Document Lpy2k81Z2XdR1rnKdrrr06Qq7
106
Air Conditionini
MlfXliM Hayes Furnace Mfg. & Supply Co.
3233 South LaCienega Blvd., Los Angeles 16, Calif.
(Telephone Texas 0-3734) Contact Nearest Representative
M. Blazer A Son, Pasaic, N. J. R. B. Holcombe, Atlanta, Ga.
Luedecke Engineering Co, Austin, Texas McCombs Supply Co, Denver, Colo.
ftiru-lttii- Heating Supplies, Ltd., Edmonton, Alberta, Canada
McDonald Mfg. Co, Dubuque, Iowa
Boyd Engineering Co, Albuquerque, New Mex, and El Paso,
Mechanical Equipment Co, Boise, Idaho
Texas R. J. Clark Equip. Co, Clearwater, Fla. Dealers Supply Co, Atlanta, Ga. Reube O. Emery, Nashville, Tenn. F A D Distributors, Salt Lake City, Utah
Frederick Co, Spokane, Wadi. General Engineering Co, Omaha, Nebr. J. C. Lewis Co, little Rock, Arkansas
Noland & Co, Newport News, Va. Nunn Electric Co, Lubbock, Texas
O'Connor-Oklahoma Co, Oklahoma City, Tulsa, Okla, and Wichita, Kansas
Smith Steam Specialty Co, Kansas City, Mo.
Central Service Co, Inc, San Jose, CaUf.
Temp Control Corp, Portland, Oregon Valesco Inc, Visalia, Calif.
DUCT FURNACES
Heat exchanger constructed of Type 321 Stabilised Stainless Steel. Non-corrosive property of heat exchanger permits instair lation downstream of cooling coils, where codes permit, or washer. Heat exchanger will not corrode when subjected to continuous ventilation during the summer season. Designed for continuous blower operation for offices, theaters, schools, churches, and factories. Air throughput in either direction. Draft Hood and Vent Manifold reversible. 15 axes, 45/100 to 675,000 Btu per hr input in 45,000 Btu increments. A.GA. certi fied for all gases.
MODEL SED-E
Non-corrosive type 321 stainless steel heat exchanger. Permits installation downstream of cooling equipment, where codes permit, for continuous blower op eration. Air through-put in either direc tion. 45,000 to 675,000 Btu input.
MODEL SED-S
Same as SED-E except controls are at the side, instead of at the end where ac cessibility requires. SED-S is available in sizes from 45,000 to 675,000 Btu input in increments of 45/XX) Btu.
Both SED-E and SED-S can be used for industrial applications for drying.
FORCED AIR FURNACE MODEL SEC
Heat exchanger constructed of identical die formed sections of type 321 stabilized stainless steel. Sections are seam and arc welded. One piece cast iron burners with drilled ports. Oversize double inlet blower. Long hour motor. Equipped with glass filters. Can furnish permanent filters at extra cost. Finished in baked silver gray. 6 sizes 70,000 to 245/XX) Btu per hr input in 35,000 Btu increments. For natural, manufactured and L-P. gases. Can be used for 0 clearance.
ALL HAYES FURNACES ARE A.G.A. APPROVED
AalMUtie Eqnlpon Co Ptred
* Hayes Furnace Mfg. & Supply Co.
DUCT FURNACE MODEL SED-VF
Tested and approved as a DUCT FURNACE--Constructed of type 321 stabilised stainlea steel. Equipped with air bypass. TTandiPig large dm per Btu input. Vent in front of-'furnace. Made in 6 sizes from 70,000 to 280,000 Btu per hr input in increments of 35,000 Btu. For natural, manufactured and LB. gases.
107
FORCED AIR SUSPENDED FURNACE, MODEL SES
Equipped to ingtall in a suspended duct system. Inlet and out let designed for sheet metal duct connection.
UNIT HEATER MODEL SEU
Used where room air is to be recirculated. Diffuser outlet with adjustable vertical and horizontal vanes. Both types of Sus.pended'units are designed for factories, commercial and other large Btu requirements -- equipped with brackets for suspen sion, save floofspace. Double inlet forward curve blower. Con tinuous duty variable pitch drives; cast iron, raised port, pre cision machined burners. Made in sizes 80,000 to 480,000 Btu per hr input in 40,000 Btu increments. For natural, manufactured and LB. Gas.
EJECTAIR Power Roof Ventilator by HAYES
Centrifugal backwardly curved blower type ... the blower wheel cannot be overloaded regardless of length or curves in the duct or variation in design. It is belt driven to provide flexi bility. The ventilator is mounted on a built up curb on the roof. Special features include low profile with streamlined de sign and a corrosion resistant housing. The motor and fan bear ings are grease packed ball bearings and are out of the air stream. A manually operated safety cutoff switch is provided.
DIMENSIONS
Unit Size A B C D
1000 1200 1300 1600 1800 2000 2200 2400 2700 3000 3300 3600 4000 4400 4000 5400
24H 28 29 35* 39* 43 46*
m .55*
60* ' 66
75 85 90* 98* 108
.15* 17* 24* 25* 27* 30 30* 32* 34*
36* 40 42* 45* 49 54 57*
m 12
13* 16* 20 20 22*
25
28 31 33*
0R
40 44* 50 55
19* 21 21
24* 28 28 30* 33 36
39 41 48* 52 56 62 67
E SkSpTwt.
16 130 16 137 16 180 16 275 16 300 16 325 16 350 16 500 16 590 16 630 16 700 16 795 16 875 16 1120 16 1500 16 1900
X