Standard Oil Co. of Texas El Paso, Texas THE M. W. KELLOGG COMPANY Job Number Class Page Dated Revised 5064 "N-l" 1 of 3 4-26-51 `5-28-51 (R-l) JOB SPECIFICATION THERMAL INSULATION DESIGN I. SCOPE A. This specification designates the extent of insulation, the thickness required and the type of insulation. B. The fireproofing of structural steel .and vessels is also covered in this specification. II, INSULATION FOR HOT EQUIPMENT A, General 1. All vessels and piping which have a normal operating temperature over 150F. shall be insulated to conserve heat unless a loss' is desired. 2. Surfaces which are normally 150F. or less shall have insulation if it is required for process stabilization. The thickness shall depend on conditions. 3. Surfaces which are hotter than 150F. which are so located as to be hazardous to personnel but which would not otherwise be in sulated, shall be protected with insulation, railings or screens. 4. Piping insulation shall be indicated on the Flow Diagram Nomen clature and equipment insulation on the Equipment Insulation Schedule. A Bill of Material for piping insulation shall be given on each M. W. Kellogg Individual Pipe Line Drawing. B. Vessels, and Piping over 36" in Diameter 1. The term "vessel" shall apply to any apparatus such as a tower, tank drum reactor or heat exchanger. 2. The major insulation shall be block form. Plastic insulating cement, l/8" thick, shall be applied over the block insulation. CHEV BB 0000700 Job Number Class Page Dated 5064 N-1" 2 4-26-51 INSULATION FOR HOT EQUIPMENT (Cont'd.) B. Vessels, and Piping over 36" in Diameter (Cont'd.) 3, Surfaces to which block insulation is not readily applicable may be insulated with plastic insulation. 4. The thickness of insulation for heat conservation shall be 1 1/2". This does not include the l/8" rirv thickness of insulating cement, nor the 1/4" wet thickness of weathercoating-. C. Pumps. Turbines and Compressors 1. Neither pump casings nor turbines are to be insulated except the compressor turbine, which shall be insulated by the manufacturer. D. Piping, 36" 0. D. and Smaller 1. The insulation shall be molded, sectional or segmental 85 per cent Magnesia pipe covering. Only "Standard" thickness shall be used. 2. Lines carrying steam which is not normally flowing, such as fire steam or steam tracing lines shall be insulated for the tempera ture of saturated steam at line pressure. 3. Steam traced lines shall be insulated for the temperature of the line. 4. Steam snuffing lines shall not be insulated beyond the last block valve. 5. Steam condensate lines shall be insulated except where condensate is being discarded. 6. Any uninsulated line which joins an insulated line shall be insul ated for three feet from the junction or to a block valve which is less than three feet from the junction. The thickness of the in sulation shall be the same as tnat of the insulated line. 7. 45 lb. asbestos roofing felt shall be used to weatherproof the in sulation of all outdoor and indoor lines. 8. Generally, no lines which are buried underground shall be insula ted. Doping with "Somastic" where required,, shall be in accordance with the Job Specification, Class "LC". 3HEV BB 1000701 Job Number Class Page Dated Revised 5064 mi;-ib 3 4-26-51 . 5-28-51 (:U t 113 . INSi.'LATIOH FOR COLD EQUIPMENT A. General 1. All refrigerated equipment shall be insilated according to The M. V. Kellogg Specification P30F, with Fcamglas, 2" thick. IV. FIREPROOFING A- Structural Steel 1. Structural members directly supporting hydrocarbon vessels shall be fireproofed on all sides up to tne point of load application. All other structural member3 shall be fireproofed at least 20 ft. above grade if their failure during a fire could be expected to cause rupture of any hydrocarbon lines, vessel, etc.. Secondary bracing members and supports for elevated walkways, stairs, and platforms need not be fireproofed. Pipe supports included in the above description snail be fireproofed except for the top flange of the horizontal member. B. Vessel Skirts 1. Skirts of vessels containing hydrocarbons shall be firepr'oofed. DESIGNATION OF INSULATION A. U s; s ( 1. The several uses of insulation shall be designated as follows: Type 1. Full Heat Conservation Type 2. Over Steam Tracing with Dangle Parallel Tracer Type 2D, Over Strajn Tracing with Spacer Blocks Type 2D. Over Steam Tracing with Single Tracer, Doubled Back Type 2S. Over Steam Tracing with S^ral Tracer Type 3. Operators' Protection Type 4. Fire Protection Type 5. Type 6, Anti-Sweat Type 7. Refrigeration Conservation Typo 8. Over Steam Jacketing CHEV BB 0000702