Document M4G8JZ7jvoRqEaKdgmyQDrJ0y
f
Heaters, Water
The Whitlock Coil Pipe Company
Manufacturers and Engineers
Atlanta, Ga. Houston, Tex.
HARTFORD, CONN.
New Haven, Conn. Rochester, N. Y.
111 |IL(lQlj(|C.lir^Baltimore,- Md. Indianapolis, Ind.
/S)fffl fil fji<siB)
Charlotte, N.C. Jacksonville, Fla. ' umM/ILbJI |l|
New Orleans, La. St. Louis, Mo. Mexico City, Mexico San Antonio, Tex.
Cincinnati, 0. Kansas City, Mo.
11011 II* II* Iggy^syOmaha, Nebr.
San Francisco, Caiif.
Cleveland, 0. Lee Angeles, Calif. Dallas. Tex. Memphis, Tenn.
HEATERb Pittsburgh, Pa. Portland, Ore.
Seattle, Wash. Tacoma, Wash.
Denver, Colo.
Manufacturers of and Sales Agents for Whitlock Heaters in Canada--Darling Bros., Ltd., 120 Prince St., Montreal
See Telephone Directory for Local Address
Whitlock type "K" storage heaters are manufactured in both horizontal and vertical types. The table shows sizes of the horizontal heaters only. We will gladly furnish dimensions of horizontal heaters and vertical heaters upon request. That ~ this type of heater is of jarticularly sturdy construction is evidenced by the increasing number of prominent engineers and architects who are specifying their use in all types of buildings, including many of the largest and finest buildings constructed.
Whitlock Type K Storage Heaters, Horizontal
.SHELLS
To be used with Type K Heating Section Shell Prices include Cradle. Manhole I 1**15*
; HEATING SECTIONS
"
Capacity based on Heating from 40 to 180 with
Steam at 0 lbs. pressure. For other tempera
tures and Steam Pressures see Bulletin No. 27
Gallons Diaro-
Number One
*eter
Filling of Shell
Length Thick- Thick- Weight
nett
new
Shell of Shell of Head Shell
Number
Gallons &
Maximum Size
Steam Pipe Inches
Smallest Shell
into which
Section will Fit Inches
Weight
Entire Heating Section
Lbs.
1 65 18
2 80 18
3 118 24
4 141 24
5 164 24
6 185 30
7 220 30
8 255 30
9
'290
30
10 365 36
II 420 36
12 475 36
13 525 36
14 575 42
15 720 42
16 .860 42
17 1000 42
18 950 48
19 1140 48
20 : 1310
48
21
1480
.48
22 1190 54
23
1430
54
24 1670 54
25 1900 54
26
1420
60
27 1710 ' 60
28
2000
.60
29 2300 60
30 2460 72
31
2880
72
60 %
y
72 %
%
60 'A 72 1A
%%
84 A
60 %
%V,
72 'A 84 \A
VV,t
% 84 96 108 120 % 120 144 168 120 144
'%%X%%%%%A
% %
% %
i <4 n Y>4t V<Ai
A
168 %
%
192 % Yt
120 V,
144 % 168 y 192 %
n'n<44
120 %
%
144 %
168 %
%
192 %
%
144 %
%
168 A
A
400 450 600 700 800 750 850 950 1050 1300 1450 1600 1800 1850 2150 2500 2900 2850 3250 3700 4100 3230 3700 4200 4700 4300 4900 5600 6200 5700 6400
H0 H1 H2 H3 H4 H5 H6 H7 H8 H9 H10 HI1 HI2 HI3 HI4 H15
H16 H17 HI8
HI9 H20 H21 H22 H23
H24 H25
H26 H27 H28 H29 H30
100 150 200 250 300 350 400 500 550 600 700 800 900 1000 1250 1500 1750 2000 2400 2600 3200 3600 4000 4400 4800 5400 6000 7000 8000 9000 10000
2 2 2
33</2A
VA 33<%4
3% 3% 5
i3y.,
5 5 5 .6 6 6 8 8 8 8 10 to 10 12 12 12 12
18k 48 18* 60 18* 72 18* 48 18* 48 16* 60 18* 60 18* 72 16* 72 18* 84 24* 60 18* 96 18*108 18*120 24* 84 24*108 24*120 30* % 30*120 30*132 36* 96 36*108 36*120 36x132: 36x 96 36x108 36x120 42* 96 42x 96 42x108 42x108
75 80 90
. 175 185 190 200 210 215 220 300 260 270 285 370 425 450 570 620 670 660 920 950
1020 1200 1300 1380 . 1950 2000 2300 2460
DIRECTIONS FOR USE--Select the use storage you require and combine its designating number with the number which designates the desired hourly output. Assuming a required storage of 1000 gallons (No. 17 shell 42 x 168) and a required hourly output of 1750 gallons (No. H16 Heating unit) you would specify a Whitlock Type K. No. 17H16.
