Document M4G8JZ7jvoRqEaKdgmyQDrJ0y

f Heaters, Water The Whitlock Coil Pipe Company Manufacturers and Engineers Atlanta, Ga. Houston, Tex. HARTFORD, CONN. New Haven, Conn. Rochester, N. Y. 111 |IL(lQlj(|C.lir^Baltimore,- Md. Indianapolis, Ind. /S)fffl fil fji<siB) Charlotte, N.C. Jacksonville, Fla. ' umM/ILbJI |l| New Orleans, La. St. Louis, Mo. Mexico City, Mexico San Antonio, Tex. Cincinnati, 0. Kansas City, Mo. 11011 II* II* Iggy^syOmaha, Nebr. San Francisco, Caiif. Cleveland, 0. Lee Angeles, Calif. Dallas. Tex. Memphis, Tenn. HEATERb Pittsburgh, Pa. Portland, Ore. Seattle, Wash. Tacoma, Wash. Denver, Colo. Manufacturers of and Sales Agents for Whitlock Heaters in Canada--Darling Bros., Ltd., 120 Prince St., Montreal See Telephone Directory for Local Address Whitlock type "K" storage heaters are manufactured in both horizontal and vertical types. The table shows sizes of the horizontal heaters only. We will gladly furnish dimensions of horizontal heaters and vertical heaters upon request. That ~ this type of heater is of jarticularly sturdy construction is evidenced by the increasing number of prominent engineers and architects who are specifying their use in all types of buildings, including many of the largest and finest buildings constructed. Whitlock Type K Storage Heaters, Horizontal .SHELLS To be used with Type K Heating Section Shell Prices include Cradle. Manhole I 1**15* ; HEATING SECTIONS " Capacity based on Heating from 40 to 180 with Steam at 0 lbs. pressure. For other tempera tures and Steam Pressures see Bulletin No. 27 Gallons Diaro- Number One *eter Filling of Shell Length Thick- Thick- Weight nett new Shell of Shell of Head Shell Number Gallons & Maximum Size Steam Pipe Inches Smallest Shell into which Section will Fit Inches Weight Entire Heating Section Lbs. 1 65 18 2 80 18 3 118 24 4 141 24 5 164 24 6 185 30 7 220 30 8 255 30 9 '290 30 10 365 36 II 420 36 12 475 36 13 525 36 14 575 42 15 720 42 16 .860 42 17 1000 42 18 950 48 19 1140 48 20 : 1310 48 21 1480 .48 22 1190 54 23 1430 54 24 1670 54 25 1900 54 26 1420 60 27 1710 ' 60 28 2000 .60 29 2300 60 30 2460 72 31 2880 72 60 % y 72 % % 60 'A 72 1A %% 84 A 60 % %V, 72 'A 84 \A VV,t % 84 96 108 120 % 120 144 168 120 144 '%%X%%%%%A % % % % i <4 n Y>4t V<Ai A 168 % % 192 % Yt 120 V, 144 % 168 y 192 % n'n<44 120 % % 144 % 168 % % 192 % % 144 % % 168 A A 400 450 600 700 800 750 850 950 1050 1300 1450 1600 1800 1850 2150 2500 2900 2850 3250 3700 4100 3230 3700 4200 4700 4300 4900 5600 6200 5700 6400 H0 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 HI1 HI2 HI3 HI4 H15 H16 H17 HI8 HI9 H20 H21 H22 H23 H24 H25 H26 H27 H28 H29 H30 100 150 200 250 300 350 400 500 550 600 700 800 900 1000 1250 1500 1750 2000 2400 2600 3200 3600 4000 4400 4800 5400 6000 7000 8000 9000 10000 2 2 2 33</2A VA 33<%4 3% 3% 5 i3y., 5 5 5 .6 6 6 8 8 8 8 10 to 10 12 12 12 12 18k 48 18* 60 18* 72 18* 48 18* 48 16* 60 18* 60 18* 72 16* 72 18* 84 24* 60 18* 96 18*108 18*120 24* 84 24*108 24*120 30* % 30*120 30*132 36* 96 36*108 36*120 36x132: 36x 96 36x108 36x120 42* 96 42x 96 42x108 42x108 75 80 90 . 175 185 190 200 210 215 220 300 260 270 285 370 425 450 570 620 670 660 920 950 1020 1200 1300 1380 . 