Document M4L4DMKKDMxVdLbjO52y3BOmL
industrial hygiene survey OF
CHINA GULF PLASTICS CORPORATION
August 1976
by Robert T. Cheng, Ph.D., p. E,
^^0 09
Uj
--C-
'~S
\
&
*4
4V
CUSAROSS 00562
5
19. CGPC's Industrial Hygiene Laboratory should have a larger work area and, most importantly, should be maintained orderly and clean. CGPC should periodically send parallel samples to Gulf's Health Sciences Laboratory for comparative analysis,
20. The Taoyuan Plant is a much healthier workplace compared to the Toufen General Plant. A few suggestions are made to reduce hazards of noise, epoxy, and dusts of lead, barium and cadmium.
21. Four air samples collected from Kaohsiung's TVCM Plant showed workplace VC concentrations ranged from 5 to 21 ppm. This should be reduced by the same "Search and Secure" technique suggested for the Toufen General Plant.
22. Based on odor threshold of ethylene dichloride (EDO), the TVCM Plant workplace EDC concentrations are over 100 ppm at many locations. In the U.S., the exposure standard for EDC will be lowered to 5 ppm, with ceiling restriction at 15_ppm. A conscientious effort should be made at TVCM to reduce EDC emissions from various leaks and from the many intentional release sources such as pressure relief valves and steam blow-down points.
Many thanks to Messrs, W. Shyeh, K. Yu, C. C. Yang, Tsung-Lin Chow, Ed Lu and other members of the Plant management for their courtesies and cooporation. Special thanks to Ed Lu and O. H. Huang for their assistance in carrying out the survey work.
M*U|`
i-
CUSAROSS 00563
mm
cqpc
# & ?h M & /]. ^
m ^ -i
&hina (^nL ^filasllcs (Horporalion
GENERAL PLANT, NO, 1 HWA-HSIA KD. TOU-FBN. MIAO-LI TAIWAN 350 REPUBLIC OF CHINA
James O* JackGcn Ph, O* Laboratory Director Health Sciences Laboratory Uedical Department Gulf Oil Corporation P. 0. Box 3240 Pittsburgh PA 15230
U# S* A*
May 13, 1976
TEL : 23191
23192 23193 23194
Dear Jims
From your correspondence of September 4, 1973 (reft 100 B 3-3) we have found out the gas selector setting of VCU far our OVA-113 B is at 614* However for other organic vapors no informations available at my hand*' Would you please contact Ur* Bill Hood* Century, concern ing the ges selector setting numbers for OVA-113 B model* Please also, Ur. Bill how can we update our CWA-93 B to the status /of 118 B end what is the charge*
I oj>M-
We are in shortage of the BCC Developing Vials with Teflon lined Septum caps* Would you please ask Ur. Rich Guild* HOC * to give me a quotation of ordering 50 vials by air freight Taipei*
Thank you very much
Sincerely Tours Bdwsrd K* Lu
.
CUSAROSS 00564
CENTURY SYSTEMS CORPORATION
P 0 BOX 133 7 ARKANSAS CITY. KANSAS 67005 TELEPHONE 316 / 447-3311 TWX 910-740-6740
Mr. C. Y. Peng Manager, Engineering Dept. China Gulf Plastics Corp. P. O. Box 22144 China Gulf Plastics Building 3, Tun I-Iwa S. Rd, Taipei, Taiwan, R, O. C,
Dear Mr. Peng:
*
This letter is a first of many which will be sent tu you, periodically, to assist in the application and maintenance of your Century products. Three important maintenance notes have been enclosed lor your immediate useage.
Three News Releases are enclosed to give you a sneak preview of Century's new products which will be introduced for the first Lime at the AlHA Con ference in Atlanta, May 18 thru 20, Booth No. 35 and 36.
Portable Air Sampling Pump, CAP-130, an electronically timed posi tive displacement pump with high accuracy and Low cost. Programmed Thermal Desorbcr. PTD-132, provides fully automalic desorption and automalic sample injection into a Gas Chromatograph. Air Sample Collector Tubes, engineered wild a sealing i'lare on one end and with a varieLy of sorbent packing or blanks loi selected tilling.
Other new products and accessories include; GC calibrators, GC columns, OVA Sample Dilutor and (on-line) syringe injec ion fixtures.
