Document M4M8aVj3pGLV3b72jNnrpDdw9

# Reading File January-Febmary, 1976 mi, Jm, if \.T -=} ^.. Jhi-JSPJf. I--=-*i--..,U n/r.-c- ..) a.^.4gvW4SaAiiitW'-isfe, a - -!-j:-:'--.7j.?;'r-ii i ;~-^ r - V,, 0^23%7 Mr. Robert S. Clark Technical Center South Charleston Bldg. 770-201 January 30, 1976 Medical Department 4 Numerical Cbde Ord r For Volume 38 Dear Mr, Clark: Bte recently received a listing in numerical code order of the current methods for the Industrial Hygiene Handbook. Please be advised that the following methods are missing In our handbook. Method No. Partial Title 38C- lP4-RZb 38C-1P4-R2. la 38C-2A2.40-R2 38C-9C1-R2b 38C-10X2-R2.1 38C-10X2-RZ.2 38C-10X2-R2. 3a 38C-19B1-R2.2 38C-22S4-R2 38C-22T1-R2 38C-Z9B82-R2 38C-29F1-R2 38C-27P1-R2 38C-U1A15-R2a 38C-Y4A-R2 3?C -/(HI Sulfur dioxide Sulfur dioxide Vinyl acetate Vinyl chloride Particulate & organic matter Particulate matter Particulate fallout Dimethylfo rmamide T et ramethyl succ laonitrile Acrylonitrile Lead Sulfuric acid mist Cobalt carbonyl Carbaryl (SEVIN) 3,4 Benzopyrene tmji/oe &lyc*L. Very truly yours. CUD :1m C. U. Dernehl, M. D. Associate Corporate Medical Director Mr. J. H. Skahill Battery Products Division 1205 Broadway Red Oak, Iowa January 23, 1976 edieal Department Mr. R. Christie/Mr. T. Burke Mr. . Domokos Mr. K. F. Griffin Mr. G. L. H&rshaw Mr. P. J. Kennedy Dr. J. J. Welsh/Dr. K. S. Lane Dear Mr. Skahill: Industrial Hygiene Survey; Red Oak - December 10-11, 1975 BUSHOSSS CONFIDENTIAL A routine periodic industrial hygiene survey was conducted at the Red Oak plant on December 10-11, 1975. All plant areas were inspected, and air samples were collected for airborne dusts, fumes and vapors. These air samples were analyzed for total dust, arsenic, manganese, lead, vinyl chloride monomer, perchlorethylene and methyl lsobutyl ketone (MIBK). This second set of air samples collected here for arsenic analysis yielded results which were quite comparable to those of the first set. The results of air samples collected for approximately hours each on a Mix Screener and a Cramlc Molding Machine Operator showed a time-weighted average exposure of less than 0.001 mg/M^ to arsenic. Thus, each of the U shift-length air samples collected in this mixing and forming area during 1975 gave results of less than 0.001 mg/M^ as the time-weighted avergge concentration for exposure to airborne arsenic. This is less than 0.2^ of the existing OSHA standard for arsenic, and less than 50^ oven of the proposed new threshold limit value. The time-weighted average concentrations for the exposure of the Mix Screener and the Cramlc Molding Machine Operator to airborne manganese dusts were 0.30 and 0.29 mg/M^, respectively. Thus, the average exposure measured here during 1975 for each of 3 job classifications (also Mix Operator) was less than 10)6 of the threshold limit value for manganese in workroom air. A personal air sample was collected for approximately 6 hours on one of the operators on the finishing line. This gave a time-weighted average concentration for lead of less than 0.004 ng/M^. This calculates to be less than 2jt of the existing threshold Limit value for lead in workroom air. This was the only such sample collected here for lead analysis during 1975* ucc 62369 Mr. J. H. Skahill -2- January 23, 1976 The expoeure to total dust and fume continues to be acceptably low at operations in the Red Oak plant. During this visit the time-weighted average exposures to total dust and fume for the Cmamlc