1950 2000 2300 2460 DIRECTIONS FOR USE--Select the use storage you require and combine its designating number with the number which designates the desired hourly output. Assuming a required storage of 1000 gallons (No. 17 shell 42 x 168) and a required hourly output of 1750 gallons (No. H16 Heating unit) you would specify a Whitlock Type K. No. 17H16. 704 The Whitlock Coil Pipe Company Heaters, Water WHITLOCK TYPE R INSTANTANEOUS HEATERS This type of heater is used extensively as an instantaneous heater in connection with a separate storage tank, as a swimming pool heater, as a hot water convertor for use with a heating system, as well as for various special conditions. Standard sizes of the multi-pass and 4 pass heaters are shown in the table. Dimensions on 2 pass heater will be furnished on-request. Standard Sizes, Capacities, Dimensions 'and Weights *= MULTI PASS. TEMP. RANGE 40 F. to 180 F. 4 PASS TEMP. RANGE 40" F. to 120" F. Size No. Diam- Size Size Capacity Lham- Size Size tloUT Length of Shell Water Conncc- Steam Connec- Weight Gallons Over-all per Length tions tions Hour eter of Shell Water Steam Weight. Conncc- Connec- tions tions 0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16. 17 18 18% 19 19% 20 21 22 23 24 25 25 60 150 200 250 300 400 500 600 800 . 1000 1250 1500 2000 2500 3000 4000 5000 6000 7000 8000 9000 10000 12500 15000 20000 25000 30000 15% 26% If, 4 4o% 52 61 74 59% 72% 59 71 89 74% 88% 'Ml 7% 78%. 94% 89 113 . 96 112 7 7 7 9% % v/l SB 12 12 12 15 15 17 17 17 20 20 20 26 26 26 26 30 30 36 . 36 y. /. Vi l 1 1 l'/ 1% iy. n pa 2 2 2Vz 2*A m 3 3 3 4 4 4 4 5 6 6 6 1 i'/. i% iyi 2 2 2'/i 3 3 3/i 3% 4 5 5 6 6 8 8 10 (0 10 10 12 12 14 16 18 20 90 125 160 280 325 250 300 , 325 350 575 645 760 870 1020 1035 1175 1420 1910 2185 2475 2800 3000 3220 3725 4125 4860 6350 7175 80 150 300 480 650 800 960 1350 1600 2100 2600 3300 4000 5300 6600 8000 10500 13300 16000 18500 21000 24000 26700 33300 40000 53300 66700 60000 ny, m 21% 4m, 24% 30% 353/, 433/4 55% 52 61 . 79 55% 65% 71 83 72% 92% SB 82*/, 73 92 83 95 7 7. 7 7 7 7 94 9% 9% 9% 12 12 12 15 15 17 17 20 20 : 20 26 26 26 30 30 36 36 '/4 1 | !% 2 2 2 2% 2% 3 3 3% 4 5 5 5 5 6 6 6 6 8 8 10 10 1 \Va 2 2 P 3 3 j'/2 .4 5 5 6 6 8 8 10 10 10 12 12 12 12 14 14 16 20 22 80 100 115 135 150 170 220 270 300 . 350 420 620 . 700 860 940 1070 1390 1580 2020 2230 2430 2800 3000 3480 4015 4600 . 6100 6900 Sizes 0 to 8 inclusive, have %* O. D. No. 18 B. W. G. Tubes^ r o. d. No. 17 B. W. G. Copper 0 to 10 inclusive, have %* O. D. No, 18 B. W. G. Copper lubes. Remainder have r O. D. No. 17 B. W. G. Copper Tubes. Whitlock Heat Transfer Equipment includes the following types of apparatus in addition to the Storage and Instantaneous Heaters shown above: Feed Water Heaters; Heat Exchangers; Fuel Oil Heaters; Superheaters; Condensers and Coolers for all kinds of liquids; also pipe coils of any kind of pipe or tubing, and Air and Ammonia Receivers. Additional information and quotations covering any of this apparatus will be gladly furnished upon request. Bulletins Nos. 25 and 40, issued during 1931, and therefore up-to-date, covering Type R and Type K heaters respectively, will be sent on request. They contain many useful tables, such as the ``Hot Water Fixture Capacity Table", tables on the rating of ``Hot Water Convertors", and so forth. Several' other bulletins, covering other types of Whitlock Heaters and Heat Ex changers, have been issued recently. A complete set will be a worth while addition to your file of engineering data. 705