Our rep will soon be delivering a note book to you, which includes general catalogs on Century's products, price lists, technical notes, maintenance notes, application notes, calibration procedures, monitoring techniques and information concerning present and proposed regulations. MaLerial will be sent from time to time to keep you updated.
If you are planning to attend the AIHA Conference, we invite you to be our guest at the Century Hospitality Suite, open from 6:00 to 10:00 p.m. Sunday, Monday and Tuesday, Room 901 in the Marriott. You are also invited to attend presentations on the "TOTAL SYSTEMS APPROACH TO VAPOR MONI TORING", which Century will be conducting during the conference.
Yours truly,
V AM:do Enclos u res May 3, 1976
Victor A. .viatcison, j r. National Sales Manager
*1 # % Kf It { m
GENERAL PLANT, NO. 1 HWA-HSIA RD. TOU-FEN, MIAO-H TAIWAN S50 REPUBLIC OF CHINA
TEL : 23191 23192
23193 23194
Att. Victor A. Mattison Jr. Hoclonal Sales Manager Century Systems Corporation P. O. Box 133 Arkansas City, Kansas 67005
U, S* A.
Datai July 25, 1976 Ref i CGFC-ISKO-004
Door Ur# Uattieont
Your Ueiy 3th letter to Ur* C* Y* Peng --- Manager of Engineering Dept, was transferred to Re at the beginning of July. We thank you very much for furnishing ua aaae Isfoma* tians about Portable Air Sampling Pump -- CAP -- 130, Programed Thermal Deaorber, PTD-133, Air Sampling collector tubes & maintenance notes CM-63, CH-66* CM-67.
1 have two sets of CWA-oodcl 53 B & model 110 B in my office. Our mainly purpose is to monitor VCU and solvent concentrations at the working areas.
Recently we heard that Century Co* can update OTA-99 B to the Status of 119 B from Gulf Oil Corp. Health Science Laboratory at Pittsburgh. If that Is true please let ua know the expanses.
Besides please check whether a gas selector setting list available of CWA-118 B far orgsnlO vapors other than VCM (setting at 914) and CH* (setting at 300)* VCU & CH^ were the only two informations available at my hand*
If you have more detailed catalogs fCC CAY-130* PTD-133 and sampling collecting tubes please send then to me*
In your latter you mentioned your Rep* will delivering a note book to us, which includes general catalog <m Century's
Products, price Hats, technical ioteo, maintenance note, application notan, calibration procedures, monitoring techniques etc. I would like you to arrange those informations directly mailing to ne at the Plant*
Thank you very much*
Your Truly,
cc> Ur* C* Y. Peng-Taipei
Kdward K. L. KU Manager, Safety & Hygiene Office, Taa-Pen Pactary China Gulf Plastics Carp*
<
- X. S? Uf
iff fEL/> s] #1 ^ &
CHINA GULF PLASTICS CORPORATION TOUFEN PLANT
if\ lift ^ -- -O' $
PURCHASE REQUISITION-SPECIAL
4*. It Xf St ft it M T fl -S- J<I a *j ft: Purchasing Department Please Purchase the lionis Listed Below;
.....
itWS-ttty
PR NO.
a&
Date
10/23
t>!ty *9tt4
^
item
n
. ,, *+ t>, f, ft 7, !<. ft TO NO, j Item Ns. QCt]j ^o.i Descripwon/'q'.-ofic itutm
ft vr
quantity
,
*<i i*
M
Unit, Keqtiui
*'
PATR
UF.Q'U
w
FOLI.OW-UP REMARKS
19 .76
1* Cot Ho* 226-02-100 Developing Vials with
Pfcg j
Teflon lined septum etpa
o04
;-;.......................................................
2* Cot Ho* 323-3-6 six FAK Charcoal tubo holder&
. Complete vith coiir.eciing tubing
a,
an
..............................................
.
II] i* Sporo ports for BCC model
Supplier* Environment!
UsHe 222-3 personal pump
Conpllcnco Ccrp* P0. Bern 55
Venotia FA-15367 U.8.A,
H -!t
rn X-1*1
to fll
u TO BE CAR
Approved by;
1 IN The Budget . Noted by-.
Checked by*.
Requisitoned by:
RIED
P T' f # f*) Not Ln The Budget1
-\
IN STOCK*
p JW
Dote:
; ^ k
i PUnt Manager
0M
Dote:
fr -il
Accounting Dept
HW
a xn
Unit*:
t A J,7 itt ta k
Date;
ft IT Tt* 04 it Jt.
