Document Ly6awad85vro6j94388MoEmd

FILE NAME: Rogers Corporation (ROG) DATE: 1981 ROG053 DOC#: ROG053 DOCUMENT DESCRIPTION: Environmental Engineering Report - GLP Blender Clean Out Operation - Exposure Monitoring My* ENVIRONMENTAL ENGINEERING REPORT C o n fid en tial FILE NUMBER: M M D-81-4 REPORT DATE: 8/20/81 A F F E C T E D GROUP; MMD SURVEY DATE: 7/6/81 SUBJECT; G LP B lender Clean Oat O peration - Exposure M onitoring ACTION: AJD ontje RJM ikulak IN F O ; WAH CAB CGM LCHaack MKupsaw W JW hifeley TLSle g e r PURPOSE: T his study w as conducted to determ ine w orker exposure to a ir contam inants during the clean out p ro c e ss on the G L P F inal B lender, D uring th is o p eratio n , the em ployee clim bs into the b le n d er and chips out solidified m a te ria l on the in te rio r w alls of the b len d er. SUMMARY; D ust exposure during the clean out p ro cess is w ell in e x c e s s of the c u r r e n t OSHA P E L , C urrently used resp ira to r protection is not co n sid ered adequate for the m easu red d u st levels* Suggestions to reduce dust exposure a r e p re s e n te d . P ro m p t action by the division is recom m ended. M onitored by: C Jijdrter Analyzed by: C JfP o rter Env. Eng, M gr. Appv. D ate: 7/6/81 D ate: 8 / 1 0/81 D ate; 8 - S - 8 1 Rogers-Gough 01419 ~Z~ PROCEDURE A sbestos M onitoring NIOSfl #239 - C o lle c tio n oi> filte rs * a n a ly s is by P h a se C o n tra s t M icroscopy* N uisance Dust M onitoring C ollection on PVC f ilte rs , G ra v im e tric a n a ly sis. RESULTS T able 1 A ir M onitoring Data - MMP 7 /6 /8 1 Sam ple # Ope ration Em ployee Sam ple Tim e Contam inant Concentration M813001 C LP B lender LLoyd B arnes 8 m A sbestos Clean Out M8130O2 it M 813003 fi n 4 m A sbestos it 7 m T o ta l N uisance D ust Im possible to C oun^Fil ter O v erlo ad ed 2.31 f/c c 4307 m g/m ^ ^ (A) Q u estio n ab le r e s u lt due to the e x tre m e ly sm a ll sam ple volum e req u ired to avoid fille r p articu la te o v erlo ad . (B) M icroscopic an aly sis of d u st by P o larise d Light M ic ro scopy showed: glass fiber* w ollastonite, am orphous silica* oolite* re sin , all present* definite asb esto s fib ers. C u r r e n t OSHA P E L *s A sbestos: 2 . 0 f / c c 8 h o u r TWA 1 0 .0 f / c e 15 m P e a k N uisance Dust: ISm g /m ^ - T o ta l D ust 8 hour TWA 5 m g/jrr* - R e s p ir a b le D u st 8 h o u r TWA Rogers-Gough 01420 -3 ~ ( DISCUSSION The data, in T able #1 in d icate w o rk e r exp o su re lev els a r e g re a tly in e x c e s s of the c u r r e n t OSBA n u isa n c e d u st P E L d u rin g the b le n d e r clean out p rocess* A sb esto s ex p o su re is d ifficu lt to quantify because of the larg e e x c e s s of d u st which in te rfe re s with the fiber counting procedure* S teps taken to reduce d u st exposure should also low er asb esto s levels* The clean out p ro c e s s n o rm ally re q u ire s one or two sh ifts to com plete* It should be noted that only a sh o rt tim e period, which o ccu rred approxim ately m idw ay through the clean out p ro c e ss, w as sam pled* In addition, the em ployee involved in this operation ac tu ally spends m o re tim e outside the blender (p rep arin g him self before en terin g and cleaning h im self a fte r) than inside* Still the m agnitude of the