704
The Whitlock Coil Pipe Company
Heaters, Water
WHITLOCK TYPE R INSTANTANEOUS HEATERS
This type of heater is used extensively as an instantaneous heater in connection with a separate storage tank, as a swimming pool heater, as a hot water convertor for use with a heating system, as well as for various special conditions.
Standard sizes of the multi-pass and 4 pass heaters are shown in the table. Dimensions on 2 pass heater will be furnished on-request.
Standard Sizes, Capacities, Dimensions 'and Weights
*=
MULTI PASS. TEMP. RANGE 40 F. to 180 F.
4 PASS TEMP. RANGE 40" F. to 120" F.
Size
No.
Diam- Size
Size
Capacity
Lham- Size
Size
tloUT
Length
of Shell
Water Conncc-
Steam Connec-
Weight
Gallons Over-all per Length
tions tions
Hour
eter of Shell
Water Steam Weight. Conncc- Connec-
tions tions
0
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16. 17 18 18% 19 19% 20 21 22 23 24 25
25 60 150 200 250 300 400 500 600 800 . 1000 1250 1500 2000 2500 3000 4000 5000 6000
7000 8000 9000 10000 12500 15000 20000 25000 30000
15% 26% If, 4
4o%
52 61 74 59% 72% 59 71 89 74% 88% 'Ml
7% 78%. 94% 89 113 . 96 112
7 7 7 9% %
v/l
SB
12 12 12 15 15 17 17 17 20 20 20 26 26 26 26 30 30 36 . 36
y.
/. Vi l 1 1
l'/ 1% iy. n
pa 2 2 2Vz 2*A
m 3 3 3 4 4 4 4 5 6 6 6
1
i'/. i% iyi 2
2 2'/i 3 3 3/i 3% 4
5 5
6 6 8 8
10
(0 10 10
12 12
14 16 18
20
90 125 160 280 325 250 300 , 325 350 575 645 760 870 1020 1035 1175 1420 1910 2185 2475 2800 3000 3220 3725 4125 4860 6350 7175
80 150 300 480 650 800
960 1350
1600 2100
2600 3300 4000 5300 6600 8000 10500 13300 16000 18500 21000 24000 26700 33300 40000 53300 66700 60000
ny, m
21% 4m,
24% 30% 353/, 433/4 55% 52 61 . 79 55% 65% 71 83 72%
92% SB
82*/, 73 92 83 95
7 7. 7 7 7 7
94
9%
9% 9% 12 12 12 15 15 17 17 20 20 : 20 26 26 26 30 30 36 36
'/4
1 |
!%
2 2 2
2% 2% 3 3 3% 4 5 5 5 5 6 6 6 6 8 8 10 10
1 \Va 2 2
P
3 3
j'/2 .4
5 5 6 6 8 8 10 10 10 12 12 12 12 14 14 16 20 22
80 100 115 135 150 170 220 270 300 . 350 420 620 . 700 860 940 1070 1390 1580 2020 2230 2430 2800 3000 3480 4015 4600 . 6100 6900
Sizes 0 to 8 inclusive, have %* O. D. No. 18 B. W. G.
Tubes^
r o. d. No. 17 B. W. G. Copper
0 to 10 inclusive, have %* O. D. No, 18 B. W. G. Copper lubes. Remainder have r O. D. No. 17 B. W. G. Copper
Tubes.
Whitlock Heat Transfer Equipment includes the following types of apparatus in addition to the Storage and Instantaneous Heaters shown above: Feed Water Heaters; Heat Exchangers; Fuel Oil Heaters; Superheaters; Condensers and Coolers for all kinds of liquids; also pipe coils of any kind of pipe or tubing, and Air and Ammonia Receivers.
Additional information and quotations covering any of this apparatus will be gladly furnished upon
request.
Bulletins Nos. 25 and 40, issued during 1931, and therefore up-to-date, covering Type R and Type K heaters respectively, will be sent on request.
They contain many useful tables, such as the ``Hot Water Fixture Capacity Table", tables on the rating of ``Hot Water Convertors", and so forth.
Several' other bulletins, covering other types of Whitlock Heaters and Heat Ex changers, have been issued recently. A complete set will be a worth while addition to your file of engineering data.
705