Molding Machine Operator, Mix Screener, and Finishing Line Operator ware 2.09, 1.71, and 0.06 mg/M3, respectively. the air sample collected for approximately 7-hours (12/10/75) on the Extrusion Machine Operator contained less than 0.05 parts per million (by volume) of vinyl chloride monomer. Thus, none of the air samples collected on this operator has ever contained as much as the OSHA action level of 0.5 parts per million (by voluae) of vinyl-chloride monomer as a time-weighted average concentration. During the afternoon of 12/10/75, spot air samples were collected for perchlorethylene in the aisle beside both the Blakeslee and the Phillips Degreasers. No concentration as high as 10 parts per million (by volume) was found. This indicated that the local exhaust ventilation systems of both degreasers were functioning properly. A personal air sample, collected on the Roll-Coat Operator during the day shift on 12/11/75, gave a time-weighted average concentation of 90 parts per million (by volume) for methyl Isobutyl ketone in workroom air. Spot air samples, collected both forenoon and afternoon on this same day, had indicated 100 ppm (the 08HA TLV) as the concentration at the time of each sample. Additional shift length air samples are needed here to better evaluate the concentrations of both MIBK and toluene to which this operator is exposed. I greatly appreciate the courtesies extended to me during my visit. If I can be of further assistance, please let me know. Very truly yours. E. 0. Brown Industrial Hygienist BGB/eg Enclosures ucc 062370 Location Mix Screener Total Oust and Fume UNION CARBIEE CORPORATION Battery Products Division Red Oak, Iowa December 10-11, 1975 Concentration mg/M3* 1.93 Mix Screener 1.44 No. 5 Cramic Molding Machine Operator No. 5 Cramic Molding Machine Operator Operator on Finishing Line 2.88 1.49 0.06 Remarks Personal Sample, 12/10/75, A.M. 3 hrs., 36 min. Personal Sample, 12/10/75, P.M. 2 hrs., 56 min. Personal Sample, 12/10/75. A.M. 2 hrs., 45 min. Personal Sample, 12/10/75, P.M. 3 hrs., 38 min. Personal Sample, 12/11/75, A.M. & P.M. 6 hrs., 5 min. * The threshold limit value for carbon black is 3,5 milligrams per cubic meter of workroom air (06HA-1975). No more than 5-10 of the above total dust and fume should be acetylene black. .r ^ rjeSfti Vinyl Chloride Monomer UNION CABBIES CORPORATION Battery Products Division Red Oak, Iowa December 10-11, 1975 Location On person of extrusion machine operator VCM xrosi* 0.05 Remarks 12/10/75, A.M. & P.K 6 hrs., 56 * The current OBHA standard for vinyl chloride monomer In workroom air is 1 part per million (by volume) as an 8-hour, time-weighted average concentration. ucc 0t>23?2 Manganese UNION CARBIDE CORPORATION Battery Products Division Red Oak, Iowa December 10-11. 1975 Location Mix Screener Manganeme g/M3 0.32 Mix Screener 0.28 No. 5 Cramie Molding Machine Operator No. 5 Cramie Molding Machine Operator 0.35 0.25 Remarks Personal Sample 12/10/75, A.M. 3 hrs., 3$ min. Personal Sample 12/10/75, P.M. 2 hrs., 56 min. Personal Sample 12/10/75, A.M. 2 hrs., U5 min. Personal Sample 12/10/75, P.M. 3 hrs., 33 min. * The threshold limit value for manganese in workroom air is 5 milligrams per cubic meter (OSHA-1975). This is a celling value, not to be exceeded. ucc 062373 Location Mix Bcreener Arsenic UNION CARBIDE CORPORATION Battery Products Division Red Oak, Iowa December 10-11, 1975 Arsenic mg/M^* < 0.001 Mix Bcreener No. 5 Crsmlc Molding Machine Operator So. 5 Cramie Molding