Production Controller Invty. Control-Sup
7'\. I n 1 ' ufvf
a us) a ix ' it df*
DeptQIead Section Chief
n- ft
For Stock
ntr >*
On Case-to-
Case Basis
| CGPC Form No. 0 0 3
t c3W : it tt" # ' n
QUADRUPLICATE-REQU1S1 riONING DEPARTMENT FILE
# 7L Ay i Ilf ft t AS S] m ft m <&
CHINA GULF PLASTICS CORPORATION TOUFEN PLANT % -f- -- 'i'N ^
PURCHASE REQUISITION-SPECIAL a ft Xt fit 4*. C* T X'l & 'f 0 i, ft :
_T'u: Purchasing Deparlment Please Purchase the Items Listed Below;
rrMr-rroj 'SEiitty ft
PO NO Item No. Code NO.i
ITEM
ft ft
Description/Spe eifiejt.ons
ft L QUANTITY
.II (i if
Unit, Raqtnd,
X *1 u XX DATE RF.Q'D
PR NO.
Ltf 10/23
,19 76
4* fi ft t
FOLLOW-UP REMARKS
1. AA Si*a RXCA3D recharjeabla battery for BCC modal 232-3 personal pump
i dm| one I , dozen
3* Cot* No* 226--01--100
charcoal tubes pkg of
100
Pkg
ft] Spare parts for BCC model
| 222-3 personal pump
Supplier! Environmental CcmpUaao* Ccrp. P.0*Bcm 55
_____Venatia PA* 15367 U. 6. A*
-i*
Approved by;
i unt-i*!
1 i w
IN The Budget ! Noted by;
nr.F. xm
Not In The Budget
fit *t Checked by:
it U
Requisitoned by:
TO BE CAR RIED
IN STOCK-
9W
Drtte
ak Plant Manager
aW
Datr*: _
$ T.
Accounting Dept
s
_Date.
k'l, 'i- tc k
Production Controller
aw
Date;
4 ti *r k
Ittvty. Control-Sup
>' A/
* U) K J ft f***
Dept Head Section Chief
ft For Stock
A
On Case-to-
Case Basis
CGPC Form No 00 3
Ho#:if # >11 QUADRUPLICATE-REQUISITIONING DEPARTMENT FILE
CUSAROSS 00567
A Ji ; $ # W m ft t ft'> s] *8 A
CHINA GULF PLASTICS CORPORATION TOUFRN PLANT
Ipf Ha- ^ ' `
^
PURCHASE REQUISITION-SPECIAL
am-v,*,
PR NO
it tf a 4 1* M T f'l * a ^ Er ; To: Purchasing Department Please Purchate the Items Listed Below;
Date^ 10/23 19 76
' tr ?-.(, '(iSSt^ '
<;
it It
PO NO. , Item N*. Code NO.,
ITEM
n
-6 W A <L t.V
Description/Specifications
tv f QUANTITY
^li In
Unit Rcqtnd
i r *ji
DATE RFQ'D
t It. X
FOLLOW-UP REMARKS
X* Battery 12V Bi*-Cad* Burnoee
<3> 201 |
ea.
2 Filter Charge(treated carbon)
lb* 3, Tubing,(3/3"K>si/16, wall ft*
1/4XD )
fo'JT
five ten
4* Optioal chamber assembly aas* one completeyith U*V. leny & .
ffl it
Usage
two photo cello Spare parte for J-W modal UV-2 Uercury vepor sniffer
SupplieriBechgrach Xnatrument Co* 625 Alpha Drive RXDC Xnduntrial perk Pittsburgh
Approved by*.
#-
i
IN The`Budget Noted by
T-A #-!*>
Not In The Budget
A f.
hint Minuter
BM Date:
it
Accounting Dept
CGPC Form No. 0 0 3
fi P
Pate:
A '1-1 a k Production Controller
lit tt Checked by:
~ FA.1^33 U.'S. A
Requmtoned by,
TO BE CAR RIED
IN STOCK.
np
Date,
nk
Invty. Control-Sup
-\
\
& (to) k -J k Dept Head Section Chief
n* a-
For Stock
NT A
On Case-toCase Basis
f.t.'tj c, U > n
QUADRUPLICATE REQU1SI HONING DEPARTMENT FILE
I \J i CLt f4 -Ls&*>
CUSAROSS 00568