exposure lev els while inside the b len d er causes the e ig h t h o u r TWA e x p o s u re to be in e x c e s s of the OSBA PEL* A r e s p ir a to r w as being w orn by the em ployee w hile inside the b len d er, but an organic vapor ca rtrid g e with a fe lt p articu late filte r which was being used is not considered adequate for this situation. The I felt was com pletely p en etrated by d u st a fte r only seven m inutes in sid e the b le n d er* T he e m p lo y e e 1 sa fe ty g la s s e s and face w ere com pletely covered w ith d u st upon leaving the b len d er. E a r m uffs w ere being w orn to reduce noise exposure* The division should a c t to reduce dust exposures during this clean out process* P o ssib le techniques to acco m p lish this include; 1* R erouting ventilation on blender during cleanup so that fre sh a i r m akeup e n te rs through top and is exhausted through bottom thus pulling dust away from w orker, 2. Rigging a i r h am m er to elim in ate a i r sp ray blowoff inside blender w hich c re a te s fu rth er airb o rn e dust* 3* Im proved re sp ira to r protection* P re sen t dust exposures would re q u ire the use of a full face, high efficien cy , p r o tection* The A irstre a m sy stem by Racal ap p ears w ell suited f o r th is o p era tio n * The a i r su p p lied ,fA ir C ro w n " S y ste m would provide excellen t p ro tectio n , elim inate the problem of clogging filte rs and would probably re s u lt a m uch Rogers-Gough 01421 -4 -* fa ste r clean out process* F u rth e rm o re , this system could be adapted for use in oth er ex c essiv e dusty operations like baghouse m aintenance. E nvironm ental E ngineering can a s s is t in im plem enting the dust reduction program . /dec Rogers-Gough 01422 APFBIIDXK: #3 M r Sampling Data - Areas Hear Asbest Obtaining Materials Sample # Date Figure* Location Description Sample Time Contaminant Concentratior F853001 8/21/85 Fig. 1-A Area/404 Dryer Aisle 255 m Asbestos 0.004 f/cc F853002 8/21/85 Fig. 1-- B Area/Between 403&402 Driers 254 Asbestos 0.006 f/cc F853003 8/21/85 Fig. 1~D Area/302 Wet Machine 246 IB Asbestos 0.007 f/cc F853004 8/27/85 Fig. 4-F Area/Beater 154 m Rm. ,East Wall Asbestos 0.005 f/cc F853005 8/27/85 Fig. 5--G Area/Finishing Room 152 m Asbestos 0.004 f/cc F853006 8/29/85 Fig. 2-E Area/995 Line Back Side 366 m Asbestos 0.004 f/cc F853007 8/29/85 Fig. 1-C Area/10fc. From 360 m 304 Wet Machine Asbestos 0.003 f/cc F853008 8/29/85 Fig. 3-H Area/983 Mach. Left Side 361 m Asbestos 0.002 f/cc F853011 8/30/85 Fig. 5-- 1 Area/ Bldg.#21 Service Room 370 in Asbestos 0.004 f/cc F853009 8/29/85 A r e a / B l d g .#3 Third Floor 359 m Asbestos 0.005 f/cc P853010 8/30/85 Area/6th Floor Warehouse 382 m Asbestos 0.004 f/cc F854001 10/23/85 ----- Area/Pulp Shed 151 ro Barracuda Pulper Asbestos 0,04 f/cc *See attached map for area locations)* BOTES 1* Areas sampled requested by EMBulger 8/15/85. 2. H I O S H m e t h o d P & Cam 239 utilized. 3* departed values represent approximate fiber levels at the time of sampling. Significantly higher fiber levels may be caused by activity or air currents in the area* 4. 1 P A d o e s n o t r e c o m m e n d th i s t y p e of s a m p l i n g for p r i m a r y e v a l u a t i o n of asbestos containing materials. 10 Rogers-Gough 00336