical weights for any given size and wall thickness on the basis of 1 cu in. of steel weighing 0.2833 lb. b The American Standard for Wrought-iron and Wrought-Steel Pipe ASA B36.10-1939 has assigned no schedule number to Double Extra-Strong pipe. c A 10 in. Standard Weight pipe is also available with 0.279 in. wall thickness, but this wall is not covered by a Schedule Number. , ** Owing to a departure from the Standard-Weight and Extra-Strong wall thicknesses for the 12 in. nominal uze, Schedules 40 and 60, Table 2 of the A5A B36.10-1939, Standard for Wrought-iron and Wrought-Steel Pipe, the regular Standard and Extra-Strong wall thicknesses (0.375 in. and 0500 m.) have been substituted. weights of each nominal size for manufacturing reasons, as well as to afford interchangeability in threading and other elements associated with fabri cation and erection. Hence, the difference in wall thickness is accom panied by a corresponding change in inside diameter. In sizes up to 14 in., pipe is designated by its nominal size which corresponds roughly to the inside diameter of Schedule 40 pipe. In sizes 14 in. and upward, pipe is designated by its outside diameter (O.D.), and the wall thickness is speci fied. While the demands for pipe for the heating and ventilating industry are reasonably well served by Schedule 40 (standard weight) pipe, the erection