Machine Operator ^ 0.001 < 0.001 <10.001 Remarks Personal Sample 12/10/75, A.M. 3 hrs., 36 min. Personal Sample 12/10/75, P.M. 2 hrs., 56 min. Personal Sample 12/10/75, A.M. 2 hrs., 45 min. Personal Sample 12/10/75, P.M. 3 hrs., 38 min. * The threshold limit value for arsenic in workroom air Is 0.5 milligrams per cubic meter (OSHA-1975); however, HI06H has recommended that this TLV be lowered to 0.002 og/M This is due to the discovery of Increased lung cancer deaths among arsenic workers at Dow Chemical Co. and Allied Chemical Corp. Lead UNION CAKBIEE CORPORATION Battery Products Division Red Oak* Iowa December 10-11, 1975 Location Operator on Finishing Line Lead mg/M3* O.OOU Remarks Personal Sample, 12/11/75, A.M. & P.M. 6 hr8., 5 min. * The threshold limit value for lead In workroom air Is 0.2 milligrams per cubic meter. t Perchlorethylene UNION CARBIEE CORPORATION Battery Products Division Red Oak, Iowa December 10-11, 1975 Location Breathing level in aisle beside snalll Phillips Degreaser Breathing level in aisle beside large Blakealee Degreaser Perchlore thylene ppm* <10 .10 Remarks P.M. 12/10/75 P.M. 12/10/75 * Bie threshold Unit value for perchlorethylene in workroom air is 100 parts per million (by volume) (OSHA-1975) 062376 Methyl Is butyl Ketone UNION CAHBIEE CORPORATION Battery Products Division Bed Osk, Iowa Dec^ber 10-11, 1975* Location Paint Room On person of roll-coat operator MIBK 90 Near center of room 100 In corner by roll-coating operation Bear center of roan 100 100 In corner by roll-coating operation 100 Rosaries Personal Saaple 12/11/75, A.M. & P.M. Spot Sample, 12/11/75, A.M. Spot Saaple, 12/11/75, A.M. Spot Sample, 12/11/75, P.M. Spot Saaple, 12/11/75, P.M. * Tbe threshold Halt value for MIBK In vorkrocn air is 100 parts per Million (by volune) (OSHA-1975). Mr. J. Alspaugh Battery Products Division P. 0. Box 671 St. Albans, Vermont 05U78 January 23* 1976 Medical Department Mr. J. C. Brouillette Mr. R. Christie/Mr. T. Burke Mr. H. M. Boleambe Mr. P. J. Kennedy Dr. J. J. Welsh/Dr. K. 8. lane Dear Mr. Alspaugh: On January 7, 1976 air samples were obtained at case molding and 0 ring molding to determine what air-borne concentrations of vinyl chloride might be present from the use of PVC resins in these items. At the case molding unit, the operator wore a personnel sampler during both the morning and afternoon segments of the shift. In neither case were vapors of vinyl chloride detected. Operating difficulties were experienced with the 0 ring mold and two samples obtained at this location in the morning Indicated 0.18 parts per million of vinyl chloride. The unit did not operate in the afternoon. Prom these results and those taken in May of 1971*, it is Indicated that employees at these operationssare not being exposed to levels of vinyl chloride requiring further action. In the future, additional samples may be obtained to ascertain that concentrations remain at these levels or lower. If you have any questions, please let me know. Very truly yours. L. J. LaFrance Industrial Hygienist * r Mr. D. Blankenship Battery Products hivision Bdgevater Laboratory Box 6056 Cleveland, Ohio UblOl Mr. T. Burke Dr. K. S. Lane January 9, 1976 Medical Department Dear Mr. Blankenship: Would you please analyze the enclosed samples numbered SI, S6, SA2 and BA3 for total vinyl chloride monomer and report the results to me. lhey are from the St. Albans Plant. Blanks. Very truly yourp, L. J. LaPrance Industrial Hygienist LJl/eg Bnc. ,,ucc 062379