Document LwjGx82qLxOBn6GN8eLkkrd
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 5
77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604
SUBJECT: FROM: THRU: TO:
CLEAN AIR ACT INSPECTION REPORT Infinity Natural Resources (INR) Goebeler Well Pad
Victoria Nelson, Environmental Engineer AECAB (MI/WI)
Sarah Marshall, Section Supervisor AECAB (MI/WI)
File
BASIC INFORMATION
Facility Name: Infinity Natural Resources (INR) Goebeler Well Pad
Facility Location: 150 Spring Rd NW Minerva, Ohio 44657 (40.643901, -81.098198)
Date of Inspection: August 29, 2022
EPA Inspectors: 1. Victoria Nelson, Environmental Engineer 2. Jacob Herbers, Environmental Engineer 3. Sasha Letuchy, Environmental Engineer 4. Manoj Patel, Environmental Engineer 5. Laura Neudorf, Environmental Engineer
Other Attendees: 1. Bill Veigel, Production Manager, INR 2. Larry Barr, Supervisor, INR
Contact Email Address: BVeigel@infinitynr.com
Purpose of Inspection: To assess compliance with the facility's Permit-to-Install and Operate, and the Clean Air Act
Facility Type: Oil and gas well pad
Regulations Central to Inspection: NSPS Subpart OOOO/OOOOa - Standards of Performance for Crude Oil and Natural Gas Facilities
Arrival Time: 14:00 EDT Departure Time: 14:45 EDT
Inspection Type: Unannounced Inspection Announced Inspection
OPENING CONFERENCE
Presented Credentials Stated authority and purpose of inspection Small Business Resource Information Sheet not provided. Reason: Not a small business Provided CBI warning to facility
The following information was obtained verbally from Bill Veigel and Larry Barr, unless otherwise noted.
Process Description: At the south well pad, an oil/gas/water emulsion is extracted from the formation through three wells that each flow into a sand trap, a gas processing unit (GPU), and a three-phase separator. From there, the oil/condensate is sent through a heater treater and then into three tanks, and the produced water is sent into three tanks. The tanks feed to two combustors, which are the primary emission control devices. At the north well pad, an oil/gas/water emulsion is extracted from the formation through seven wells that each flow into a sand trap, a gas processing unit, and a threephase separator. From there, the oil/condensate is sent through two heater treaters and then into six tanks, and the produced water is sent into three tanks. The tanks feed to four combustors, the middle two being the primary emission control devices. The gas is sent to pipeline for further processing.
Staff Interview: Facility staff said that they have 10 well heads, with wells 4H and 10H not yet producing. They said this site produces approximately 3,000 barrels per day. Wells 1H-3H are the oldest and produces less than the newer wells 5H-9H. Larry Barr stated that the valve (vertical pipe) on the south tank battery was emitting even when the valve was closed.
TOUR INFORMATION
EPA Tour of the Facility: Yes
Data Collected and Observations: EPA observed emissions from at least two combustors. With the FLIR camera, EPA inspectors observed emissions from a thief hatch, a conservation vent, and a valve on the South tank
Page 2 of 5
battery. There was also oily residue on the thief hatch. EPA noted strong odors while on the catwalk of the South tank battery.
Photos and/or Videos: were taken during the inspection.
Field Measurements: were not taken during this inspection.
CLOSING CONFERENCE
Provided U.S. EPA point of contact to the facility
Concerns: EPA had concerns about design and operation of the vapor capture and control systems at the facilities, which we discussed with INR representatives. EPA's concerns stemmed from observed emissions from components atop the South tank battery.
DIGITAL SIGNATURES
VICTORIA
Digitally signed by VICTORIA NELSON
Date: 2022.10.25
Report Author: _N_E__L_S_O__N_____1_6:_16_:2_8 _-0_5'0_0'_____________
SARAH
Digitally signed by SARAH MARSHALL
Date: 2022.10.26
Section Supervisor: _M_A__R_S__H_A__L_L__1_0:_01_:4_5_-0_5'0_0_' _____________
Page 3 of 5
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Jacob Herbers
2. Archival Record Location: Region 5 Electronic Records Center
Image # 1 2 3 4 5 6 7
File Name IMG_0189.JPG IMG_0190.JPG IMG_0191.JPG IMG_0192.JPG IMG_0193.JPG IMG_0194.JPG IMG_0195.JPG
8
IMG_0196.JPG
9
IMG_0197.JPG
10
IMG_0198.JPG
11
IMG_0199.JPG
12
IMG_0200.JPG
13
IMG_0201.JPG
14
IMG_0202.JPG
15
IMG_0203.JPG
Date and Time 2022:08:29 14:04:35 EDT 2022:08:29 14:04:52 EDT 2022:08:29 14:05:13 EDT 2022:08:29 14:05:26 EDT 2022:08:29 14:07:50 EDT 2022:08:29 14:09:17 EDT 2022:08:29 14:10:14 EDT
2022:08:29 14:12:09 EDT
2022:08:29 14:19:07 EDT 2022:08:29 14:23:32 EDT 2022:08:29 14:23:51 EDT 2022:08:29 14:28:00 EDT
2022:08:29 14:28:15 EDT
2022:08:29 14:32:39 EDT 2022:08:29 14:39:04 EDT
Description of Image Wells 1H-3H South tank battery Combustors South tank battery West combustors South tank battery Nameplate Thief hatch with oily residue on Tank 2H of the South tank battery Thief hatch with oily residue on Tank 2H of the South tank battery South tank battery North tank battery North tank battery nameplate Thief hatch on center tank of the North tank battery Thief hatch on West tank of the North tank battery GPUs and sand traps GPUs and compressor
APPENDIX B: DIGITAL VIDEO LOG
1. Inspector Name: Victoria Nelson, Sasha Letuchy
2. Archival Record Location: Region 5 Electronic Records Center
Video # File Name
1
MOV_2803.mp4
2
MOV_2634.mp4
3
MOV_2804.mp4
4
MOV_2635.mp4
5
MOV_2805.mp4
6
MOV_2636.mp4
7
MOV_2637.mp4
Date & Time 8/29/22 14:03 EDT
8/29/22 14:05 EDT 8/29/22 14:07 EDT
8/29/22 14:08 EDT 8/29/22 14:09 EDT
8/29/22 14:10 EDT 8/29/22 14:29 EDT
Description of Video Emissions from pipe off the header line on condensate tank 3H of the South tank battery Tank 2H Emissions from thief hatch on produced water Tank 2H of the South tank battery Top of south tank battery Emissions from conservation vent on produced water Tank 3H of the South tank battery Combustors Sand traps and heater treaters
Page 4 of 5
8
MOV_2806.mp4 8/29/22 14:30 EDT Portable compressor next to GPUs
9
MOV_2807.mp4 8/29/22 14:33 EDT Emissions from South heater treater
10
MOV_2638.mp4 8/29/22 14:33 EDT Indirect fired heater condensate
stabilizer - two stacks
11
MOV_2808.mp4 8/29/22 14:36 EDT Combustor #3/4 of the North combustor
set
12
MOV_2809.mp4 8/29/22 14:37 EDT Combustor #2/2 of the South combustor
set
Page 5 of 5